1718 W. Mishawaka Road
Elkhart, Indiana 46517 U.S.A.
European Representative's Name and Address:
Nick Owen
19 Clos Nant Coslech
Pontprennau
Cardiff
CF23 8ND United Kingdom
Equipment Type: Commercial Audio Power Amplifiers
Family Name: Xs
Model Names: Xs4300, Xs1200, Xs900, Xs700, Xs500
EMC Standards:
EN 55103-1:1995 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 1: Emissions
EN 55103-1:1995 Magnetic Field Emissions-Annex A @ 10 cm and 1 M
EN 61000-3-2:1995+A14:2000 Limits for Harmonic Current Emissions (equipment input current ≤16A per phase)
EN 61000-3-3:1995 Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems Rated Current ≤16A
EN 55022:1992 + A1: 1995 & A2:1997 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE: Radiated, Class B Limits; Conducted, Class B
EN 55103-2:1996 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 2: Immunity
EN 61000-4-2:1995 Electrostatic Discharge Immunity (Environment E2-Criteria B, 4k V Contact, 8k V Air Discharge)
EN 61000-4-3:1996 Radiated, Radio-Frequency, Electromagnetic Immunity (Environment E2, criteria A)
EN 61000-4-4:1995 Electrical Fast Transient/Burst Immunity (Criteria B)
EN 61000-4-5:1995 Surge Immunity (Criteria B)
EN 61000-4-6:1996 Immunity to Conducted Disturbances Induced by Radio-Frequency Fields (Criteria A)
EN 61000-4-11:1994 Voltage Dips, Short Interruptions and Voltage Variation
Safety Standard:
EN 60065: 1998 Safety Requirements - Audio Video and Similar Electronic Apparatus
I certify that the product identified above conforms to the requirements of the EMC Council Directive 89/336/EEC as amended by 92/31/EEC, and the Low Voltage Directive 73/23/EES as amended by 93/68/EEC.
Signed
Larry Coburn
Title: Senior Vice President of Manufacturing
DECLARATION of CONFORMITY
Sue Whitfield
574-294-8289
swhitfield@crownintl.com
Date of Issue: March 1, 2003
Operation Manual
Due to line current harmonics, we recommend that you contact your supply authority before connection.
page 3
Table of Contents
Xs Series Power Amplifiers
Important Safety Instructions ...........................................................2
Declaration of Conformity ................................................................3
*1 kHz Power: refers to maximum average power
in watts at 1kHz with 0.15% THD.
** at 0.5% THD.
Power*
1,900W**
1,645W
1 kHz
Power*
1,200W**
900W
2,500W**
2,100W
1 Welcome
The Xs Series of power amplifiers from Crown®
represents a new era in affordable, quality
power amplification. The line consists of five
models: four 2-channel units and one 4-channel unit, each in a uniform, rugged chassis. The
Xs Series incorporates the best of tried-andtrue design principles and innovative features.
Modern power amplifiers are sophisticated
pieces of engineering capable of producing
extremely high power levels. They must be
treated with respect and correctly installed if
they are to provide the many years of reliable
service for which they were designed.
In addition, Xs Series amplifiers include a
number of features which require some explanation before they can be used to their maximum advantage.
Please take the time to study this manual so
that you can obtain the best possible service
from your amplifier.
• 2-channel models have touch-proof binding
post outputs, Speakon
inputs, and electronically balanced XLR-1/4"
combo inputs with daisy-chain XLR outputs.
Xs4300 has XLR-1/4" combo inputs and
touch-proof binding post outputs.
• Features precision detented level controls,
power switch, and eight LEDs which indicate
signal and clip for each channel, AC mains,
power, bridge mode, temperature and fault conditions.
• Microprocessor-controlled protection system.
• Three-Year, No-Fault, Fully Transferable
Warranty completely protects your investment
and guarantees its specifications.
*1 kHz Power: refers to maximum average power
in watts at 1kHz with 0.15% THD.
®
outputs, Phoenix-style
1 kHz
Power*
300W
700W
1.2 How to Use This Manual
This manual provides you with the necessary
information to safely and correctly setup and
operate your amplifier. It does not cover every
aspect of installation, setup or operation that
might occur under every condition. For additional information, please consult Crown’s
Amplifier Application Guide (available online at
www.crownaudio.com), Crown Technical Support, your system installer or retailer.
We strongly recommend you read all instructions, warnings and cautions contained in this
manual. Also, for your protection, please send
in your warranty registration card today. And
save your bill of sale — it’s your official proof
of purchase.
Operation Manual
page 5
Xs Series Power Amplifiers
page 6
Operation Manual
Xs Series Power Amplifiers
2 Setup
2.4 Choose Input Wire
and Connectors
Crown recommends using pre-built or professionally wired balanced line (two-conductor plus shield), 22-24 gauge cables and
connectors. At the amplifier inputs, use either:
NOTE: Custom wiring should only be performed by qualified personnel.
Combo Input Connector XLR
Figure 2.3
Wiring, Balanced (Top) and
Unbalanced (Bottom)
2.5 Choose Output Wire and Connectors
Crown recommends using pre-built or professionally wired, highquality, two- or four-conductor, heavy gauge speaker wire and
connectors. You can use banana plugs, spade lugs, or bare wire
for your output connectors (Figure 2.6). Also, in the 2-channel
models, you can use a 4-pole Speakon
and Table 1). To prevent the possibility of short-circuits, wrap or
otherwise insulate exposed loudspeaker cable connectors.
Note: Binding post outputs on European models come
with safety plugs installed to prevent European powercord plugs from being inserted. The top & bottom entry
positions for these connectors should therefore be used
with European models.
Using the guidelines below, select the appropriate size of wire
based on the distance from amplifier to speaker.
Distance Wire Size
up to 25 ft. 16 AWG
26-40 ft. 14 AWG
41-60 ft. 12 AWG
61-100 ft. 10 AWG
101-150 ft. 8 AWG
151-250 ft. 6 AWG
CAUTION: Never use shielded cable for output wiring.
®
connector (Figure 2.7
Phoenix-Style Input Connector Wiring,
Figure 2.5
Balanced (Top) and Unbalanced (Bottom).
Note Jumper Between “S” and “–”
Figure 2.6
Binding Post Output Wiring for 2-Channel Models
Operation Manual
page 7
Xs Series Power Amplifiers
page 8
Operation Manual
Xs Series Power Amplifiers
Operation Manual
page 9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.