Digital Telephone Hybrid
INSTALLATION and QUICK START GUIDE
Fill in for your records:
Serial Number:
Purchase Date:
Rio Rancho, NM, USA www.lectrosonics.com
LECTROSONICS, INC.2
Installation Guide
Important Safety Instructions
This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure -- voltage that may be sufficient to constitute a risk of shock.
This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. Please read the manual.
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electri­cian for replacement of the obsolete outlet.
10) Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11) Only use attachments/accessories specified by the manufacturer.
12) Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13) Unplug this apparatus during lightning storms or when unused for long periods of time.
14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15) WARNING -- TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
Rio Rancho, NM 3
Table of Contents
Important Safety Instructions .................................................................................................................................................................. 3
Table of Contents ...................................................................................................................................................................................... 4
Introduction ................................................................................................................................................................................................ 5
Unpacking the unit ................................................................................................................................................................................... 5
Controls and Features .............................................................................................................................................................................. 6
Front Panel ............................................................................................................................................................................................... 6
POWER On/Off Switch ........................................................................................................................................................................ 6
USB Port .............................................................................................................................................................................................. 6
Status LED ........................................................................................................................................................................................... 6
Rear Panel ............................................................................................................................................................................................... 6
POWER Plug........................................................................................................................................................................................ 6
RS232 Port ........................................................................................................................................................................................... 6
USB Port .............................................................................................................................................................................................. 6
Programmable Input and Output Ports ................................................................................................................................................ 6
Mode Switch ......................................................................................................................................................................................... 5
DANI ..................................................................................................................................................................................................... 5
TEL/CODEC RC .................................................................................................................................................................................. 5
Audio Inputs and Outputs .................................................................................................................................................................... 5
Telephone Set/Line .............................................................................................................................................................................. 5
Hardware Installation ................................................................................................................................................................................ 7
Installing the DM system into a rack........................................................................................................................................................ 7
Cables ...................................................................................................................................................................................................... 7
Audio Connections................................................................................................................................................................................... 7
Audio Inputs (AUX and CODEC) ............................................................................................................................................................. 7
Unbalanced Sources ............................................................................................................................................................................ 7
Balanced Sources ................................................................................................................................................................................ 7
Audio Outputs (AUX and CODEC) .......................................................................................................................................................... 8
Telephone Line Jack ................................................................................................................................................................................ 8
Programmable Inputs .............................................................................................................................................................................. 8
Programmable Outputs ............................................................................................................................................................................ 8
Expansion I/O ports ................................................................................................................................................................................. 9
CODEC and TEL Remote Control Ports ................................................................................................................................................. 9
Installing LecNet2™ Software and USB Driver ................................................................................................................................... 10
Installing LecNet2™ Software ............................................................................................................................................................... 10
Installing the LecNet2™ USB Driver ..................................................................................................................................................... 10
USB driver installation Windows XP...................................................................................................................................................... 10
First Time Installation ......................................................................................................................................................................... 10
Installation of Additional Units (or LecNet 2™ devices) .................................................................................................................... 11
USB Driver Installation (Windows 2000) ............................................................................................................................................... 12
First Time Installation ......................................................................................................................................................................... 12
Basic System Setup ................................................................................................................................................................................ 13
Control System Interconnections .......................................................................................................................................................... 13
Initial Setup ............................................................................................................................................................................................ 13
Master/Slave Configuration ................................................................................................................................................................... 14
Using the DMTH4 Control Panel to Change Master/Slave Mode ......................................................................................................... 14
Initial Setup Hints ................................................................................................................................................................................... 15
Example Teleconferencing Setup .......................................................................................................................................................... 16
Setting up the DMTH4 Main Matrix ....................................................................................................................................................... 17
Setting up the DM1624 Main Matrix ...................................................................................................................................................... 17
Setting up the DM1624 Expansion Matrix ............................................................................................................................................. 17
Setting up the DMTH4
Output Source Multiplexer ................................................................................................................................................................. 18
Basic System Operation ......................................................................................................................................................................... 19
Making a Phone Call ............................................................................................................................................................................... 19
Make a Telephone Call Using a Telephone Set ..................................................................................................................................... 19
Make a Telephone Call Using the Activity Tab ...................................................................................................................................... 19
Using the Touch Tone Pad ..................................................................................................................................................................... 19
Use the “Type the number to dial” box................................................................................................................................................... 20
Use the Phone Book .............................................................................................................................................................................. 20
Setting Up Automatic Telephone Answer and Automatic Disconnect ................................................................................................... 20
Connecting to the CODEC Interface using the Activity Tab .................................................................................................................. 21
FCC Part 68 Compliance ....................................................................................................................................................................... 22
FCC Part 15 Compliance ....................................................................................................................................................................... 22
Warranty .................................................................................................................................................................................. Back Cover
LECTROSONICS, INC.4
Introduction
The purpose of this guide is to assist in the setup and
operation of a typical DMTH4 system. This guide
assumes familiarity with the DM Series Digital Audio
Processors, its components and software menus and
setup screens. To get the most out of the DMTH4
system, it is suggested to review the information
presented in the DMTH4 Series Reference Manual.
A detailed Help is also available to assist in the setup
and operation of a DMTH4 system using the USB
interface and a Windows® 2000 or Windows® XP
computer system. In addition to assistance setting up
and operating the DMTH4 system, the Help files include
a complete listing of the DMTH4 Serial Commands.
These commands can be used to setup and operate
the DMTH4 system via external devices using either the
USB or RS232 serial port.
Unpacking the unit
Compare the packing list enclosed with the unit with the
original order. Inspect all items for damage. Immedi-
ately call 1-800-821-1121 to report any items that are
missing or damaged. The sooner we get notified, the
sooner we can get any needed replacement items
shipped to your location.
Installation Guide
Rio Rancho, NM 5
Controls and Features
Front Panel
R
TELEPHONE HYBRID INTERFACE
POWER On/Off Switch
The Power On/Off Switch is used to turn the DMTH4 on (1) or off (0).
