Rugged, Reliable, Mobile, Secure
DE110 SATA 3Gb/s Install Guide
Removable SATA 3Gb/s Drive Enclosure
NOTE:
DE110 SATA 3Gb/s receiving frames support both SATA 3Gb/s
and DE110 SATA 3Gb/s carriers.
DE110 SATA 1.5Gb/s “universal’ receiving frames support
DE110 SATA 1.5Gb/s and DE110 PATA carriers.
For SATA 3Gb/s operation, a SATA 3Gb/s controller and SATA
3Gb/s drive are required.
Receiving Frame Motherboard
I/O Connector (JP1)
The input/output connector provides a standard interface for all
SATA signals.
SATA Power Connector (P1)
15-Pin SATA power connector to accept DC power.
Installation
1. Remove the drive cover from the carrier.
2. Carefully insert the drive into the carrier. Slide the drive
3. Fasten the drive into place with four (4) #6-32 Phillips Flat
TM
towards the Drive Carrier Board, so that the I/O connector on
the drive mates with the connector on the Drive Carrier Board.
Turn the drive/carrier assembly over.
Head screws. Some drives may require minor adjustment
before securing into carrier with screws.
NOTE: If your system does not accommodate the SATA
power connector, use a SATA-to-DC Power adapter cable
(sold separately) to connect to your system’s DC power.
Drive Activity LED Pin (JACT1)
Pin 1 is used for host connection (cable not included) to the Drive
Activity LED. Some SATA PC systems/host controllers provide
support for the Drive Activity LED feature (refer to the SATA PC
system/host controller manufacturer’s documentation for further
information).
Factory Reserved Pins
These pins are reserved for factory use only - Do not install
jumper under any circumstances!
= Pin 1
Drive Activity
LED Pin
Reserved SATA Power
Connector
(P1)
Figure 1: Receiving Frame Motherboard (rear view)
I/O Connector
(J1)
4. Install the drive cover and secure with two (2) #6-32 Phillips
Flat Head screws (provided).
SATA Drive
(not included)
Drive Carrier
Board
Drive Carrier
#6-32 Phillips
Flat Head Screw
(4 each)
Figure 2: Drive Installation Assembly
1-800-260-9800 www.CRU-DataPort.com
Rugged, Reliable, Mobile, Secure
TM
Drive Activity LED
NOTE: Some SATA PC systems/host controllers provide
support for the Drive Activity LED feature (refer to the SATA
PC system/host controller manufacturer’s documentation for
further information).
The Drive Activity LED can be enabled via host connection (cable
not included) to Pin 1 located on the Receiving Frame Motherboard (Figure 1).
Refer to the SATA PC system/host controller manufacturer’s
documentation for further information.
Spacer Plates (Optional)
The DE110 SATA 3Gb/s enclosure is designed to fit most comput-
er systems with standard 5.25” peripheral slots. The installation
of the spacer plates (provided) may or may not be necessary.
NOTE: Depending on the computer system, spacer plates
may be positioned on the receiving frame to utilize either
top or bottom row of side-mounting holes.
Unit ID Select Switch Settings
NOTE: The unit ID number display is for ID display pur-
poses only.
The following table lists the Unit ID Select Switch settings.
Selecting the Unit ID Number
Use the alignment tool (provided) to select the ID number of the
disk drive.
Drive Carrier
Guide
Switch Location
Figure 5: Unit ID Select
Typical Data Express
Receiving Frame
NOTE: The lock on the Data Express serves as a power
switch. It must be engaged (turned counterclockwise) for the
Data Express to power up and function properly.
Limited Product Warranty
CRU-DataPort (CRU) warrants the Data Express DE110 to be free of significant
defects in material and workmanship for a period of five years from the original
date of purchase. CRU’s warranty is nontransferable and is limited to the
original purchaser.
Limitation of Liability
The warranties set forth in this agreement replace all other warranties. CRU expressly
disclaims all other warranties, including but not limited to, the implied warranties of
merchantability and fitness for a particular purpose and non-infringement of third-party
rights with respect to the documentation and hardware. No CRU dealer, agent or employee is authorized to make any modification, extension, or addition to this warranty.
In no event will CRU or its suppliers be liable for any costs of procurement of substitute
products or services, lost profits, loss of information or data, computer malfunction, or
any other special, indirect, consequential, or incidental damages arising in any way out
of t
he sale of, use of, or inability to use any CRU product or service, even if CRU has
been advised of the possibility of such damages. In no case shall CRU’s liability exceed
the actual money paid for the products at issue. CRU reserves the right to make modifications and additions to this product without notice or taking on additional liability.
Unit ID Select
Rotating Switch
Figure 3: Unit ID Display Hex Reference
Certification
EMI Standard: FCC Part 15 Class B, CE
EMC Standard: EN55022, EN55024
FCC Certification
This device has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received; including interference that
may cause undesired operation.
Register your product at www.CRU-DataPort.com
A7-110-0007 Rev. 1.1
1-800-260-9800 www.CRU-DataPort.com