4 • EN
BATTERY SIZE (Ah)
TIME TO 80% CHARGED
2Ah
2h
8Ah
8h
20Ah
4h
60Ah
12h
110Ah 26h
READY TO USE
The table shows the estimated time for empty batter y to 80% charge.
CHARGING PROGRAMS
Settings are made by pressing the MODE-but ton. After about two seconds the charger activates the selected program. The selected program will be restarted next time the charger
is connected.
The table explains the different Charging Programs:
Program
Battery
Size (Ah)
Explanation Temp range
1. 2–14 Ah
Small battery program
14.4V/0.8A
Use for smaller batteries.
-2 0°C–+5 0°C
(-4ºF–122ºF)
14–16 0Ah
Normal battery program
14.4 V/5A
Use for WE T batteries, Ca/Ca,
MF, GEL batteries and many
AGM batteries.
-2 0°C–+5 0°C
(-4ºF–122ºF)
14–16 0Ah
AGM option
14.7 V/5A
Use for charging most AGM batt eries like Optima and Odyssey.
-2 0°C–+5 0°C
(-4ºF–122ºF)
RECOND
14–16 0Ah
Recond option 15.8V/1.5A
Use to return energy to the empty
WET and Ca/Ca batteries.
Recond your battery once per
year and after deep discharge to
maximise lifetime and capacity.
The Recond program adds
STEP 6 to the normal battery
program.
-2 0°C–+5 0°C
(-4ºF–122ºF)
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the battery´s
positive pole?
2. Is the charger connected to a 12V batter y?
3. Has charging been interrupted in STEP 1, 2 or 5?
Restart the charger by pressing the MODE-button. If charging is still
being interrupted, the battery...
STEP 1: ...is seriously sulphated and may need to be replaced.
STEP 2 : ...can not accept charge and may need to be replaced.
STEP 5: ...can not keep charge and may need to be replaced.
AGM
POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT
The charger has entered the energy save mode. This happens if the
charger isn't connected to a battery in 2 minutes.