USB Port
Standard USB connector for the setup and control of a DMTH4 from an Windows 2000 or Windows XP com­puter system with USB interface.
Status LED
The DMTH4 is normally configured as the end slave unit in a DM Series stack. In this configuration, the Status LED glows steadily when power is applied and a Master unit has been detected. The STATUS indicator will blink to indicate that it has not found the Master unit or some other error exists.
POWERUSBSTATUSMODE
POWER On/Off SwitchUSB PortStatus LEDMode Switch
Note: The DMTH4 is shipped from the factory configured as a Master unit. In this mode, the Status indicator glows steadily when power is applied.
Mode Switch
If a unit configured to run in Slave mode doesn’t detect a master unit on powerup, it will refuse to boot up and the Status LED will blink rapidly. In this case, pressing the Mode switch will force the unit to boot up tempo­rarily in Master mode to allow settings to be examined or changed. Cycling the power returns the DMTH4 to Slave mode.
Pressing the Mode switch while powering up the DMTH4, places the unit in Software Update mode. The Status LED blinks slowly while the firmware is updated, then extinguishes when the process is complete. Cycling power exits Software Update mode.
Rear Panel
16: IN 4
11: OUT 5 12: OUT 7 13: GND 14: +5V 15: IN 2
17: IN 6 18: IN 8 19: IN 10 20: +5V
21: OUT 2 22: OUT 4 23: OUT 6 24: OUT 8 25: +5V
DANI
LecNet 2
1: GND
13
7: IN 11
2: IN 1
25
8: GND
3: IN 3
9: OUT 1
4: IN 5
10: OUT 3
5: IN 7
PROGRAMMABLE
USB
INPUTS / OUTPUTS
POWER
90-240V 50/60Hz 15W
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1
14
RS-232
6: IN 9
POWER Plug RS232 USB Programmable
Input and Output
Ports
POWER Plug
Standard NEMA 5-15 three-pin power plug capable of accepting 100-240 VAC, 47-63 Hz.
RS232 Port
A serial RS232 interface provided for setup and control via computer serial port, or for connecting RS-232 serial control devices from other companies.
USB Port
Standard USB connector for the setup and control of a DMTH4 from an Windows 2000 or WIndows XP com­puter system with USB interface.
Programmable Input and Output Ports
Programmable inputs or outputs used to enable control over a variety of parameters or to indicate the current state of a programmable input.
AB
TX RX
RX
TX
EXPANSION TEL RC
Codec RC
CODEC RC
Tel RC
MIC/LINE
OUTPUTS
INPUTS
CODEC AUX
CODEC AUX
Line Inputs
TELEPHONE
LINE
SET LINE
Mic/Line Oututs
(Codec/Aux)
Complies with Part 68 FCC rules. Registration Number:4J3BR09BDMTH4
0 . 9 B
Ringer Equivalence:
LECTROSONICS, INC.
U.S. Patent Number: 5,414,776
TELEPHONE HYBRID
MADE IN U.S.A.
Telephone
Set/Line
(Codec/Aux)
DANI
DANI, or Digital Audio Network Interface, is used to route the digital audio signals passing between the master and slave units in stacked configurations.
TEL/CODEC RC
These interfaces are used to connect RCWTH4 remote control units.
Audio Inputs and Outputs
Analog audio input and output connectors for Codec and Aux ports .
Telephone Set/Line
RJ11 jacks for connecting a standard telephone line and a single-line telephone set to the DMTH4.
LECTROSONICS, INC.6
DM In
+
-
Source
+
Unbalanced source to DM input
(3-Wire)
Shield
DM In
+
-
Source
+
Unbalanced source to DM input
(2-Wire)
Shield
Balanced source to DM input
(3-Wire)
DM In
+
-
Source
+
-
Shield
Hardware Installation
Installation Guide
Installing the DM system into a rack
The DMTH4 occupies a single space. There are no
special ventilation requirements. Mount with 4 rack
screws using the appropriate mounting holes. It is
recommended to use nylon washers to prevent damage
to the front panel’s finish when tightening the screws.
For North American installations, connect the Power
Cable supplied with the unit between the DMTH4 and a
stable power source. All DM processors have internal
switching power supplies that can tolerate voltages
ranging from 100 VAC to 240 VAC. Use an approved
power cable for installations outside North America.
Cables
It is recommented to use lacing bars for cable strain
relief when mounting in a rack. Use only professional
audio cable with proper shielding - typically, two con-
ductor plus ground/shield.
Audio Connections
The analog audio inputs and outputs are connected
through 5 pin de-pluggable connectors. Strip the
insulation back 1/8 to 3/16" but do not tin (apply solder
to) the leads. Insert the wire into a de-pluggable
connector, leaving less than 1 mm of bare wire ex-
posed, then tighten the retaining screw.
Audio Inputs (AUX and CODEC)
Unbalanced Sources
Unbalanced audio sources (positive and ground) include items such as consumer VCR’s, DVD players, etc., and may use both two wire and three wire cables. In either case, the positive output from the source should be connected to the appropriate positive (+) input on the DMTH4. The shield or negative (–) output should be connected the DM’s negative (–) input. Two wire cables should have a jumper between the DMTH4 negative input and ground. Three wire cables should have the shield connected to the DMTH4’s ground input and the shield and negative (–) leads joined together at the unbalanced source end.
Caution: Do not over tighten the retaining screw.
Retaining Screw
(Do not overtighten)
5-pin depluggable
connector
Do not leave more than 1
mm of exposed wire
beyond the connector.
Do not apply
solder to leads
Note the labeling on the DMTH4 Chassis for the
positive and negative leads. Ground is shared between
two connections (the center pin).
Note: The DM Series does not have a “pin 1 problem.” Inputs and outputs are true differential connections.
Balanced Sources
Balanced differential sources from external equipment and microphones should be wired according to Bal- anced source to DM input (3-Wire). (See illustration.) When connecting balanced sources to the DMTH4, it is important to not connect chassis ground (shield) to either signal conductor.
Rio Rancho, NM 7
Audio Outputs (AUX and CODEC)
The AUX and Codec outputs are a balanced differential configuration and include an attenuator to reduce the signal to mic level. Wire these outputs as indicated in the following illustration.
