EN
EN • 3
CONGRATULATIONS
on the purchase of your new professional switch mode battery charger. This charger is
included in a series of professional chargers from CTEK SWEDEN AB and represents the
latest technology in batter y charging.
CTEK COMFORT CONNECT – eyelet M6
CTEK COMFORT CONNECT
MAINS CABLE
CTEK COMFORT CONNECT – clamp
CHARGE CABLE
SUPPLY PLUG*
* Supply plu gs may d iffer to suit you r wall socket.
SMALL
BATTERY
PROGRAM
ERROR LAMP
NORMAL
BATTERY
PROGRAM
FULLY CHARGEDREADY TO USE
COLD
WEATHER
PROGRAM
POWER LAMP
HOW TO CHARGE
1. Connect the charger to the batter y.
2. Connect the charger to the wall socket. The power lamp will indicate that the mains
cable is connected to the wall socket. The error lamp will indicate if the battery clamps
are incorrectly connected. The reverse polarity protection will ensure that the battery
or charger will not be damaged.
3.Press the MODE-button to select charging program.
4. Follow the 7-step display through the charging process.
The battery is ready to start the engine when STEP 4 is lit.
The battery is fully charged when STEP 6 is lit.
5. Stop charging at any time by disconnecting the mains cable from the wall socket.
MODE BUTTON
MANUAL
MODE

4 • EN
BATTERY SIZE (Ah)
TIME TO 80% CHARGED
2Ah
2h
8Ah
8h
20Ah
5h
60Ah
15h
80Ah
20h
READY TO USE
The table shows the estimated time for empt y battery to 80% charge
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about t wo seconds the charger
activates the selected program. The selected program will be restarted next time the
charger is connected.
The table explains the different Charging Programs:
Program
Battery
Size (Ah)
Explanation Temp range
1. 2–14Ah
Small battery program
14.4V/0.8A
Use for smaller batteries.
-2 0°C –+50°C
(-4ºF–122ºF)
14–13 0 A h
Normal bat ter y program
14.4V/3.8A
Use for WE T batteries, Ca/Ca,
MF, GEL batteries and many
AGM batteries.
+5°C–+50°C
(41ºF–122ºF)
14–13 0 A h
Cold weather program
14.7V/3.8A
Use for charging at low temperatures and for power AGM batteries like Optima and Odyssey.
-2 0°C –+5°C
(-4ºF–41ºF)
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the battery´s
positive pole?
2. Is the charger connected to a 12V battery?
3. Has charging been interrupted in STEP 1, 2 or 5?
Restart the charger by pressing the MODE-button. If charging is still
being interrupted, the battery...
STEP 1: ...is seriously sulphated and may need to be replaced.
STEP 2 : ...can not accept charge and may need to be replaced.
STEP 5: ...can not keep charge and may need to be replaced.
POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT:
The charger has entered the energy save mode. This happens if the
charger isn´t connected to the battery in 2 minutes.