Cutler Hammer, Div of Eaton Corp Industrial Control Transformers Catalog Page

7.1
Type MTE Transformer
Industrial Control Transformers
Tra ns for m er s
7
7
7
7
7
7
7
7
7
7
7
Type MTE
Product Description
7
Note: The following pages
7
provide listings for most standard transformer ratings and styles. For other ratings or styles not
7
shown, or for special enclosure types (including stainless steel), refer to Eaton.
7
7
Epoxy-encapsulated coils
7
7
7
7
7
7
7
7
7
Application Description
Transformers provide stepped-down voltages to machine tool control devices, enabling control circuits to be isolated from all power and lighting circuits. This allows the use of grounded or ungrounded circuits that are independent of the power or lighting grounds; thus, greater safety is afforded the operator. The control transformer line is particularly adaptable on applications where compact construction is demanded.
Note: The MTG “open core-coil design” has been superseded by the epoxy-encapsulated core-coil design MTE with no change to dimensions or functionality.
Contents
Description Page
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T7-5
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-10
Technical Data and Specifications. . . . . . . . . . . V7-T7-10
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-11
Type MTK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-13
CE Marked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-18
Type AP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-25
Features, Benefits and Functions
Epoxy encapsulated
Laminations of high-quality silicon steel to minimize core losses and optimize performance
Copper magnet wire for high-quality, efficient operation
Secondary fuse clips where applicable
Optional primary fusing
Molded in terminals
50/60 Hz operation
130°C insulation system standard
Performance meets/ exceeds requirements of ANSI/NEMA ST-1
Regulation exceeds ANSI/NEMA requirements for all ratings
25–1500 VA ratings
Molded-in terminals for maximum durability
Standards and Certifications
UL listed
cUL listed
RoHS compliant
Industry Standards
All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted.
7
7
7
7
7
7.1
Type MTE CE-Marked CPT
Industrial Control Transformers
Tra ns for m er s
7
7
7
7
7
7
7
7
7
7
7
CE Marked
Product Description
7
Note: The following pages
7
provide listings for most standard transformer ratings and styles. For other ratings or styles not
7
shown, or for special enclosure types (including stainless steel), refer to Eaton.
7
Application Description
7
Transformers provide stepped­down voltages to machine
7
tool control devices, enabling control circuits to be isolated
7
from all power and lighting circuits. This allows the use
7
of grounded or ungrounded circuits that are independent of the power or lighting
7
grounds; thus, greater safety is afforded the operator. The
7
control transformer line is particularly adaptable on
7
applications where compact construction is demanded.
7
7
Features, Benefits and Functions
Type MTE
Epoxy encapsulated coil design
Copper magnet wire for high-quality, efficient operation
Laminations of high-quality silicon steel to minimize core losses and optimize performance
Molded-in terminals
50/60 Hz operation
130°C insulation system standard
Performance meets/ exceeds requirements of ANSI/NEMA ST-1
Regulation exceeds ANSI/NEMA requirements for all ratings
Non-short circuit-proof transformer, isolation type
Contents
Description Page
Type MTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-4
Type MTK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-13
CE Marked
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T7-19
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-21
Technical Data and Specifications. . . . . . . . . . . V7-T7-21
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-22
Type AP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T7-25
Standards and Certifications
UL listed
Type MTK
Epoxy resin-impregnated coil design
Copper magnet wire for high-quality, efficient operation
50/60 Hz operation
180°C insulation system
Performance meets/ exceeds requirements of ANSI/NEMA ST-1
Regulation exceeds ANSI/NEMA requirements for all ratings
500–5000 VA ratings
cUL listed
CE Marked units comply with IEC EN-61558-2
RoHS compliant
Industry Standards
All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted.
Catalog Number Selection
Please refer to Page V7-T7-3.
7
7
7
7
7
7
V7-T7-18 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—July 2015 www.eaton.com
Loading...