Crosley CLCE500FW1, CLCE500FW2, CLCE500FW4, CLCG500FW1, CLCG500FW3 Installation Guide

...
27" (69 cm) Wide LAUNDRY CENTER
Washer- Dryer
CENTRO DE LAVANDERiA de 27" (69 cm) de ancho
Lavadora - Secadora
\
iii
SUBJECT PAGE
Pre-lnstallation Requirements ........................................................................................................ 3
Electrical Requirements ................................................................................................................. 3
Water Supply Requirements ............................................................................................................ 3
Drain Requirements ...................................................................................................................... 3
Exhaust System Requirements ................................................................................................... 4
Gas Supply Requirements ............................................................................................................. 5
Location ................................................................................................................................. 5
Rough-In Dimensions ..................................................................................................................... 6
Mobile Home Installation .............................................................................................................. 7
Unpacking ........................................................................................................................ 7
Electrical Installation ..................................................................................................................... 8
Grounding Requirements ................................................................................................................ 8
3 & 4-Wire Connections .................................................................................................................. 9
Installation ................................................................................................................................. 10-11
Replacement Parts ..................................................................................................................... 11
Espahol ...................................................................................................................................... 12-20
Laundry Center Safety
Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the laundry center is installed correctly and safely. Leave these instructions near the
laundry center after installation for future reference.
NOTE: The electrical service to the laundry center must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian Electrical Code,
CSA C22.1
NOTE: The gas service to the laundry center must conform with local codes and ordinances and the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54, or in Canada, the Canadian Natural Gas and
Propane Installation Code, CSA B149.1.
NOTE: The laundry center is designed under ANSI Z21.5.1 or ANSI/UL 2158- CAN/CSA C22.2 No. 112 (latest edition) for HOME USE only. This laundry center is not recommended for commercial applications
such as restaurants or beauty salons, etc.
For your safety the information in this manual must be followed to minimize the risk of
fire or explosion or to prevent property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
o Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or area of all occupants. Immediately call your gas supplier from a
neighbor's phone.
Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department.
Installation and service must be preformed by a qualified installer, service agency or the gas supplier.
2
PRE-INSTALLATION REQUIREMENTS
Tools and Materials Required for Installation:
1. Phillips head screwdriver.
2. Channel-lock adjustable pliers.
3. Carpenter's level.
4. Flat or straight blade screwdriven
5. Duct tape.
6. Rigid or flexible metal 4 inch (10.16 cm) duct.
7. Vent hood.
8. Pipe thread sealer (Gas).
9. Ratchet with 3/8 inch (0.96 cm) socket.
ELECTRICAL REQUIREMENTS
ELECTRICLaundry Center ]
Circuit- Individual 30 amp branch circuit fused with 30 amp minimum time delay fuses or circuit breakers.
POWER SUPPLY- 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.
POWER SUPPLY CORD KIT- The laundry center MUST employ a 3-condutor power supply cord NEMA 10-30 type SRDTrated at 240 volt AC minimum, 30 amp, with 3 open end spade lug connectors with upturned ends or closed loop connector OR a 4-condutor power supply cord NEMA 14-30 type SRDTor ST(as required) rated at 240 volt AC minimum, 30 amp, with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. If being
installed in a new branch circuit installation, manufactured (mobile) home, recreational vehicle or area which prohibits
grounding through the neutral conductor, the laundry center MUSTemploy a 4-condutor power supply cord NEMA 14- 30 type SRDTor ST (as required) rated at 240 volt AC minimum, 30 amp, with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for usewith clothes dryers. See ELECTRICAL CONNECTIONS. (Canada - 4-wire power supply cord is installed on laundry center).
OUTLET RECEPTACLE- NEMA 10-30R (3-wire) receptacle or NEMA 14- 30R (4-wire) receptacle to be located so the power supply cord isaccessiblewhen the laundry center isin an installed position.
I GASLaundry Center ]
CIRCUIT- Individual 15 amp minimum branch circuit fused with a time delay fuse or circuit breaker. POWER SUPPLY-3 wire, 120 volt single phase, 60 Hz, Alternating Current. POWER SUPPLY CORD -The gas laundry center is equipped with a 120 volt 3-wire power cord.
