CTEK battery charger, 1075 User Manual

EN
EN • 3
MODE
RECONDAGM
12V/5A
MXS 5.0
to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest technology in battery charging.
CTEK COMFORT CONNECT – eyelet M6
CTEK COMFORT CONNECT
MAINS CABLE
CTEK COMFORT CONNECT – clamp
CHARGE CABLE
SUPPLY PLUG*
* Supply plugs may differ to suit your wall socket.
SMALL
BATTERY
PROGRAM
ERROR LAMP
NORMAL
BATTERY
PROGRAM
FULLY CHARGEDREADY TO USE
AGM
OPTION
RECOND OPTION
POWER LAMP
HOW TO CHARGE
1. Connect the charger to the battery.
2. Connect the charger to the wall socket. The power lamp will indicate that the mains cable is connected to the wall socket. The error lamp will indicate if the battery clamps are incorrectly connected. The reverse polarity protection will ensure that the battery or charger will not be damaged.
3. Press the MODE-button to select charging program.
SMALL BATTERY PROGRAM NORMAL BATTERY PROGRAM
Continue to press the MODE-button to combine charging program with charging options.
AGM OPTION
RECOND OPTION
Press the MODE-button several times until the desired combination of charging program and options are lit.
4. Follow the 8 -step display through the charging process. The battery is ready to start the engine when STEP 4 is lit. The battery is fully charged when STEP 7 is lit.
5. Stop charging at any time by disconnecting the mains cable from the wall socket.
MODE BUTTON
MANUAL
AGM
4 • EN
BATTERY SIZE (Ah)
TIME TO 80% CHARGED
2Ah
2h
8Ah
8h
20Ah
4h
60Ah
12h
110Ah 26h
READY TO USE
The table shows the estimated time for empty batter y to 80% charge.
CHARGING PROGRAMS
Settings are made by pressing the MODE-but ton. After about two seconds the charger acti­vates the selected program. The selected program will be restarted next time the charger is connected.
The table explains the different Charging Programs:
Program
Battery
Size (Ah)
Explanation Temp range
1. 2–14 Ah
Small battery program
14.4V/0.8A Use for smaller batteries.
-2 0°C–+5 0°C
(-4ºF–122ºF)
14–16 0Ah
Normal battery program
14.4 V/5A Use for WE T batteries, Ca/Ca, MF, GEL batteries and many AGM batteries.
-2 0°C–+5 0°C
(-4ºF–122ºF)
14–16 0Ah
AGM option
14.7 V/5A Use for charging most AGM batt ­eries like Optima and Odyssey.
-2 0°C–+5 0°C
(-4ºF–122ºF)
RECOND
14–16 0Ah
Recond option 15.8V/1.5A Use to return energy to the empty WET and Ca/Ca batteries. Recond your battery once per year and after deep discharge to maximise lifetime and capacity. The Recond program adds STEP 6 to the normal battery
program.
-2 0°C–+5 0°C
(-4ºF–122ºF)
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the battery´s positive pole?
2. Is the charger connected to a 12V batter y?
3. Has charging been interrupted in STEP 1, 2 or 5?
Restart the charger by pressing the MODE-button. If charging is still being interrupted, the battery...
STEP 1: ...is seriously sulphated and may need to be replaced. STEP 2 : ...can not accept charge and may need to be replaced. STEP 5: ...can not keep charge and may need to be replaced.
AGM
POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT
The charger has entered the energy save mode. This happens if the charger isn't connected to a battery in 2 minutes.