DM Out
DM Out
+
-
DM Out to Balanced Input
Shield
(3-Wire)
+
-
DM Out to Unbalanced Input
Shield
(3-Wire)
Destination
+
-
Destination
+
Potentiometer Connection for
Analog Control of Gain
10K Linear Potentiometer
CCW
CW
+5V To Programmable Input Pin
Gnd
Contact Closure as Programmable Input
To Programmable Input Pin
Gnd
DC Voltage Source as Programmable Input
To Programmable Input Pin
0VDC (Off) to +5VDC (On)
Gnd
Output RP Gain Control
Inputs control tab in the Control Panel GUI. See the Rear Panel Ctrl tab in the Control Panel software Help
for setting all programmable input parameters.
on the Programmable
DM Out
+
-
Shield
Destination
+
DM Out to Unbalanced Input
(2-Wire)
Telephone Line Jack
Connect a standard telephone cable with RJ11 connec­tors between the back panel Telephone Line Jack and the host telephone system.
Programmable Inputs
Programmable inputs are provided to enable external control over a variety of parameters. Each input can respond to a contact closure, a DC voltage source, or the variable voltage output from a potentiometer. The following illustrates common connections to the pro­grammable input pins. (See also Programmable Inputs and Outputs Wiring Example.)
No external pull-up resistors are necessary because each programmable input is internally pulled up through a 100K resistor to +5V. When using a continuous voltage with one of the programmable inputs, the function of the programmable input must be set to either
Analog Input RP Gain Control
or
Analog
Programmable Outputs
Programmable outputs are used to indicate the current state of a programmable input, monitor activity on telephone or codec interfaces, and monitor active preset changes. Each programmable output is the electrical equivalent of a contact closure to ground. When a programmable output is “active”, it conducts current to ground. When the programmable output is “inactive”, no current flows to ground. The maximum usable voltage for the programmable outputs is 40 V and they will safely conduct up to 100 mA DC continu­ous. Following are some typical uses for the program­mable outputs.
LED is on when the programmable output is active
+5VDC (from Programmable I/O Pins 14, 20, 25)
Programmable Output Pin
LED is off when the programmable output is active
+5VDC (from Programmable I/O Pins 14, 20, 25)
Programmable Output Pin
Gnd (from Programmable I/O Pins 1, 8, 13)
Relay is on when the programmable output is active
Coil current <100mA
Programmable Output Pin
Gnd (from Programmable I/O Pins 1, 8, 13)
Relay Coil
380 Ohms
380 Ohms
1N4001 or equiv.
LECTROSONICS, INC.8
External DC Voltage Source (<40VDC)
Installation Guide
PROGRAMMABLE INPUTS/ OUTPUTS
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
6 - IN 20 7 - IN 22 8 - GND 9 - OUT 9 10 - OUT 11
11- OUT 13 12 - OUT 15 13 - GND 14 - +5V 15 - IN 13
16 - IN 15 17 - IN 17 18 - IN 19 19 - IN 21 20 - +5V
21 - OUT 10 22 - OUT 12 23 - OUT 14 24 - OUT 16 25 - +5V
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
TX
RX
RX
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
6 - IN 9 7 - IN 11 8 - GND 9 - OUT 1 10 - OUT 3
11- OUT 5 12 - OUT 7 13 - GND 14 - +5V 15 - IN 2
16 - IN 4 17 - IN 6 18 - IN 8 19 - IN 10 20 - +5V
21 - OUT 2 22 - OUT 4 23 - OUT 6 24 - OUT 8 25 - +5V
EXPANSION
19
PROGRAMMABLE INPUTS/ OUTPUTS
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
6 - IN 20 7 - IN 22 8 - GND 9 - OUT 9 10 - OUT 11
11- OUT 13 12 - OUT 15 13 - GND 14 - +5V 15 - IN 13
16 - IN 15 17 - IN 17 18 - IN 19 19 - IN 21 20 - +5V
21 - OUT 10 22 - OUT 12 23 - OUT 14 24 - OUT 16 25 - +5V
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
TX
RX
RX
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
6 - IN 9 7 - IN 11 8 - GND 9 - OUT 1 10 - OUT 3
11- OUT 5 12 - OUT 7 13 - GND 14 - +5V 15 - IN 2
16 - IN 4 17 - IN 6 18 - IN 8 19 - IN 10 20 - +5V
21 - OUT 2 22 - OUT 4 23 - OUT 6 24 - OUT 8 25 - +5V
EXPANSION
19
PROGRAMMABLE INPUTS/ OUTPUTS
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
6 - IN 20 7 - IN 22 8 - GND 9 - OUT 9 10 - OUT 11
11- OUT 13 12 - OUT 15 13 - GND 14 - +5V 15 - IN 13
16 - IN 15 17 - IN 17 18 - IN 19 19 - IN 21 20 - +5V
21 - OUT 10 22 - OUT 12 23 - OUT 14 24 - OUT 16 25 - +5V
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
TX
RX
RX
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
6 - IN 9 7 - IN 11 8 - GND 9 - OUT 1 10 - OUT 3
11- OUT 5 12 - OUT 7 13 - GND 14 - +5V 15 - IN 2
16 - IN 4 17 - IN 6 18 - IN 8 19 - IN 10 20 - +5V
21 - OUT 2 22 - OUT 4 23 - OUT 6 24 - OUT 8 25 - +5V
EXPANSION
19
PROGRAMMABLE INPUTS/ OUTPUTS
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
6 - IN 20 7 - IN 22 8 - GND 9 - OUT 9 10 - OUT 11
11- OUT 13 12 - OUT 15 13 - GND 14 - +5V 15 - IN 13
16 - IN 15 17 - IN 17 18 - IN 19 19 - IN 21 20 - +5V