NOTE:Do not under
any circumstances
remove grounding prong from plug.
\
Grounding Prong
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within 42 inches (106.68 cm) of your laundry center's water inlet. The faucets
MUSTbe 3/4 inch (1.9 cm) garden hose type soinlet hoses can be connected. Water pressure MUST be between 10and 120 pounds per square inch (maximum unbalance pressure, hot vs. cold, 10 psi). Your water department can advise you of your
water )ressure.
DRAIN REQUIREMENTS
1. Drain capable of eliminating 17 gals. per minute.
2. A standpipe diameter of 11Ainches (3.18 cm) minimum.
3. The standpipe height above the floor should be: Minimum height: 33 inches (83.82 cm) Maximum height: 96 inches (244 cm)
t
NEMA 10-30R NEMA 14-30R
96"Max,
---T--'- (244 cm)
33" Min.
(83.82cm)
NOTE: For installations requiring a longer drain hose, have a qualified technician install a longer hose, PIN 134049201, available from an authorized parts distributor. Fordrain systems in the floor, install a siphon break kit, available from your local
hardware store.
EXHAUST SYSTEM REQUIREMENTS
Use only 4 inch (10.16 cm) diameter (minimum) flexible metal duct and approved vent hood which has a swing-out damper(s) that opens when the dryer is in operation. When the dryer stops, the damper(s) automatically closes to prevent drafts and the entrance of insects and rodents. To avoid restricting the outlet, maintain a minimum of 12 inches (38.5 cm) clearance between the vent hood and the ground or any other
obstruction.
The following are specific requirements for proper and safe operation of your laundry center. Failure to follow these instructions can create excessive drying times
and fire hazards.
Do not use plastic flexible duct or metal foil to exhaust the dryer. Excessivelint can build up inside the exhaust system and create a fire hazard and restrict air flow. Restricted air flow will increase drying times. If your present system is made up of plastic duct or metal foil duct, _lace it with a rigid or flexible metal duct. Ensure the present duct is free of any lint prior to installing laundry center dryer duct.
iii i i i
INCORRECT
Do not allow combustible materials (for
example: clothinq,draperies/curtains, paper) to come in contact with the exhaust system. The dryer MUSTNOT be exhausted into a chimney, a wall, a ceiling, or any concealed space of a building which can accumulate lint, resulting in a fire hazard.
Do not exceed the lenqth of duct pipe or
number of elbows allowed in the" EXHAUST DUCT LENGTHS" chart. Lint car/accumulate in the system, plugging the system
and creating a fire hazard, aswell as increasing drying times.
Do not screen the exhaust ends of the vent system, nor use any screws or rivets to assemble the exhaust svstem. Lint can become caught in the screen, on the screws or rivets, clogging the exhaust system and creating a fire hazard aswell asincreasing drying times. Usean approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fittings MUSTbe installed downstream
with the flow of air.
Explosion hazard. Do not install the laundry center where qasoline or other flammables are kept or stored.If
the laundry center isinstalled in a garage, it must be aminimum of 18 inches (45.7 cm) above the floor. Failure to do so can
result in death, explosion, fire or burns. The exhaust system back pressure MUST not exceed 0.6 inches(1.52 cm) of water column, measured with an inclined manometer at the point the exhaust connects to the dryer. The exhaust system should be inspected and cleaned a minimum of every two years with normal usage. The more the dryer is used, the more often you should check the exhaust system and vent hood for proper operation.
The maximum length of the exhaust system depends upon the type of duct used, number of elbows and type of exhaust hood.
If the dryer is not exhausted outdoors some fine lint will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard. The dryer exhaust system MUST be exhausted to
the outside of the dwelling!
The maximum length for both rigid and flexible duct is shown in the chart below.
