Type MTE
Product Description
7
Note: The following pages
7
provide listings for most standard
transformer ratings and styles.
For other ratings or styles not
7
shown, or for special enclosure
types (including stainless steel),
refer to Eaton.
7
●
7
Epoxy-encapsulated coils
7
7
7
7
7
7
7
7
7
Application Description
Transformers provide
stepped-down voltages to
machine tool control devices,
enabling control circuits to
be isolated from all power
and lighting circuits. This
allows the use of grounded
or ungrounded circuits that
are independent of the power
or lighting grounds; thus,
greater safety is afforded
the operator. The control
transformer line is particularly
adaptable on applications
where compact construction
is demanded.
Note: The MTG “open core-coil
design” has been superseded by
the epoxy-encapsulated core-coil
design MTE with no change to
dimensions or functionality.
Contents
Description Page
Type MTE
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T7-5
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-10
Technical Data and Specifications. . . . . . . . . . . V7-T7-10
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-11
Type MTK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-13
CE Marked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-18
Type AP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-25
Features, Benefits
and Functions
●
Epoxy encapsulated
●
Laminations of high-quality
silicon steel to minimize
core losses and optimize
performance
●
Copper magnet wire for
high-quality, efficient
operation
●
Secondary fuse clips
where applicable
●
Optional primary fusing
●
Molded in terminals
●
50/60 Hz operation
●
130°C insulation
system standard
●
Performance meets/
exceeds requirements
of ANSI/NEMA ST-1
●
Regulation exceeds
ANSI/NEMA requirements
for all ratings
●
25–1500 VA ratings
●
Molded-in terminals for
maximum durability
Standards and Certifications
●
UL listed
●
cUL listed
●
RoHS compliant
Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards. All
600 volt class transformers
are UL listed unless
otherwise noted.
7
7
7
7
7
7.1
Industrial Control Transformers
Tra ns for m er s
7
7
7
7
7
7
7
7
7
7
7
CE Marked
Product Description
7
Note: The following pages
7
provide listings for most standard
transformer ratings and styles.
For other ratings or styles not
7
shown, or for special enclosure
types (including stainless steel),
refer to Eaton.
7
Application Description
7
Transformers provide steppeddown voltages to machine
7
tool control devices, enabling
control circuits to be isolated
7
from all power and lighting
circuits. This allows the use
7
of grounded or ungrounded
circuits that are independent
of the power or lighting
7
grounds; thus, greater safety
is afforded the operator. The
7
control transformer line is
particularly adaptable on
7
applications where compact
construction is demanded.
7
7
Features, Benefits
and Functions
Type MTE
●
Epoxy encapsulated
coil design
●
Copper magnet wire for
high-quality, efficient
operation
●
Laminations of high-quality
silicon steel to minimize
core losses and optimize
performance
●
Molded-in terminals
●
50/60 Hz operation
●
130°C insulation
system standard
●
Performance meets/
exceeds requirements of
ANSI/NEMA ST-1
●
Regulation exceeds
ANSI/NEMA requirements
for all ratings
●
Non-short circuit-proof
transformer, isolation type
Contents
Description Page
Type MTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-4
Type MTK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-13
CE Marked
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T7-19
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-21
Technical Data and Specifications. . . . . . . . . . . V7-T7-21
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-22
Type AP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-25
Standards and Certifications
●
UL listed
●
Type MTK
●
Epoxy resin-impregnated
coil design
●
Copper magnet wire for
high-quality, efficient
operation
●
50/60 Hz operation
●
180°C insulation system
●
Performance meets/
exceeds requirements
of ANSI/NEMA ST-1
●
Regulation exceeds
ANSI/NEMA requirements
for all ratings
●
500–5000 VA ratings
cUL listed
●
CE Marked units comply
with IEC EN-61558-2
●
RoHS compliant
Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards. All
600 volt class transformers
are UL listed unless
otherwise noted.