Data Express DE200i-S Data Express DE200i-S
Certification
EMI Standard: FCC Part 15 Class B, CE CISPR B, C-Tick
EMC Standard: EN55022, EN50081, EN50082
FCC Certification
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received; including interference that may cause undesired
operation.
CE and C-Tick Notice
The official CE and C-Tick symbols indicate compliance of this StorCase product to the EMC directive of the European
Community and Australian Communications Authority respectively.
Declarations of CE and C-Tick Conformity in accordance with the required standards have been made and are on file at
StorCase Technology; a copy of Declaration of Conformity is available in the full version of the product users guide.
LIMITED WARRANTY
Duration of Warranty
Seven-Year Warranty: The following StorCase products are covered by this warranty for a period of seven (7) years from the
original date of purchase from StorCase or its authorized reseller: all Data Express® removable device enclosures and all
StorCase interface cables and accessories specifically intended for use with these products. Data Silo®, Data Stacker® and
InfoStation® products are covered by this warranty for a period of seven (7) years, excepting the RAID controller, power supply, fan
and blower components, which are covered by the three-year warranty described below.
Three-Year Warranty: The following StorCase products are covered by this warranty for a period of three (3) years from the
original date of purchase from StorCase or its authorized reseller: all Rhino®JR external expansion chassis, all RhinoJR
removable drive enclosures, and all RAID controller modules. In addition, the following components of the Data Express, Data Silo,
Data Stacker, InfoStation products are subject to warranty for a period of three (3) years: all power supplies, fans and blowers.
Warranty Claim Requirements
To obtain warranty service, the defective product must be returned to your local authorized StorCase dealer or distributor, or, with
prior StorCase approval, to the StorCase factory service center. For defective product returns directly to StorCase, a Return
Material Authorization ("RMA") number must be obtained by calling StorCase Customer Service at (714) 445-3455.
Free Technical Support
StorCase Technical Support can be reached in the U.S. at (714) 438-1858 or toll-free at (888) 435-5460 (U.S. and Canada only).
StorCase European Technical Support can be reached in the U.K. at +44 (0) 1932 738900.
Disclaimers
The foregoing is the complete warranty for the products identified above and supersedes all other warranties and
representations, whether oral or written. StorCase expressly disclaims all warranties for the identified products, which
are not stated herein, including, to the extent permitted by applicable law, any implied warranty of merchantability or
fitness for a particular purpose. In no event will StorCase be liable to the purchaser, or to any user of a StorCase
product, for any damages, expenses, lost revenues, lost savings, lost profits, or any other incidental or consequential
damages arising from the purchase, use or inability to use a StorCase product, even if StorCase has been advised of
the possibility of such damages.
Complete warranty statement can be found in the full version of the Users Guide or on the StorCase web site at:
http://www.storcase.com/company/warranty.asp
Copyright © 2004 StorCase Technology. All rights reserved. All registered trademarks are the property of
StorCase Technology. All other logos and trademarks are properties of their respective companies. Printed
in the U.S.A.
DE200i-S
Removable SCSI Narrow
Single-Ended Drive Enclosure
This document is not intended to replace the DE200i-S Users Guide. A full version of the Users Guide
can be found on the StorCase website at http://www.storcase.com/support/dataexpress.asp
Cable
Cover
(Provided)
Disk Drive
(Not Included)
Power Cable
I/O Cable
ID Select
Cable
Drive Installation Assembly
Receiving
Frame
ID Select Pins (J4): Pins 1-14 are reserved. Pins 15 -20 provide unit SCSI ID selection for the computer system or expansion chassis. For remote ID selection through an expansion chassis, the unit
ID must be set to 0 or open (no jumpers installed) on these pins.
Enable Termination Power to/from SCSI Bus (W1): The rear panel contains the bus terminators (active) for 8-bit single-ended SCSI interface. Jumper is installed at the factory.
Onboard (Receiving Frame) Termination (W2): Position A is installed at the factory and will disable
termination. Moving the jumper to position B will enable onboard termination.