21 - OUT 10 22 - OUT 12 23 - OUT 14 24 - OUT 16 25 - +5V
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
TX
RX
RX
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
6 - IN 9 7 - IN 11 8 - GND 9 - OUT 1 10 - OUT 3
11- OUT 5 12 - OUT 7 13 - GND 14 - +5V 15 - IN 2
16 - IN 4 17 - IN 6 18 - IN 8 19 - IN 10 20 - +5V
21 - OUT 2 22 - OUT 4 23 - OUT 6 24 - OUT 8 25 - +5V
EXPANSION
19
PROGRAMMABLE INPUTS/ OUTPUTS
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
6 - IN 20 7 - IN 22 8 - GND 9 - OUT 9 10 - OUT 11
11- OUT 13 12 - OUT 15 13 - GND 14 - +5V 15 - IN 13
16 - IN 15 17 - IN 17 18 - IN 19 19 - IN 21 20 - +5V
21 - OUT 10 22 - OUT 12 23 - OUT 14 24 - OUT 16 25 - +5V
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
TX
RX
RX
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
6 - IN 9 7 - IN 11 8 - GND 9 - OUT 1 10 - OUT 3
11- OUT 5 12 - OUT 7 13 - GND 14 - +5V 15 - IN 2
16 - IN 4 17 - IN 6 18 - IN 8 19 - IN 10 20 - +5V
21 - OUT 2 22 - OUT 4 23 - OUT 6 24 - OUT 8 25 - +5V
EXPANSION
19
PROGRAMMABLE INPUTS/ OUTPUTS
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
6 - IN 20 7 - IN 22 8 - GND 9 - OUT 9 10 - OUT 11
11- OUT 13 12 - OUT 15 13 - GND 14 - +5V 15 - IN 13
16 - IN 15 17 - IN 17 18 - IN 19 19 - IN 21 20 - +5V
21 - OUT 10 22 - OUT 12 23 - OUT 14 24 - OUT 16 25 - +5V
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
TX
RX
RX
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
6 - IN 9 7 - IN 11 8 - GND 9 - OUT 1 10 - OUT 3
11- OUT 5 12 - OUT 7 13 - GND 14 - +5V 15 - IN 2
16 - IN 4 17 - IN 6 18 - IN 8 19 - IN 10 20 - +5V
21 - OUT 2 22 - OUT 4 23 - OUT 6 24 - OUT 8 25 - +5V
EXPANSION
19
PROGRAMMABLE INPUTS/ OUTPUTS
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
6 - IN 20 7 - IN 22 8 - GND 9 - OUT 9 10 - OUT 11
11- OUT 13 12 - OUT 15 13 - GND 14 - +5V 15 - IN 13
16 - IN 15 17 - IN 17 18 - IN 19 19 - IN 21 20 - +5V
21 - OUT 10 22 - OUT 12 23 - OUT 14 24 - OUT 16 25 - +5V
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
TX
RX
RX
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
6 - IN 9 7 - IN 11 8 - GND 9 - OUT 1 10 - OUT 3
11- OUT 5 12 - OUT 7 13 - GND 14 - +5V 15 - IN 2
16 - IN 4 17 - IN 6 18 - IN 8 19 - IN 10 20 - +5V
21 - OUT 2 22 - OUT 4 23 - OUT 6 24 - OUT 8 25 - +5V
EXPANSION
19
PROGRAMMABLE INPUTS/ OUTPUTS
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
6 - IN 20 7 - IN 22 8 - GND 9 - OUT 9 10 - OUT 11
11- OUT 13 12 - OUT 15 13 - GND 14 - +5V 15 - IN 13
16 - IN 15 17 - IN 17 18 - IN 19 19 - IN 21 20 - +5V
21 - OUT 10 22 - OUT 12 23 - OUT 14 24 - OUT 16 25 - +5V
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
TX
RX
RX
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
6 - IN 9 7 - IN 11 8 - GND 9 - OUT 1 10 - OUT 3
11- OUT 5 12 - OUT 7 13 - GND 14 - +5V 15 - IN 2
16 - IN 4 17 - IN 6 18 - IN 8 19 - IN 10 20 - +5V
21 - OUT 2 22 - OUT 4 23 - OUT 6 24 - OUT 8 25 - +5V
EXPANSION
19
Note: The diagram shows an external DC source powering the relay coil. This is necessary whenever coil voltages exceed 5 V.
Both LEDs and 5V relay coils can be powered by the +5
V DC pins on the programmable input connector, as
long as the maximum combined current for all LEDS
and relay coils does not exceed 100 mA.
Programmable Inputs and
Outputs Wiring Example
IN 1
IN 2
IN 3
Potentiometer
Potentiometer
OFF
ON
PROGRAMMABLE INPUTS/OUTPUTS
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
1
ccw cw
ccw cw
Switch
11- OUT 5 12 - OUT 7 13 - GND 14 - +5V 15 - IN 2
16 - IN 4 17 - IN 6 18 - IN 8 19 - IN 10 20 - +5V
21 - OUT 2 22 - OUT 4 23 - OUT 6 24 - OUT 8 25 +5V
6 - IN 9 7 - IN 11 8 - GND 9 - OUT 1 10 - OUT 3
13
500 Ohms
500 Ohms
500 Ohms
Three Programmable Inputs:
2 - 10 K linear potentiometers for volume control 1 - Tobble switch for muting
3 Programmable Outputs:
LEDS for function indicators (380 to 500 Ohm resistors in-line to avoid burning out LEDS)
Common Connections can be used for
all voltage and ground connections
NOTE
among all devices.
LED
OUT 3
LED
OUT 4
LED
OUT 1
CODEC and TEL Remote Control Ports
1 GND
2 Connect Button
3 Privacy Button
4 Volume Up Button
5 Volume Down Button
6 Privacy LED
7 Connect LED
8 GND
WARNING: NOT
based device interconnects. Connecting them to Ethernet, CobraNet or other network based device may cause damage to either unit.
In a stacked configuration, one unit must be configured as the Master unit and the others as Slave units. The DMTH4 is normally configured as the last Slave unit in a DM Series chain.
To connect the Master/Slave units, plug one end of a 12 inch Cat5e cable (two are supplied with each with unit) to the transmit (TX) port on the Master unit, and con­nect the other end to the corresponding receiver (RX) port on the Slave unit immediately below the Master. Repeat this procedure with the second Cat5e cable.
