Crosley CED123SEW0, CED126SBW0, CED126SBW1, CED126SDW0, CED126SDW1 Installation Guide

...
ELECTRIC DRYER
INSTALLATI N INSTR
CTIONS
"WIDE
Para obtener acceso al manual de uso y cuidado en espa_ol, o para obtener informaci6n adicional acerca de su producto, visite:
Tenga listo su nOmero de modelo completo. Puede encontrar el nOmero de modelo y de serie dentro de la cavidad superior de la puerta.
MODELS - U.S.A. ONLY
www.whirlpool.com
DRYER SAFETY ......................................................................... 2
iNSTALLATiON REQUIREMENTS ............................................. 4
Tools and Parts ...................................................................... 4
Location Requirements ......................................................... 5
Electrical Requirements ........................................................ 6
Instafl Leveling Legs .............................................................. 7
Electrical Connection ............................................................ 7
VENTING ................................................................................... 13
Venting Requirements ......................................................... 13
Plan Vent System ................................................................. 14
Venting Kits .......................................................................... 14
Install Vent System .............................................................. 16
Connect Vent ........................................................................ 16
Level Dryer ........................................................................... 16
Complete installation Checklist ......................................... 16
Reverse Door Swing (Optional) .......................................... 17
Troubleshooting ................................................................... 19
W10514172A W10514174A=SP
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
WARNING - ...i.kofFi,o..
- Clothes dryer installation must be performed by a qualified installer.
- install the clothes dryer according to the manufacturer's instructions and local codes,
- Do not install a clothes dryer with flexible plastic venting materials or flexible metal (foil type) duct, if flexible metal duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers, Flexible venting
materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.
- To reduce the risk of severe injury or death, follow all installation instructions.
- Save these instructions.
State of California Proposition 65 Warnings: WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other reproductive harm.
2
IMPORTANT SAFETY INSTRUCTIONS
WARN ING." To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[] Read all instructions before using the dryer. [] Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry- cleaning solvents, or other flammable or explosive
substances as they give off vapors that could ignite or explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
[] Do not reach into the dryer if the drum is moving.
[] Do not install or store the dryer where it will be exposed
to the weather.
[] Do not tamper with controls.
[] Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
[] Clean lint screen before or after each load. [] Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See "Electrical Requirements" located in the installation
instructions for grounding instructions.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
When discarding or storing your old clothes dryer, remove the door.
SAVE THESE INSTRUCTIONS
iNSTALLATiON
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools needed:
REQUIREMENTS
Flat-blade screwdriver
Wire stripper
(direct wire installations)
1/4" nut driver (recommended)
Adjustable wrench that
opens to 1" (25 mm) or hex-head socket wrench
#2 Phillips screwdriver
Tin snips
(new vent installations)
db
Vent clamps
Utility knife
Level
Parts supplied (all models):
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts are included.
Parts needed: Check local codes. Check existing electrical supply and venting,
and read "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Mobile home installations require metal exhaust system hardware, available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the
"Assistance or Service" section of the "Use and Care Guide".
If using a power supply cord: Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain: [] A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
[] A UL listed strain relief.
Caulking gun and compound (for installing new exhaust vent)
Tape measure Pliers
4
Location Requirements
Explosion Hazard
Keep flarnnrnab(e materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (460 rnrn) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need:
[] A location allowing for proper exhaust installation.
See "Venting Requirements." [] A separate 30 amp circuit. [] If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements." [] A sturdy floor to support the total weight (dryer and load)
of 200 Ibs. (90.7 kg). The combined weight of a companion
appliance should also be considered. [] Level floor with maximum slope of 1" (25 mm) under entire
dryer. (If slope is greater than 1" [25 mm], install Extended
Dryer Feet Kit, Part Number 279810.) If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly. Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended. The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
installation clearances: The location must be large enough to allow the dryer door to
open fully. Dryer Dimensions
Minimum spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.
[] Additional spacing should be considered for ease of
installation and servicing.
[] Additional clearances might be required for wall, door, and
floor moldings.
[] Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
[] For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
[]
Companion appliance spacing should also be considered.
Minimum Required Spacing
_14"max,' -
_] 48in'_
h_I(_ mm 310crn)_.
-... .--__ (155cm)_
24in?*-
i-#0ram)
1"_ _ 29"_ _ 1" _h"*l< 27_"_151/2"I<-
(25ram)(737mm) (25mm)(25mm)(705mrn}(140mm)
A B
A. Recessed area B. Side view - closet or confined area
C. Closet door with vents
*Additional spacing recommended
Mobile home = Additional installation requirements This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
[]
Metal exhaust system hardware, which is available for purchase from your dealer.
[]
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
C
_f 3 I1.
_76mm)
433/8i ..............
*Most installations require a minimum 51/2'' (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting Requirements."
.... 223,,,,i' i
_ {1102ram}
.......29"
(737ram) (737rnm}
A B
A. Wideopening side-swing door B. Wideopening hamper door
Electrical Requirements
it is your responsibility:
[] To contact a qualified electrical installer. [] To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269. [] To supply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt
electrical supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit. [] Do not use an extension cord.
[] If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate. Electrical Connection
To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions
provided for it here.
[] If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see "Optional 3-wire
connection" section. [] This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground wire is
permanently connected to the neutral conductor (white wire)
within the dryer. If the dryer is installed with a 4-wire electrical
supply connection, the neutral ground wire must be removed
from the external ground connector screw (green screw), and
secured under the neutral terminal (center or white wire) of
the terminal block. When the neutral ground wire is secured
under the neutral terminal (center or white wire) of the terminal
block, the dryer cabinet is isolated from the neutral conductor. [] A 4-wire power supply connection must be used when the
dryer is installed in a location where grounding through the
neutral conductor is prohibited. Grounding through the neutral
is prohibited for (1) new branch-circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4) areas where local
codes prohibit grounding through the neutral conductors. if using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:
[] A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect to the
dryer must end in ring terminals or spade terminals with
upturned ends. [] A UL listed strain relief.
if your outlet looks like this:
Then choose a 4-wire power supply cord with
relief. The 4-wire power supply cord, at least
__ ring or spade terminals and UL listed strain
4-wire receptacle conductor) may be either green or bare. The (14-30R) neutral conductor must be identified by a white
if your outlet looks like this:
3-wire receptacle (10-30R)
if connecting by direct wire: Power supply cable must match power supply (4-wire or 3-wire)
and be: [] Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), covered with flexible metallic conduit. All
current-carrying wires must be insulated. [] 10-gauge solid copper wire (do not use aluminum). [] At least 5 ft. (1.52 m) long.
4 ft. (1.22 m) long, must have 4 10-gauge solid copper wires and match a 4-wire receptacle of NEMA Type 14-30 R. The ground wire (ground
cover.
Then choose a 3-wire power supply cord with
ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least
4 ft. (1.22 m) long, must have 3 10-gauge solid copper wires and match a 3-wire receptacle of
NEMA Type 10-30R.
GROUNDING iNSTRUCTiONS
=1For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer: This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
6
Loading...
+ 14 hidden pages