Crown Macro-Tech MA-36X12, Macro-Tech 36x12 Specifications

MA-36x12
MACRO-TECH SERIES
LEVEL LEVEL
181512
9
21
24
6
27
3
30
0
(
CH1 CH2
3600
ODEP
/
SIGNAL
IOC
)(
9
6
3
)
1200
181512
21
24
27
0
30
ENABLE
ON
OFF
he Crown Macro-Tech Series is the defi n­ing standard for amplifi er design today. No compromises, no gimmicks. Just bril-
T
liant engineering backed by superior manufac­turing, support and an unsurpassed commit­ment to quality. Like all Crown amps, the defi n­ing characteristic of the Macro-Tech Series is sonic accuracy. A tight, rock-solid low end, with smooth, detailed highs and a well-defi ned midrange. In short, the most accurate repro­duction of an audio signal you’ve ever heard. And because we put the quality of sound above all else, a Crown is the most coveted amplifi er in the business.
When it comes to manufacturing amps, our work is based on one simple fact: there are no shortcuts to quality. And our Macro-Techs have proven it time and time again in some of the most demanding applications in the world.
Developing innovative products that meet your specifi c needs is what we’re about. Our Macro­Tech 24x6 and 36x12 provide a practical solu­tion to biamplifi ed system applications such as stage moniors. Each amp combines a high­and medium-power module in a single, low­profi le unit.
For more details about the Crown Macro-Tech Series, contact the Crown Technical Support Group at 800-342-6939 or 219-294-8200. Also, visit the Crown Audio website at www.crownaudio.com.
Specifi cations
Note: Specifi cations relate to 120-volt, 60-Hz units in Stereo mode with 8-ohm loads and an input sensitivity of 26-dB gain at 1 kHz rated power unless otherwise specifi ed. Specifi ca­tions for units supplied outside the U.S.A. may vary slightly at different AC voltages and frequencies.
Power
Output Power:
Features
• Crown’s Grounded Bridge™ design delivers large voltage swings without using easily stressed output-transistor configurations like conventional amplifi ers. The results are lower distortion and superior reliability.
• Patented ODEP® (Output Device Emulation Protection) circuitry compensates for over­heating and overload to keep the amplifi er working when others would fail.
• IOC® (Input/Output Comparator) circuitry immediately alerts of any distortion exceed­ing 0.05%, providing dynamic proof of distortion-free performance.
• PIP™ (Programmable Input Processor) con­nector accepts accessory modules that tailor the amplifi er to suit specifi c applications.
Load Impedance: Safe with all types of loads,
even reactive ones. Rated for 2 to 16 ohms.
Voltage Gain to 8-ohm load at rated output at 1 kHz, maximum level setting:
Channel 1 (3600): 124.6:1 ±6% or 41.9 dB
±0.5 dB at 0.775-volt sensitivity; 69.2:1 ±6% or
36.8 dB ±0.5 dB at 1.4-volt sensitivity. Channel 2 (1200): 64:1 ±6% or 36 dB ±0.5 dB
at 0.775-volt sensitivity; 35.5:1 ±6% or 31 dB ±0.5 dB at 1.4-volt sensitivity.
20:1 ±6% or 26 dB ±0.5 dB at +26 dB sensitiv­ity.
Required AC Mains: All units require 90 watts or less at idle. Current, voltage and frequency requirements are provided on the unit’s back panel.
AC Line Connector: NEMA 5-15P.
Performance
Frequency Response: ±0.1 dB from 20 Hz to
20 kHz at 1 watt. Phase Response: ±10 degrees from 10 Hz to
20 kHz at 1 watt.
Signal-to-Noise Ratio, 20 Hz to 20 kHz:
Better than 105 dB A-weighted or 100 dB unweighted below rated full bandwidth power.
Total Harmonic Distortion (THD): At full band­width power, less than 0.05% from 20 Hz to 1 kHz increasing linearly to less than 0.1% at 20 kHz.
Intermodulation Distortion (IMD): (60 Hz and 7 kHz at 4:1) Less than 0.05% from 10 mil­liwatts to full bandwidth power.
Damping Factor: Greater than 1,000 from 10 Hz to 400 Hz.
• Convenient high- and medium-power channel design for biamplifi ed systems such as stage monitors.
• Very low harmonic and intermodulation distortion results in the best dynamic transfer function in the industry.
• Balanced 1/4-inch(6.35-mm) phone jack inputs for each channel, with balanced XLR connectors on the standard PIP-FX module.
• Full protection from shorted, open and mis­matched loads; general overheating; DC; high-frequency overloads; and internal fault conditions.
• Three Year, No-Fault, Fully-Transferable Warranty completely protects your investment and guarantees its specifi cations.
Slew Rate: (Slew rates are limited to useful
levels for ultrasonic/RF protection.) Channel 1, greater than 30 volts per microsecond; Channel 2, greater than 13 volts per microsecond.
Controls
Enable: A front-panel push button used to turn
the amplifi er on and off. Level: A front-panel 31-detent rotary control
for each channel used to control the output level.
Sensitivity: A three-position switch inside the PIP™ compartment used to select the input sensitivity for both channels: 0.775 volts or 1.4 volts for standard 1 kHz power, or a 26 dB voltage gain.
Reset: A back-panel push button for each chan­nel used to reset the circuit breaker that pro­tects each power supply.
Indicators
Enable: An amber front-panel indicator that
shows the on/off status of the low-voltage power supply.
Signal/IOC: A green front-panel indicator for each channel that fl ashes to show amplifi er output. If a channel’s output waveform differs from its input by 0.05% or more, the indicator fl ashes brightly tion provides proof of distortion-free perfor­mance.