CAUTION: Do not connect these ports to each other on a single unit, and to not cross the cables between the units.
1 - GND
6 - IN 20
11- OUT 13
2 - IN 12
7 - IN 22
12 - OUT 15
3 - IN 14
8 - GND
13 - GND
4 - IN 16
9 - OUT 9
14 - +5V
5 - IN 18
10 - OUT 11
15 - IN 13
PROGRAMMABLE
INPUTS/ OUTPUTS
1 - GND
6 - IN 9
11- OUT 5
2 - IN 1
7 - IN 11
12 - OUT 7
3 - IN 3
8 - GND
13 - GND
4 - IN 5
9 - OUT 1
14 - +5V
5 - IN 7
10 - OUT 3
15 - IN 2
MasterSlaveMasterSlave
1 - GND
11- OUT 13
6 - IN 20
2 - IN 12
12 - OUT 15
7 - IN 22
3 - IN 14
13 - GND
8 - GND
4 - IN 16
14 - +5V
9 - OUT 9
5 - IN 18
15 - IN 13
10 - OUT 11
PROGRAMMABLE INPUTS/ OUTPUTS
1 - GND
11- OUT 5
6 - IN 9
2 - IN 1
12 - OUT 7
7 - IN 11
3 - IN 3
13 - GND
8 - GND
4 - IN 5
14 - +5V
9 - OUT 1
5 - IN 7
15 - IN 2
10 - OUT 3
The Expansion I/O connectors are
Ethernet, CobraNet or any other network
1 - GND
6 - IN 20
11- OUT 13
16 - IN 15
16 - IN 15
21 - OUT 10
17 - IN 17
22 - OUT 12
18 - IN 19
23 - OUT 14
19 - IN 21
24 - OUT 16
20 - +5V
25 - +5V
A B
TX
EXPANSION
16 - IN 4
21 - OUT 2
17 - IN 6
22 - OUT 4
18 - IN 8
23 - OUT 6
19 - IN 10
24 - OUT 8
20 - +5V
25 - +5V
21 - OUT 10
16 - IN 15
22 - OUT 12
17 - IN 17
23 - OUT 14
18 - IN 19
24 - OUT 16
19 - IN 21
25 - +5V
20 - +5V
A B
TX
EXPANSION
21 - OUT 2
16 - IN 4
22 - OUT 4
17 - IN 6
23 - OUT 6
18 - IN 8
24 - OUT 8
19 - IN 10
25 - +5V
20 - +5V
LINE OUT
15151616131314141717181819
- + - +
RX
TXTXRX
- + - +
- + - +
RX
TXTXRX
- + - +
- + - +
- + - +
LINE OUT
3 41 2 5 6 7
- + - +
- + - +
LINE OUT
15151616131314141717181819
- + - +
- + - +
LINE OUT
3 41 2 5 6 7
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
7 - IN 22
12 - OUT 15
8 - GND
13 - GND
9 - OUT 9
14 - +5V
10 - OUT 11
15 - IN 13
PROGRAMMABLE INPUTS/ OUTPUTS
6 - IN 9
11- OUT 5
7 - IN 11
12 - OUT 7
8 - GND
13 - GND
9 - OUT 1
14 - +5V
10 - OUT 3
15 - IN 2
11- OUT 13
6 - IN 20
12 - OUT 15
7 - IN 22
13 - GND
8 - GND
14 - +5V
9 - OUT 9
15 - IN 13
10 - OUT 11
PROGRAMMABLE INPUTS/ OUTPUTS
11- OUT 5
6 - IN 9
12 - OUT 7
7 - IN 11
13 - GND
8 - GND
14 - +5V
9 - OUT 1
15 - IN 2
10 - OUT 3
21 - OUT 10
17 - IN 17
22 - OUT 12
18 - IN 19
23 - OUT 14
19 - IN 21
24 - OUT 16
20 - +5V
25 - +5V
16 - IN 4
21 - OUT 2
17 - IN 6
22 - OUT 4
18 - IN 8
23 - OUT 6
19 - IN 10
24 - OUT 8
20 - +5V
25 - +5V
21 - OUT 10
16 - IN 15
22 - OUT 12
17 - IN 17
23 - OUT 14
18 - IN 19
24 - OUT 16
19 - IN 21
25 - +5V
20 - +5V
21 - OUT 2
16 - IN 4
22 - OUT 4
17 - IN 6
23 - OUT 6
18 - IN 8
24 - OUT 8
19 - IN 10
25 - +5V
20 - +5V
A B
TX
EXPANSION
A B
TX
EXPANSION
15151616131314141717181819
- + - +
- + - +
RX
TXTXRX
3 41 2 5 6 7
- + - +
- + - +
15151616131314141717181819
- + - +
- + - +
RX
TXTXRX
3 41 2 5 6 7
- + - +
- + - +
LINE OUT
- + - +
LINE OUT
- + - +
LINE OUT
- + - +
LINE OUT
- + - +
- + - +
- + - +
- + - +
- + - +
1 - GND
6 - IN 20
11- OUT 13
16 - IN 15
21 - OUT 10
2 - IN 12
7 - IN 22
12 - OUT 15
17 - IN 17
22 - OUT 12
3 - IN 14
8 - GND
13 - GND
18 - IN 19
23 - OUT 14
4 - IN 16
9 - OUT 9
14 - +5V
19 - IN 21
24 - OUT 16
5 - IN 18
10 - OUT 11
15 - IN 13
20 - +5V
25 - +5V
A B
TX
Expansion I/O ports
The four RJ45 connectors on the rear panel are used to
interconnect LecNet2™ units together. These ports are
only used to transfer digital audio information via the
Digital Audio Network Interface (DANI) between the
units.