EXHAUST DUCT LENGTHS
EXHAUST HOOD TYPE
Number
of 90°
Turns
\,
4"
10.2C 4)
MAXIMUM LENGTH OF 4-INCH (10.2 CM)
DIAMETER RIGID METAL DUCT
0
1
2 3
MAXIMUM LENGTH OF 4-INCH (10.2 CM)
0
1 2 3
56 ft. (17.07 m) 46 ft. (14.02 m) 34ft. (10.36 m) 32 ft. (9.75 m)
DIAMETER FLEXIBLE METAL DUCT
30ft. (9.14 m) 22 ft. (6.7 m)
16 ft. (4.88 m) 10 ft. (3.05 m)
Louvered
_25"
(6.
42 ft.
(12.8 m)
36 ft.
(10.97 m)
28 ft.
<8.53 m>
18 ft.
(5.48 m)
22 ft. (6.7 m)
14ft. (4.27 m) 10 ft. (3.05 m)
5ft. (1.5 m)
4
The laundry center may be exhausted four (4) ways with rear flush installation:
1. Straight back
2. Down (8 inch [20.32 cm] length of 4 inch [10.16 cm] rigid duct and 1 elbow down)
3. Left(8 inch [20.32 cm] length of 4 inch [10.16 cm] rigid duct, 1 elbow down and 1 elbow left)
4. Right (8 inch [20.32 cm] length of 4 inch [10.16 cm] rigid duct, 1 elbow down and 1 elbow right)
To exhaust up, add an 11 inch (27.94 cm) length of standard 4 inch (10.16 cm) diameter duct and a 90° elbow. The unit will
be positioned about 4Y2inches (11.43 cm) away from the wall (flush to wall exhausting may bedone by going below the dryer
then sideways). An exhaust hood positioned
to line up with the dryer exhaust can be installed
directly through the outside wall. To exhaust to the side
or down, add an 8 inch (20.32 cm) length of standard
4 inch (10.16 cm) diameter duct and a 90° elbow.
GAS SUPPLY REQUIREMENTS
1.Installation MUSTconform with local codes, or in the absence of local codes, with the National FuelGas Code, ANSI Z223.1
(latest edition) or in Canada, the current AN/CGA B149.
2.The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3.If codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing MUST be constructed of stainless steel or plastic-coated brass.
4.The gas supply line MUST have an individual shutoff valve.
5.A 1/8 inch (0.32 cm) N. RT.plugged tapping, accessible for test gage connection, MUST be installed immediately upstream of the gas supply connection to the dryer.
6.The dryer and its individual shutoff valve MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa).
7.The dryer MUSTbe isolated from the gassupply piping system by closing its individual manual shutoff valve during any pressuretesting of the gas supplypiping systemattest pressures equal to or less than 1/2 psig (3.45 kPa).
LOCATION OF YOUR LAUNDRY CENTER
DO NOT INSTALL YOUR LA UNDRY CENTER:
1.In an area exposed to dripping water or outside weather conditions.
2.In an area where it will come in contact with curtains or drapes.
3.On carpet. Floor MUSTbe solid with a maximum slope of 1 inch (2.54 cm).
INSTALLATION IN RECESSOR CLOSET
1.A laundry center installed in a bedroom, bathroom, recessor closet, MUSTbe exhausted outdoors.
2.No other fuel burning appliance shall be installed in the same closet asthe Gas laundry center.
3.Your laundry center needs the spacearound it for proper ventilation. DO NOT INSTALL YOUR LAUNDRY CENTER IN A CLOSET WITH A SOLID DOOR.
4.A mirfimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, isrequired. Air openings are required to be unobstructed when a door isinstalled. A Iouvered door with equivalent air openings for the full length of the door is acceptable.
5.The following illustrations show minimum clearance dimensions and air openings for proper operation in a recess or closet installation.
' 60 SQ. IN.
(387.1 SQ. CM)
0 IN.
(0 CM)_
DRYER
60 SQ. IN.
(387.1 SQ. CM)
T
Closet Door
60 SQ. IN.
(387.1 SQ. CM)
WAS.E.
60 SQ. IN.
(387.1 SQ. CM)
_U
m_
_S
L--J
m_
_u II
Zt_ m_
o