Crestron electronic WMKM-6X-DSW, MMK-6X-DSW, TPS-6X-DSW User Manual

Crestron MMK-6X-DSW & WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW Installation Guide
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW
Contents
Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW 1
Supplied Hardware......................................................................................................2
Installation...................................................................................................................4
Industry Compliance .................................................................................................12
Reference Documents................................................................................................12
Further Inquiries........................................................................................................12
Future Updates ..........................................................................................................12
Merchandise Returns / Repair Service ......................................................................13
CRESTRON Limited Warranty.................................................................................13
All brand names, product names and trademarks are the property of their respective owners.
©2009 Crestron Electronics, Inc.
Installation Guide – DOC. 6779A Contents i
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW
Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW

Description

Mud Mount Kits are the preferred mounting option for the TPS-6X-DSW when the cutout made in the drywall for docking station installation is too large. These kits provide support for additional plastering that can be applied to hide large irregularities in the cutout.
NOTE: If mounting into a material other than drywall (for example, wood lectern, concrete or rock) use the cutout template, available in the post-construction kit WMKM-6X-DSW. For concrete and rock mounting material, allow for proper ventilation before mounting the TPS-6X-DSW.
There are two Mud Mount Kits. The MMK-6X-DSW is a pre-construction accessory. Pre-construction refers to framed walls prior to hanging drywall. This accessory must be used with either the Pre-Construction Mount Kit (PMK-6X-DSW) or Back Box (BB-6X-DSW).
The WMKM-6X-DSW is a post-construction kit. Post-construction refers to framed walls with drywall hung. This accessory is designed with a mounting plate so that it can be placed anywhere on a wall without the support of a stud.
NOTE: Since the TPS-6X-DSW contains moving parts, mounting to a stud offers more support and is therefore highly recommended. Although Crestron® offers the post-construction WMKM-6X-DSW mounting option, a mounting option that is secured to a stud, such as the BB-6X-DSW or PMK-6X-DSW is highly recommended.
NOTE: If necessary, consult the latest revision of the TPS-6X-DSW Operations and Installation Guide (Doc. 6708) for a complete list of mounting options. The document is available from the Crestron website (
Installation Guide – DOC. 6779A Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW 1
http://www.crestron.com/manuals).
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW

Setup

Supplied Hardware

The MMK-6X-DSW consists of three parts. These parts produce an assembly that attaches to the BB-6X-DSW or PMK-6X-DSW. The WMKM-6X-DSW consists of six parts, three of which make up the MMK-6X-DSW, as well as a mounting plate, a set of mounting screws and a cutout template.
The mounting plate provides the necessary support for post-construction applications. An overlay cutout template (4506370) is supplied which is similar to a frame, the inner area of the frame is the shape of the required opening. Remove the center of the frame in order to use the template, refer to the illustration on page 4.
Supplied Hardware for the MMK-6X-DSW and WMKM-6X-DSW
DESCRIPTION PART NUMBER QUANTITY
Metal, Plate, Mud Ring 2022809 1 Metal Plate, Adjustment 2017631 2 Hardware, Metal, Push-On 2004121 4 Metal, Plate, Mounting
(WMKM-6X-DSW only) Screw, #06-32 x 1 1/2”, Pan, Phil
(WMKM-6X-DSW only) Overlay, Template, Wall Cutout
(WMKM-6X-DSW only)
2022811 1
2007254 4
4506370 1
The dimensions of the MMK-6X-DSW and WMKM-6X-DSW are shown below and on the next page.
Dimensional Drawing – Mud Ring Plate
10 . 46 i n
7.57 in
(19 .22 c m)
6.03 i n
(15 .31 c m)
(26 .57 c m)
8.92 in
(22.66 cm)
0.05 i n
(0 .13 cm)
0.50 i n
(1 .27 cm)
1.03 i n
(2 .63 cm)
4.00 in
(10 .16 c m)
2.26 in
(5.73 cm)
2 Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW Installation Guide – DOC. 6779A
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW
Dimensional Drawing – Adjustment Plate
0.38 in
( 0.95 c m)
10 .24 in
( 26.01 c m)
0.38 i n
(0 .95 cm)
Dimensional Drawing – Mounting Plate
10 .31 in
(26 .19 cm )
8.00 in
(20.32 cm)
0.06 in
(0.15 cm)
8.82 in
(22.39 cm)
(16. 13 cm)
6.35 in
Installation Guide – DOC. 6779A Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW 3
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW
Drywall Cutout Template and Dimensions (supplied with WMKM-6X-DSW only)
9 1/16 in
(230 mm )
7 11/16 in
(196 mm )
6 1/8 i n
(156 mm )
6 9/16 in
(167 mm )