ODEP: Each channel has an amber front panel indicator that shows thermal-dynamic energy reserve. Normally, each ODEP indicator is lit to show available reserve energy. The indicator will dim proportionally as the energy reserve for its channel descreases. In the rare event
to show distortion. This func-
ELKHART, IN 46517 MADE IN U.S.A.
SERIAL NUMBER
ELECTRONIC EQUIPMENT
000000
REG. U.S. PAT. OFF.
4,330,809 4,611,180
INTERNATIONAL, INC.
INPUTS
INPUT GROUND LIFT
LIFT
(AFFECTS PHONE INPUTS ONLY.)
CH-2 CH-1
PUSHPUSH
INPUT INPUT
(3600)(1200)
GND
UNBALANCED INPUT WIRING
GND
3
12
CH-2 OUTPUT
+
TIP
SLEEVE
CH-1 OUTPUTS
(1200)
CAUTION: TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR
BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SER­VICING TO QUALIFIED SERVICE PERSONNEL. DISCONNECT POWER CORD BEFORE REMOVING REAR P.I.P. MODULE TO ACCESS GAIN SWITCH.
ATTENTION: DBRANCHER AVANT D’OUVRIR. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO
NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
(3600)
CLASS 1 OUTPUT WIRING REQUIRED.
MA-36x12
PUSH TO RESET
S
S
E
R
P
S
E
R
100 VAC / 17.5 A / 50-60 Hz
120 VAC / 16.5 A / 60 Hz
0000
FX
S
S
E
T
T
R
P
E
E
S
E
R
Programmable Input Processor (P.I.P.)
THIS AMPLIFIER IS EQUIPPED WITH SELECTABLE INPUT SENSITIVITY. REMOVE P.I.P. MODULE TO ACCESS SENSITIVITY SWITCH.
CH-2 CH-1
BALANCED
INPUT WIRING
+
TIP
RING
SLEEVE
GND
that a channel has no reserve, its indicator will turn off and the ODEP circuitry will limit the channel’s output drive.
Input/Output
Input Connector: Two balanced ¼-inch
(6.35-mm) phone jacks on the back panel and two balanced three-pin female XLR connectors on the factory-installed PIP-FX.
Input Impedance: Nominally 20 k ohms, bal­anced. Nominally 10 k ohms, unbalanced.
Maximum Input Level: 13 volts peak. Input Sensitivity (for rated power at 1 kHz):
0.775 volt, 1.4 volts, or a 26 dB voltage gain. Output Connectors: Color-coded 5-way binding
posts (for banana plugs, spade lugs or bare wire). Channel 1 (3600) has two pair of binding posts, and Channel 2 (1200) has one pair of binding posts.
Output Impedance: Less than 10 milliohms in series with less than 2 microhenries.
DC Output Offset: (Shorted input) ±10 milli­volts.
Output Signal: Unbalanced, two-channel.
Protection
Macro-Tech amplifi ers are protected against shorted, open or mismatched loads; overloaded power supplies; excessive temperature; chain destruction phenomena; input overload damage; and high-frequency blowups. They also protect loudspeakers from input/output DC and turn-on/turn-off transients.
If unreasonable operating conditions occur, the patented ODEP circuitry will proportionally limit the drive level to protect the output transistor stages, particularly in the case of elevated tem­perature. Transformer overheating will result in a temporary shutdown of the affected channel; when it has cooled to a safe temperature, the transformer will automatically reset itself. Con­trolled slew-rate voltage amplifi ers prevent RF burnouts, and input overload protection is pro­vided by current-limiting resistance at the input.
Turn On: Four-second delay with no dangerous transients. Delay time can be changed (contact Crown’s Technical Support Group).
Accessories
Crown PIP modules including IQ-PIP modules. With the IQ-PIP-USP2 Adapter installed into the MA-36x12, the amplifi er can accept the IQ-PIP­USP2 module.
Construction
Steel chassis with durable black fi nish, alumi­num front panel with Lexan overlay, and spe­cially designed fl ow-through ventilation from front to side panels.
Cooling: Internal heat sinks with forced-air cooling for rapid, uniform heat dissipation.
Dimensions: EIA Standard 19-inch (48.3-cm) rack mount width (EIA RS-310-B), 3.5-inch (8.9-cm) height, 16-inch (40.6-cm) depth behind the mounting surface and 2.5-inch (6.3-cm) protrusion in front of the mounting surface.
Center of Gravity: Approximately 6 inches (15.2 cm) behind front mounting surface.
Shipping Weight: 59 lbs (26.8 kg).
Crown’s Three-Year, No-Fault, Fully-Transferable Warranty
Crown offers a Three-Year, No-Fault, Fully-Transferable Warranty for every new Crown ampli­fi er—an unsurpassed industry standard. With this unprecedented No-Fault protection, your new Crown amplifi er is warranted to meet or exceed original specifi cations for the fi rst three years of ownership. During this time, if your amplifi er fails, or does not perform to original specifi cations, it will be repaired or replaced at our expense. About the only things not covered by this warranty are those losses normally covered by insurance and those caused by intentional abuse. And the coverage is transferable, should you sell your amplifi er.
See your authorized Crown dealer for full warranty disclosure and details. For customers outside of the USA, please contact your authorized Crown distributor for warranty information or call 219-294-8200.
Crown International P.O. Box 1000 Elkhart, IN 46515-1000 TEL: 574-294-8200 FAX: 574-294-8FAX www.crownaudio.com
Specifi cations subject to change without prior notice. Latest infor­mation available at www.crownaudio.com.
PIP is a trademark, and Crown, IOC, Macro-Tech and ODEP are registered trademarks of Crown International. Other trademarks are the property of their respective owners. Printed in U.S.A.
© 2001 Crown Audio, Inc.
11/01 134168-1
Loading...