Expansion I/O Ports (DANI Bus)
Rio Rancho, NM 9
CODEC and TEL Remote Control Ports
PROGRAMMABLE
INPUTS/ OUTPUTS
6 - IN 9
11- OUT 5
7 - IN 11
12 - OUT 7
8 - GND
13 - GND
9 - OUT 1
14 - +5V
10 - OUT 3
15 - IN 2
11- OUT 13
6 - IN 20
12 - OUT 15
7 - IN 22
13 - GND
8 - GND
14 - +5V
9 - OUT 9
15 - IN 13
10 - OUT 11
PROGRAMMABLE INPUTS/ OUTPUTS
11- OUT 5
6 - IN 9
12 - OUT 7
7 - IN 11
13 - GND
8 - GND
14 - +5V
9 - OUT 1
15 - IN 2
10 - OUT 3
EXPANSION
16 - IN 4
21 - OUT 2
17 - IN 6
22 - OUT 4
18 - IN 8
23 - OUT 6
19 - IN 10
24 - OUT 8
20 - +5V
25 - +5V
21 - OUT 10
16 - IN 15
22 - OUT 12
17 - IN 17
23 - OUT 14
18 - IN 19
24 - OUT 16
19 - IN 21
25 - +5V
20 - +5V
A B
TX
EXPANSION
21 - OUT 2
16 - IN 4
22 - OUT 4
17 - IN 6
23 - OUT 6
18 - IN 8
24 - OUT 8
19 - IN 10
25 - +5V
20 - +5V
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
Expansion Port Digital Audio Network Interface Interconnection Diagram
LINE OUT
15151616131314141717181819
- + - +
RX
TXTXRX
- + - +
- + - +
RX
TXTXRX
- + - +
- + - +
- + - +
LINE OUT
3 41 2 5 6 7
- + - +
- + - +
LINE OUT
15151616131314141717181819
- + - +
- + - +
LINE OUT
3 41 2 5 6 7
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
1 - GND 2 - IN 12 3 - IN 14 4 - IN 16 5 - IN 18
1 - GND 2 - IN 1 3 - IN 3 4 - IN 5 5 - IN 7
6 - IN 20
11- OUT 13
7 - IN 22
12 - OUT 15
8 - GND
13 - GND
9 - OUT 9
14 - +5V
10 - OUT 11
15 - IN 13
PROGRAMMABLE INPUTS/ OUTPUTS
6 - IN 9
11- OUT 5
7 - IN 11
12 - OUT 7
8 - GND
13 - GND
9 - OUT 1
14 - +5V
10 - OUT 3
15 - IN 2
11- OUT 13
6 - IN 20
12 - OUT 15
7 - IN 22
13 - GND
8 - GND
14 - +5V
9 - OUT 9
15 - IN 13
10 - OUT 11
PROGRAMMABLE INPUTS/ OUTPUTS
11- OUT 5
6 - IN 9
12 - OUT 7
7 - IN 11
13 - GND
8 - GND
14 - +5V
9 - OUT 1
15 - IN 2
10 - OUT 3
16 - IN 15
21 - OUT 10
17 - IN 17
22 - OUT 12
18 - IN 19
23 - OUT 14
19 - IN 21
24 - OUT 16
20 - +5V
25 - +5V
A B
- + - +
TX
RX
TXTXRX
EXPANSION
16 - IN 4
21 - OUT 2
17 - IN 6
22 - OUT 4
18 - IN 8
23 - OUT 6
19 - IN 10
24 - OUT 8
20 - +5V
25 - +5V
- + - +
21 - OUT 10
16 - IN 15
22 - OUT 12
17 - IN 17
23 - OUT 14
18 - IN 19
24 - OUT 16
19 - IN 21
25 - +5V
20 - +5V
A B
- + - +
TX
RX
TXTXRX
EXPANSION
21 - OUT 2
16 - IN 4
22 - OUT 4
17 - IN 6
23 - OUT 6
18 - IN 8
24 - OUT 8
19 - IN 10
25 - +5V
20 - +5V
- + - +
LINE OUT
15151616131314141717181819
- + - +
- + - +
LINE OUT
3 41 2 5 6 7
- + - +
- + - +
LINE OUT
15151616131314141717181819
- + - +
- + - +
LINE OUT
3 41 2 5 6 7
- + - +
- + - +
- + - +
- + - +
- + - +
- + - +
Installing LecNet2™ Software and USB Driver
LecNet2™ is a Graphic User Interface (GUI) designed to allow easy setup and monitoring of DM components using Windows LecNet2™ includes the necessary Control Panels to configure and monitor all the DM series products plus the Venue Modular Receiver system.
®
2000 or XP computer systems.
Installing LecNet2™ Software
1. Use the computer system’s control panel to remove any previously installed versions of LecNet2™ software. (This will ensure you are using the latest release.)
2. Insert the LecNet2™ program disk supplied with your system into the computer system’s CD-ROM drive.
3. The CD should automatically start the installation procedure. If it doesn't, click "Start" on the WIndows Task Bar then click "Run..." Enter the Drive number followed by "Setup.exe" then click OK.
USB driver installation Windows XP
First Time Installation
When a LecNet2™ device is connected to the PC for the very first time, the Windows Found New Hardware Wizard automatically opens. Use the following proce­dure to install the LecNet2™ USB driver using the Wizard.
1. Place the LecNet2™ Installation Disk in the PC’s CD-ROM drive.
2. On the first page of the Wizard, select the option Install from a list or specific location (Ad­vanced) and click Next> to continue.
4. Follow the on-screen instructions to install the
LecNet2 software.
Installing the LecNet2™ USB Driver
There are two methods of connecting a Windows®­based computer system to the DM component, either via a USB cable or an RS-232 cable. Although the USB port offers significantly increased speed and conve­nience over standard RS-232 links, it does require the installation of a LecNet2™ USB driver.
The LecNet2 USB driver is not part of the standard Windows® 2000 and XP driver libraries. As a result, connecting a computer system to a DM system for the first time is different than subsequent installations. There are a few minor differences between installing the LecNet2 USB drivers on a Windows 2000 versus a Windows XP system.
3. Select "Search for the best driver in these locations", then check "Search removable media (floppy, CD-ROM...)" and click Next> to continue.