Installation

This section provides an installation procedure for each Mud Mount Kit. The “MMK-6X-DSW Procedure” starts below and the “WMKM-6X-DSW Procedure” starts on page 7. Be sure to review each procedure before starting.
MMK-6X-DSW Procedure
This section provides the necessary steps for the assembly of the MMK-6X-DSW with either the BB-6X-DSW or PKM-6X-DSW. It is assumed that the BB-6X-DSW or PKM-6X-DSW has been secured to the stud according to the instructions in the latest revisions of their Installation Guides (Doc. 6728 and Doc. 6778 respectively). It is also assumed that drywall is in place and a cutout for the TPS-6X-DSW is made in the drywall.
Complete the steps in the order provided. The only tools or materials required and not supplied are four standard drywall screws, #2 Phillips screwdriver, a level and tools/material to apply drywall joint compound.
CAUTION: Allow an air gap of at least 12 inches (30.48 cm) in the wall cavity above and below the TPS-6X-DSW for heat dissipation.
4 Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW Installation Guide – DOC. 6779A
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW
NOTE: The illustrations in this procedure show the installation of the MMK-6X-DSW with the PMK-6X-DSW. Even though the illustrations only show the PMK-6X-DSW, they are identical for the BB-6X-DSW.
1. Pass an adjustment plate through the opening and align its two center holes with the top two pins on the PMK-6X-DSW. Verify that the pins on the adjustment plate are not between (facing) the adjustment plate and the PMK-6X-DSW. Refer to the illustration below for visual guidance.
Secure Adjustment Plates to PMK-6X-DSW (or BB-6X-DSW)
ADJU STMENT PLATE (2 ) (2017631)
PMK-6X-DSW
NOTE: BACK VIEW OF INSTALLA TI ON.
PUSH-ON FASTENER (4) (2004121 )
2. Slide a push-on fastener over each pin of the PMK-6X-DSW (or BB-6X-DSW) to loosely secure the adjustment plate and the mounting plate. Do not push the push-on fasteners all the way down onto the pins. Slide them on enough to keep the adjustment plate and mounting plate as one adjustment/mounting plate assembly.
3. Use the second adjustment plate and repeat steps 1 and 2 using the lower two PMK-6X-DSW (or BB-6X-DSW) pins.
NOTE: When installing into the PMK-6X-DSW, verify that the 18 AWG bus wire securing the cables for the TPS-6X-DSW remains attached.
4. Insert the symmetrical mud ring plate into the opening, as shown in the illustration on the following page.
Installation Guide – DOC. 6779A Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW 5
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW
Insert and Secure Mud Ring Plate into PMK-6X-DSW (or BB-6X-DSW)
DRYWALL
PMK-6X-DSW
DRYWALL SCREWS (NOT INCLUDED) SCREW LENGTH SHOULD NOT EXCEED DRYW ALL THICKNESS BY MORE THAN 1/2" (13 MM).
MUD RING PLATE (2022809 )
5. When the mud ring plate is in position, bend the top two flanges of the plate upward and the bottom two flanges downward.
If mounting into the PMK-6X-DSW, bend the flanges approximately
90 degrees.
If mounting into the BB-6X-DSW, bend the flanges back as far as they
can go.
6. Use four standard drywall screws (length should not excee d dry w al l thickness by more than 1/2 inch) to secure the mud ring plate to the rest of the assembly. The screws pass through the clearance holes in the PMK-6X-DSW (or BB-6X-DSW) and are secure d i n the extruded holes of the adjustment plates.
7. Verify that the mud ring plate is level.
NOTE: Do not overtighten screws. Doing so may over-dimple or rip the mud ring plate.
8. Use a #2 Phillips screwdriver and tighten the drywall screws by hand so that they slightly dimple into the holes in the mud ring plate.
6 Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW Installation Guide – DOC. 6779A
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW
9. Apply drywall joint compound as needed to finish the cutout. Avoid covering the four tapped mounting holes.
10. Run the necessary cables for the TPS-6X-DSW and secure them behind the drywall.
11. When dry, the wall mount docking station can be installed using the four tapped holes in the PMK-6X-DSW. Refer to the latest revision of the TPS-6X-DSW Operations and Installation Guide (Doc. 6708) for installation instructions. Refer also to the comprehensive illustration below.
TPS-6X-DSW Mounting Using MMK-6X-DSW – Exploded View
PMK-6X-DSW
DRYWALL
MUD RING PLATE (2022809 )
DRYWALL SCREWS (NOT INCLUDED) SCREW LENGTH SHOULD NOT EXCEED DRYWALL THICKNESS BY
MORE THAN 1/2" (13 MM).
NOTE: REQUIRED ADJUSTMENT PLATES AND
PUSH-ON FASTENERS NOT SHOWN.
SC REW (4) #06-32 1 1/2 " PA N HEAD (2007254 )
TPS-6X-DSW
WMKM-6X-DSW Procedure
