CRESTRON GREEN LIGHT™ Architectural Dimming

Introduction

CRESTRON GREEN LIGHT architectural dimming cabinets come pre-configured with GLX architectural dimming and switching modules already installed. In addition, branch circuit breakers come preinstalled and prewired to the modules. The cabinets only require installation and wiring of feed and load circuits.

Industry Compliance

The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
The following diagram shows CRESTRON GREEN LIGHT architectural dimming cabinets in a lighting application that is controlled by an IPAC system.
CRESTRON GREEN LIGHT Architectural Dimming Cabinets in a Typical Lighting Application
(E227280 (cabinet) and E103692 (modules))
Crestron Electronics, Inc. Installation Guide – DOC. 6688A
15 Volvo Drive Rockleigh, NJ 07647 (2020963) Tel: 888.CRESTRON 02.09 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.
Architectural Dimming CRESTRON GREEN LIGHT™

Physical Description

This section shows the exterior and interior dimensions of the CRESTRON GREEN LIGHT Architectural Dimming cabinet.
External Dimensions of CRESTRON GREEN LIGHT Architectural Dimming Cabinets
W1 W3
W2
Ø HOLES
1
21
(547 mm)
1
21
(547 mm)
7
16
"
2
"
2
" (11 mm) MOUNTING
H2
1
21
"
2
(547 mm)
1
"
21
2
(547 mm)
5
10
(270 mm)
3
10
(259 mm)
"
8
"
16
10
(256 mm)
CONCENTRIC TECHNICAL KNOCKOUTS,
3
31 TOTAL (FOR
TYPICAL TOP AND BOTTOM
1
"
16
" (19 mm) &
4
1
" (13 mm) CONDUIT)
2
1
6
16
(154 mm)
H1
KNOCKOUTS, 4 TOTAL,
3
" (19 mm)CONDUIT) TYPICAL BOTH SIDES
(FOR
4
"
DIMENSION GLE-*-2X2 GLE-*-3X2 GLE-*-2X4 GLE-*-3X4
Module Spaces
W1 W2 W3
H1 H2
22 7/8” (582 mm) 22 7/8” (582 mm) 35 1/16” (891 mm) 35 1/16” (891 mm) 21 5/8” (550 mm) 21 5/8” (550 mm) 33 3/4” (858 mm) 33 3/4” (858 mm)
20 1/16” (510 mm) 20 1/16” (510 mm) 32 3/16” (818 mm) 32 3/16” (818 mm)
67 13/16 (1723 mm) 96” (2439 mm) 67 7/8” (1725 mm) 89 13/16 (2282 mm)
4 6 8 12
1 7/16” (37 mm) 5” (27 mm) 1 7/16” (37 mm) 1 15/16” (50 mm)
2 CRESTRON GREEN LIGHT Architectural Dimming Installation Guide – DOC. 6688A
CRESTRON GREEN LIGHT™ Architectural Dimming
Interior Dimensions of CRESTRON GREEN LIGHT Architectural Dimming Cabinets (GLE-XXX-Xx2, left; GLE-XXX-Xx4, right)
W1
W2
H1
W3W3
GROUND LUG
GROUND BARS
W1
W2
H1
W4
GROUND LUG
W5
GROUND BARS
W3W3W3W3
SERVICE
SCREWDRIVER
SERVICE SCREWDRIVER
Interior Dimensions of CRESTRON GREEN LIGHT Architectural Dimming Cabinets
GLE-120 GLE-277
DIMENSION 2X2 3X2 2X4 3X4 2X2 3X2 2X4 3X4
H1
W1
W2
W3
W4
W5
14 7/8”
(378 mm)
8 3/16”
(208 mm)
6 5/16”
(161 mm)
1 7/8”
(48 mm)
18 1/4”
(464 mm)
8 3/16”
(208 mm)
6 5/16”
(161 mm)
1 7/8”
(48 mm)
14 7/8”
(378 mm)
6 13/16”
(174 mm)
4 15/16”
(126 mm)
1 7/8”
(48 mm)
- - 21 5/8” (550 mm)
- - 19 3/4” (502 mm)
14 7/8”
(378 mm)
6 13/16”
(174 mm)
4 15/16”
(126 mm)
1 7/8”
(48 mm)
21 5/8”
(550 mm
19 3/4”
(502 mm)
11 11/16” (297 mm)
8”
(204 mm)
3 7/8”
(99 mm)
2”
(51 mm)
15 1/16
(383 mm)
8”
(204 mm)
3 7/8”
(99 mm)
2”
(51 mm)
11 11/16” (297 mm)
6 11/16”
(170 mm)
2 9/16”
(66 mm)
2”
(51 mm)
- - 21 1/2” (547 mm)
- - 17 3/8” (442 mm)
11 11/16” (297 mm)
6 11/16”
(170 mm)
2 9/16”
(66 mm)
2”
(51 mm)
21 1/2”
(547 mm)
17 3/8”
(442 mm)
Installation Guide – DOC. 6688A CRESTRON GREEN LIGHT Architectural Dimming 3
Architectural Dimming CRESTRON GREEN LIGHT™

Installation

Observe the following when installing the cabinet:
The cabinet must be mounted by a licensed electrician in accordance with all national and local codes.
Refer to the diagram below for specific requirements.
Allow adequate clearance in front of the cover for servicing.
The cabinet is designed for surface mounting on a wall.
Cabinets are intended for indoor use only.
The ambient temperature range should be 32°F to 104°F (0°C to 40°C). The relative humidity should range
from 10% to 90% (non-condensing).
Mounting Location
WALL
3'
(0.9 m)
MINIMUM REQUIRED
CLEARANCE
6'-7"
(2.01 m)
MAXIMUM HEIGHT OF
HIGHEST BREAKER
(FROM GROUND)
4 CRESTRON GREEN LIGHT Architectural Dimming Installation Guide – DOC. 6688A
CRESTRON GREEN LIGHT™ Architectural Dimming
Y

Wiring

NOTE: All wiring must be installed in accordance with all local and national electrical codes. NOTE: Refer to the torque settings specified on pages 6, 7 and 8.
CRESTRON GREEN LIGHT cabinets are shipped with GLX modules installed and prewired to the branch circuit breakers. The following must be performed after installation:
Connect incoming feed conductors to the breaker panel (section A of the following diagram)
Connect load wiring to GLX module outputs (section B of the following diagram)
Connect control wiring (section C of the followi ng diagram)
FEED:
3-PHASE 4-WIRE MAIN LUG ONLY
TO LOADS:
2W + GND 16A (MAX)
A
B
C
CLASS 2
WIRING ONLY
CLASS 2 WIRING ONL
Installation Guide – DOC. 6688A CRESTRON GREEN LIGHT Architectural Dimming 5