4. Windows searchs the CD for the driver and when it
has found it, it is likely that a dialog will open warning you that the driver has not passed Win­dows Logo Testing, click Continue Anyway.
LECTROSONICS, INC.10
5. When the driver installation is complete, the final page of the Wizard appears. Click Finish to complete the LecNet2™ USB driver installation.
Installation Guide
2. Windows discovers the previously installed USB driver. It is likely that a dialog will open warning you that the driver has not passed Windows Logo Testing. Click Continue Anyway.
Installation of Additional Units (or LecNet 2™ devices)
The Windows XP operating system regards all Lecnet2™ devices as separate USB devices because each has a unique serial number. Because of this, Windows XP will want to install the USB driver every time it encounters a LecNet2™ device whose serial number it does not recognize. However, if the Lec­Net2™ USB driver has already been installed at least once before on the computer system, the process is simplified because the LecNet2™ installation disk is not required.
Use the following procedure if the LecNet2™ USB driver was previously installed on the computer system.
1. On the first page of the Wizard, select Install the software automatically (Recommended) and click Next> to continue.
Rio Rancho, NM 11
3. When the driver installation is complete, the final page of the Wizard appears. Click Finish. It is now possible to connect to the LecNet2™ device.
USB Driver Installation (Windows 2000)
First Time Installation
When a LecNet2™ device is connected to a comptuer system running the Windows for the very first time, the Windows Found New Hard- ware Wizard automatically opens. (Dm1624 shown for illustrative purposes only.)
Use the following procedure to install the LecNet2™ USB driver using the Wizard.
1. Connect a cable between the DM processor USB port and the computer system. Place the LecNet2™ Installation Disk in the computer system’s CD-ROM drive and click Next> to con- tinue.
®
2000 operating system
3. Check "CD-ROM drives" then click Next> to search the LecNet2™ CD for the USB driver.
4. When it is found, the LecNet2™ device name will be displayed. Click Next> to install the driver.
2. Select "Search for a suitable driver for my device (recommended)" and click Next> to
continue.
5. When the driver installation is complete, the final page of the Wizard appears. Click Finish. It is now possible to connect to the LecNet2™ device.
LECTROSONICS, INC.12
Basic System Setup
Control System Interconnections
In addition to a Windows® 2000 or XP based computer system, DMTH4s can be controlled by external serial control system using the RS-232 interface, such as those from Crestron® and AMX®.
Two RS-232 cables are provided. They are identified by the color of the cable. The black cable is used to connect a computer system to the DMTH4 and the red cable is used to connect a serial control system such as those from Crestron® or AMX®.
Installation Guide
RS-232Port
Warning: Do not use the black cable for Crestron for use with a WIndows® 2000 or XP computer system .
Note: Crestron® is a trademark of Crestron Electronics, Inc. AMX® is a registered tradename of AMX Coporation.
USB Port
®
or AMX® connections. It is strictly
Initial Setup
The initial setup of a DMTH4 system is a relatively simple three step process: connect the unit to the computer, turn on the computer and start the appropri­ate control panel, preset the input, matrix and output source. This process assumes that LecNet2™ and, if necessary, the USB driver have been previously installed. If they have not been installed, please refer to
Installing LecNet2™ Software and USB Driver.
1) Connect the computer system to the DMTH4 unit
using either the BLACK DB9 to stereo mini (TRS 1/8”) cable for RS-232 communications or the USB cable for USB control. (Both cables are included with the unit.)
the list for the DMTH4 unit being set up.
4) If the “Just a Reminder” dialog appears, click OK to continue.
5) Click Connection on the Main Menu bar, then select the type of connection between the computer system or external control system and the DMTH4 unit. The choices are:
USB - used when the computer is connected to the DMTH4 unit via the front or rear panel USB port.
Note: Only one DMTH4 unit at a time can be connected to the computer system using a single RS-232 cable. Multiple units may be connected using multiple RS-232 cables, each attached to a separate COM port on the computer system. Multiple units may be connected using multiple USB cables and multiple USB ports on the computer system, or a USB hub attached to the computer system.
2) Turn the computer system on. After the boot
Connecting to DMTH4 through USB
sequence is complete, turn on the DMTH4. When the DMTH4 STATUS LED glows steadily, click Start, then All Programs on the computer system
3) Select LecNet2, then select the control panel from
Rio Rancho, NM 13
Network - One or more DMTH4 devices may be made
available for network connections by connecting them to a gateway computer system. A gateway PC, or gateway server acts as a middleman, receiving commands for a DMTH4 over a network connection, and forwarding them to the DMTH4, which is connected to it via USB. To work as a gateway server the PC must be a member of some local area network (LAN) or the internet, by means of an Ethernet connection, and be running the Lecnet2 “Net Server” program.
Extron IPL T S - One or more DMTH4 devices may be
made available for network connections by connect­ing them to an Extron IPL T S ethernet control interface. The IPL T S interface acts as a middle­man, receiving commands for a DMTH4 over a network connection, and forwarding them to the DMTH4, which is connected to it via an RS232 port. To work as a gateway server the IPL T S interface must be a member of some local area network (LAN) or the Internet, by means of an Ethernet connection.
Serial->COM1 - An serial port for RS-232 communica-
tions between the DMTH4 and the computer.
Note: The control panel will list any COM ports available on the computer system.
Serial->COM2 - Same as above.
Go Offline - No Connection Made, this mode can be
used to configure the DMTH4 off line and is the default mode.
The DMTH4 can be configured on site or a configura­tion file can be created in advance, then downloaded into the unit in the installation. The minimum required setup to pass audio includes: Inputs, Matrix and Out Source. Input and output filters and compressors are used to tailor the system for specific audio situations.
The DMTH4 leaves the factory configured as a Master unit to facilitate initial setup. If the unit has been configured as a slave, it can be temporarily set to Master mode via the front panel MODE button. If the front panel MODE button is used, the unit will return to Slave Mode the next time the DMTH4 power is cycled.
LECTROSONICS, INC.
RIO RANCHO, NM U.S.A.
