Cretors T-3000 Service Manual

T3000-M-A/E-S
3243 North California Avenue, Chicago, IL 60618
T-3000 POPCORN MACHINE SERVICE MANUAL
120 Volt, Single Phase, 60 Hz
230 Volt, Single Phase, 50 Hz
May 1999
READ and UNDERSTAND these servicing, and safety instructions before operating or servicing this popcorn machine
1
BEGIN SERIAL NO. 98074420
T3000-M-A/E-S
SAFETY FIRST
The information in this manual is essential for the safe installation and maintenance of your Cretors popcorn machine. The manual must be read and understood before installing, or maintaining this equipment, or equivalent training must be provided.
"The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury". Ref.: 29 CFR 1926.20 (b)(4)(a)(2)
It is understood that safety rules within individual companies vary. If a conflict exists between the safety procedures contained in this manual and the rules of a using compa ny, the more stringent rule should take precedence.
I INTRODUCTION
This manual is filled with time-saving and money-saving information regarding your Cretors popcorn machine. There is nothing, however, more important than the safety aids and warnings that are found throughout this document. The Safety Alert Symbol is used to identify topics of primary safety concern wherever they appear. Furthermore, a separate section has been included which deals exclusively with operation and accident prevention.
If, after reviewing this manual, anything is unclear or technical problems are encountered, contact the dealer from whom you purchased your machine for assistance and if there are any additional questions, feel free to contact our Customer Service Department at the address and/or phone number listed on the back cover of this manual. Always have the model and serial number of your machine available to assist in obtaining the correct information.
MODEL T-3000 T-3000 12 OZ. ELECTR IC COUNTER MODEL
Capacity: 12 oz. All-Steel Kettle, 280 one -ounce servings per hour Electrical: 1800 watts Dimensions: 21-1/2"D x 24-1/2"W x 34.5" H - - - - 54.6 cm D x 62.2 cm W x
87.6 cm H
May 1999
Net Weight: 85lbs. (35.6 kg.)
2
BEGIN SERIAL NO. 98074420
T3000-M-A/E-S
II SAFETY ALERT SYMBOL
The symbol shown below is used to call your attention to instructions concerning your personal safety and the safety of others. Watch this symbol. It points out important safety precautions. It means "ATTENTION! Become Alert! Your personal safety is involved!" Read the message that follows and be alert to the risk of personal injury or death.
III PURPOSE OF MANUAL
This instruction manual is intended to familiarize owners with the servicing and safety procedures associated with your Cretors popcorn machine.
This manual should be kept available to maintenance personnel.
A person who has not read and understood all service and safety instructions is not qualified to service the popcorn machine.
IV INSTALLATION INSTRUCTIONS
1. Location
Choose a location for your Cretors popcorn machine to maximize the ease of operation procedures. Check your local building and fire codes for location restrictions.
2. Power Supply
Check the nameplate to determine the required power supply.
If the supply cord is damaged, it must be replaced by Cretors’, or by a Cretors’ approved service agent, or a similarly qualified person in order to avoid a hazard.
Connect your popcorn popper only to the correct power source. Failure to do so may result in personal injury or death and may damage your machine.
May 1999
3
BEGIN SERIAL NO. 98074420
T3000-M-A/E-S
C. Cretors and Company recommends dedicated circuits for the T-3000 popcorn machine to avoid a voltage drop in the supply wire.
Make certain the Rocker Switches on the popcorn popper are in the 'OFF' position when plugging into power source. Failure to do so may result in damage to your machine or present a shock hazard.
3. Connecting Machine to Power Supply
A. Perform work only on de-energized circuits. Failure to do so may lead to
electrical shock resulting in personal injury or death.
B. Make certain that power supply circuit breakers are in the ‘OFF’ position.
C. Push the plug completely into the receptacle. If the cord has a twist lock plug be
sure to turn to lock in position. Turn ‘ON’ the power supply circuit breakers and then turn ‘ON’ the machine Rocker Switch.
May 1999
4
BEGIN SERIAL NO. 98074420
T3000-M-A/E-S
V SERVICE INSTRUCTIONS
In the case of improper service, qualified personnel only should perform the following diagnostic checks, and, if necessary, corresponding adjustments and repairs. Many of the following procedures present an electrical shock hazard and can cause serious injury or death.
1. Parts
When ordering parts, refer to the attached parts diagram. Always supply the serial number, model number, and voltage of your T-3000 popcorn machine.
If the supply cord is damaged, it must be replaced by Cretors’, or by a Cretors’ approved service agent, or a similarly qualified person in order to avoid a hazard.
THERMOSTAT OPERATION
A. The thermostat is installed as a safety device to prevent overheating of the kettle if
the machine should be left unattended momentarily while in operation. The operation of the thermostat is indicated by the kettle indicator light. The thermostat is located in the kettle. The indicator light should stay on for most of the popping cycle. The indicator light should go off 10-20 seconds before the corn finishes popping and the kettle is dumped. If the indicator light goes out 30 seconds or more before the corn finishes popping, the thermostat may be set too low and be in need of adjustment.
CAUTION! If the corn has dried out, it may not finish popping at normal temperature, and the light may appear to go out early. DO NOT ADJUST KETTLE TEMPERATURE BASED ON POOR QUALITY CORN.
CAUTION! Do not cover ventilation holes on top of machine.
B. If set too high (over 500°F 260
C. Repair part thermostats shipped from the factory have been factory adjusted to
switch off the current to the heatin g elements when the kettle temperature reaches 465° F (240oC). The factory setting should prove satisfactory; however, each
o
C), the thermostat can cause a serious fire hazard.
May 1999
5
BEGIN SERIAL NO. 98074420
+ 11 hidden pages