(Rear View)
Receiving Frame Motherboard
Drive Carrier
0366a
#6-32 x 3/16
Phillips Flat HD
Screw (6 Total)
StorCase Technology, Inc. D89-0000-0142 Rev. B00 D89-0000-0142 Rev. B00 StorCase Technology, Inc.

Installed
Ground
From System ID0
From System ID1
From System ID2
(J4) Pin Configuration
at Factory
19
20
214
113
Receiving Frame
Mother Board
Connector J4
0427
Reserved
Receiving Frame Connector
Typical 2mm Drive Pin Configuration
Figure below illustrates a typical SCSI ID select connection to a drive with 2mm ID select pins. Attach
the ID select cable to the drive using the 2mm connectors. Align the ID0 pin with the black wire. Attach
the 1.25mm connector on the other end of the ID select cable to the 1.25mm connector (J3B) provided
on the signal distribution board, located inside the carrier. In most cases, the drive manufacturer labels
the rows of SCSI ID select pins in their significant bit order (0, 1, 2, as shown in figure below). In other
cases, the manufacturer does not clearly label these pins in their significant bit order, but instead uses
pin numbers only. The wires on the wire harness connect to the positive pin (or sig-nal pins) on the disk
drive. In any case, either the odd numbered row of pins or the even numbered row of pins will be the
signal row. Refer to the device manufacturer's documentation for additional pin numbering and jumper option information.
Data Express DE200i-S Data Express DE200i-S
Typical 1.25mm Drive Pin Configuration
Figure below illustrates a typical SCSI ID select connection to a drive with 1.25mm ID select pins. Connect
the 1.25mm ID select cable connector to the drive ID select pins. Attach each of the 2mm connectors on
the other end of the ID select cable to the 2mm connectors (J3A) provided on the signal distribution board,
located inside the carrier. Align the ID0 pin with the black wire of the cable. Refer to the device
manufacturer's documentation for additional pin numbering and jumper option information.
Signal Distribution Board
ID
Select
(1.25mm Drive Pins)
Typical SCSI ID Select Connections
1.25mm SCSI ID
Selection Connector J5
(located on disk drive
PCB)
G
A2
n
A1
d
A0
R
e
s
e
r
v
e
d
Cable
SCSI ID Select
Cable (from Data
Express Signal
Distribution Board)
Red (ID2)
Brown (ID1)
Black (ID0)
When Using J5,
Remove All
Jumpers From JP1
Inside Carrier
CARRIER BOARD
2mm Data Express
ID Select Interface
(J3A)
1.25mm Data
Express ID Select
Interface (J3B)
CARRIER
BOARD
J6
(Reserved)
2mm Data Express
ID Select Interface
(J3A)
1.25mm Data
Express ID Select
Interface (J3B)
J3
Typical 2mm Drive ID Select Pins
(Pins vary on each drive model. See
Drive Manufacturer's Information.)
DISK DRIVE
Signal Distribution
Board
ID
Select
Cable
Red (ID2)
Brown (ID1)
Black (ID0)
(2mm Drive Pins)
Typical SCSI ID Select Connections
Carrier
To Drive ID
Select Pins
To ID
To ID
To ID
2
1
3-PIN WIRE WRAP
CONNECTOR (Provided). Use
0
in place of ID select cable
if there is not enough space.
Connects to J3.
Pin 1
0426
StorCase Technology, Inc. D89-0000-0142 Rev. B00
Power
Connector
SCSI I/O
Connector
SCSI ID Selection Pins
JP1 (located on disk
drive PCB)
0416
Selecting the Unit ID Number: Use the alignment tool (provided) to select the ID number of the disk
drive.
Unit
Number
Display
Lock
and DC
Power
Switch
Front of
Unit
Drive
Carrier
(removed)
0363
Unit ID Select Switch Location
Receiving
Frame
Drive
Carrier
Guide
Unit Select
Rotating
Switch
NOTE: The lock on the Data Express receiving frame functions as a lock and a DC power switch for
the carrier unit. The lock MUST be engaged (turned counterclockwise) in order to supply power
to the carrier and installed drive unit.
D89-0000-0142 Rev. B00 StorCase Technology, Inc.