This section provides the necessary steps for the assembly and installation of the WMKM-6X-DSW into a wall. Review the procedure and complete the steps in the order provided. The only tools or materials required and not supplied are a drywall saw or equivalent, a level, four standard drywall screws, #2 Phillips screwdriver and tools/material to apply drywall joint compound.
Installation Guide – DOC. 6779A Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW 7
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW
CAUTION: Allow an air gap of at least 12 inches (30.48 cm) in the wall cavity above and below the TPS-6X-DSW for heat dissipation.
1. Insert the two pins on one adjustment plate into the top two outer holes
on the mounting plate, as shown in the illustration below.
Create the Adjustment/Mounting Plate Assembly
PUSH ON FASTENER (4) (2004121)
MOUNTING PLATE (2022811)
ADJU STMENT PLATE (2) (2017631 )
2. Slide a push-on fastener over each pin on the adjustment plate to
loosely secure the adjustment plate and the mounting plate. Do not push the push-on fasteners all the way down onto the pins. Slide them on enough to keep the adjustment plate and mounting plate as one adjustment/mounting plate assembly .
3. Use the second adjustment plate and repeat steps 1 and 2 using the
lower two holes on the mounting plate.
4. Locate an area on the wall that is free of miscellaneous wiring and
studs.
5. Make a small hole near the middle of the designated site; verify that the
location is suitable.
8 Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW Installation Guide – DOC. 6779A
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW
NOTE: Make the cutout as level as possible. The mounting plate allows for only minor leveling adjustments.
6. Use the drywall saw or equivalent and the included drywall cutout
template to produce an accurate and level cutout in the drywall.
7. Insert the symmetrical mud ring plate into the opening, as shown in the
illustration below.
Insert Mud Ring Plate into Opening
DRYWALL
DRYWALL SCREWS (NOT INCLUDED) SCREW LENGTH SHOULD NOT EXCEED DRYW ALL THICKNESS BY MORE THAN 1/2" (13 MM).
MUD RING PLATE (2022809 )
8. Carefully pass the adjustment/mounting plate assembly through the
opening and rest the assembly against the interior surface of the drywall. Verify that the adjustment plates are between the mounting plate and the drywall.
9. When the adjustment/mounting plate assembly is in position, bend the
top two flanges of the mud ring upward (approximately 90 degrees) and the bottom two flanges downward (approximately 90 degrees). Refer to the illustration on the following page.
NOTE: Adjustment/mounting plate assembly will have a slight play; this is normal. It allows for minor adjustments to the entire assembly during installation.
Installation Guide – DOC. 6779A Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW 9
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW
Bend Flanges – 1 of 4 Flanges Bent
BACK OF DRYWALL
10. Use four standard drywall screws (length should not exceed drywall
thickness by more than 1/2 inch) to secure the mud ring plate to the adjustment/mounting plate assembly . The screws are secured in the extruded holes of the adjustment plate and pass through the clearance holes in the mounting plate.
11. Verify that the plate is lev el before tightening.
NOTE: Do not over tighten screws. Doing so may damage the plate.
12. Use a #2 Phillips screwdriver and tighten the drywall screws by hand
so that they slightly dimple into the holes in the mud ring plate.
13. Run the necessary cables for the TPS-6X-DSW and secure them behind
the drywall.
14. Apply drywall joint compound as needed to finish the cutout. Avoid
covering the four tapped mounting holes.
15. When the joint compound is dry, the wall mount docking station can be
installed using the four tapped holes in the mounting plate. Refer to the latest revision of the TPS-6X-DSW Operations and Installation Guide (Doc. 6708) for details. Refer also to the comprehensive illustration on the following page.
10 Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW Installation Guide – DOC. 6779A
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW
TPS-6X-DSW Mounting Using WMKM-6X-DSW – Exploded View
PUSH-ON FASTENER S (4) (2004121 )
MOUNTING PLATE (20022811 )
ADJUSTMENT PLATE (2) (2017631 )
DRYWALL
MUD RING (2022809 )
TPS-6X-DSW
DRYWALL SCREWS (NOT INCLUDED) SCREW LENGTH SHOULD NOT EXCEED DRYW ALL THICKNESS BY MOR E THA N 1 / 2" (13 MM ).
SC REW #06-32 1 1/2" PA N HEAD (2007254 )
Installation Guide – DOC. 6779A Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW 11
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW

Resources

Industry Compliance

As of the date of manufacture, the MMK-6X-DSW and WMKM-6X-DSW have been tested and found to comply with specifications for CE marking.

Reference Documents

The latest version of all documents mentioned within the guide can be obtained from the Crestron website ( product manuals arranged in alphabetical order by model number.
List of Related Reference Documents
www.crestron.com/manuals). This link will provide a list of
DOCUMENT TITLE
BB-6X-DSW Pre-Construction Wall Mount Back Box for TPS-6X-DSW PMK-6X-DSW Pre-Construction Wall Mount Kit for TPS-6X-DSW TPS-6X-DSW Wall Mount Docking Assembly for TPS-6X

Further Inquiries

If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling Crestron at 1-888-CRESTRON [1-888-273-7876].
You can also log onto the online help section of the Crestron website
www.crestron.com/onlinehelp) to ask questions about Crestron products. First-time
( users will need to establish a user account to fully benefit from all available features.

Future Updates

As Crestron improves functions, adds new features and extends the capabilities of the MMK-6X-DSW and WMKM-6X-DSW, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision.
Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download column.
12 Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW Installation Guide – DOC. 6779A
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW

Return and Warranty Policies

Merchandise Returns / Repair Service
1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address.
2. Products may be returned for credit, exchange or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA.
3. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in mat erial s and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered.
This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regard ing the nature and extent of the dealer's warranty, if any.
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced or removed.
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party.
CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty.
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties.
Trademark Information
All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered trademark of Microsoft Corporation. Windows95/98/Me/XP/Vista and WindowsNT/2000 are trademarks of Microsoft Corporation.
Installation Guide – DOC. 6779A Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW 13
Crestron Electronics, Inc. Installation Guide – DOC. 6779A
15 Volvo Drive Rockleigh, NJ 07647 (2023087) Tel: 888.CRESTRON 01.09 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.
Loading...