TELEPHONE HYBRID INTERFACE
MODE Button
USBSTATUSMODE
POWER
Using the DMTH4 Control Panel to Change Master/Slave Mode
Changing the Master/Slave Mode can be easily accom­plished through the DMTH4 Control Panel.
To do this, select Connect on the DMTH4 Control Panel Menu Bar, then click “Connect >USB” to open the “Select Lecnet2 Device” dialogue. Highlight the DMTH4 and click “OK.”
Master/Slave Configuration
When stacking multiple DM Series units, one unit is always set as the Master and all subsequent units are set as Slaves. The DMTH4 is normally configured as a Slave unit and placed at the end of the DM Series chain.
Inputs Matrix Out Source
Connecting to DMTH4 through USB
LECTROSONICS, INC.14
Installation Guide
WIth the DMTH4 connection configured, it is now possible to set the Master/Slave operating mode. This is done by selecting “Device Setup” from the Control Panel Menu Bar. Select “Expansion Mode” from the drop down menu and select “Slave.”
Setting Master/Slave Mode
Initial Setup Hints
1) Right clicking the mouse is powerful in this inter­face. You can activate quick access to a number of setup functions (for example - right click in any input box in the INPUTS tab). It also allows some powerful cut and paste capabilities - especially in the matrix setup and the filter (both input and output).
2) Store startup settings in a startup default preset. (See Storing and Recalling Presets in the online HELP.)
3) Presets will take about 4 seconds to switch due to the many parameters in the unit - audio will switch off temporarily during a preset switch to avoid feedback. If you need quicker response with no interruption to the audio, use macros instead - try using the macro recorder for making any changes. The only changes that cannot be made in a macro are filter adjustments.
4) Store presets after changes are made and not before they are made.
5) Help is always available by clicking Help on the Main Menu Bar. This Help is a comprehensive resource and includes the latest revisions to the software and firmware.
IMPORTANT: Any changes made during setup must be saved in the unit via the preset menu.
For direct support from the factory, call (800) 821-1121
Ask for anyone in the SALES department. They will be able to answer your setup and/or technical questions or will get the correct person who can help on the phone.
Rio Rancho, NM 15
Example Teleconferencing Setup
Link Conference Rooms with a DMTH4 Example Setup
The following information describes setting up a DMTH4 to connect two locations for a conference. The DMTH4 is designed to be part of a DM Series chain. In this example, the DMTH4 is a slave unit to a DM1624 Series Automixer. This example also as­sumes that the hardware has been installed and is operating properly. Conceptually, the setup has two conference rooms, each with two microphones and two ceiling mounted speakers connected to a DM1624 in a Mix-Minus configuration with a DMTH4 linking the
In 1 In 2 In 3
In 16
Out 1
Out 2
DM Series Automixer (DM1624 Shown)
X
X
Spkr 1 Spkr 2
Main Matrix
rooms together via a telephone connection. (See
Conference Rooms with a DMTH4, Example Setup
The actual process to create the signal path so all members of both conference rooms have the ability to hear and be heard all other members in the conference rooms requires four simple steps: setting up the DMTH4 Main Matrix, setting up the DM1624 Main Matrix, setting up the DM1624 Expansion Matrix and setting up the DMTH4 Output Source Multiplexer. This is illustrated in
gram
.
DANI Bus
Conference Room Signal Flow Dia-
Exp. Matrix
X X
Link
.)
Mix Bus 1
(1) TEL IN
(2) CODEC IN
(3) AUX IN
X
Conference Room Signal Flow Diagram
Mix Bus 2
Mix Bus 3
Mix Bus 4
Mix Bus 5
Mix Bus 24
DMTH4
X
Main Matrix
Expansion Mix Bus 1
Expansion Mix Bus 2
Out Source
Multiplexer
(1) TEL OUT
(2) CODEC OUT
(3) AUX OUT
LECTROSONICS, INC.16
Installation Guide
The following are assumed:
A POTS line has already been connected to the DMTH4 rear panel Telephone Line jack
The DMTH4 has been connected to the DM1624 via the DANI bus
The microphones and overhead speakers are already connected to the DM1624 in a Mix-Minus configuration.
The result will be that when a person talks into Mic 1 in Conference Room 1, they will be heard both in Confer­ence Room 1 and in Conference Room 2. Likewise, if a person in Conference Room 2 talks into one of the microphones in that room, they will be heard both Conference Room 2 and Conference Room 1.
The following discusses setting up a DM Series consist­ing of a DM1624 Digital Automixer and a DMTH4 Digital Telephone Hybrid on near end of the telephone connec­tion. The same process is used to set up the DM Series at the other far end of the telephone connection.
Setting up the DMTH4 Main Matrix
The TEL Input needs to be configured so that it is connected to DANI Bus Mix Busses 1 and 2. (See Conference Room Signal Flow Diagram.)
1.) Select the Matrix Tab in the DMTH4 Control Panel, then select the “Main Matrix” sub tab. Right click the TEL input to Mix Bus 1 crosspoint and select “Enable Crosspoint” from the popup menu
2.) Repeat Step 1 for Mix Bus 2.
Matrix Tab
Click on Crosspoint Button
the speakers in Conference Room 1. (See Conference Room Signal Flow Diagram.)
1.) Select the Matrix Tab on the DM1624 Control Panel, then select the “Inputs to Outputs” sub tab.
2.) Right click the Input Channel 1 to Output Channel 2 crosspoint and select “Enable Crosspoint” from the popup menu.
Matrix Tab
Inputs to
Outputs Tab
Input Channel 2 to
Output Channel 1
Input Channel 1 to
Output Channel 2
3.) Right click the Input Channel 2 to Output Channel 1 crosspoint and select “Enable Crosspoint” from the list.
Setting up DMTH4 Main Matrix
Setting up the DM1624 Main Matrix
The DM1624 Main Matrix needs to be configured so the microphone inputs are connected to the output chan­nels used to drive the local sound reinforcement speakers. These inputs will be mixed together with the audio received from the DMTH4 TEL Input. Both local audio and audio from Conference Room 2 are heard on
Setting up the DM1624 Expansion Matrix
Once the DM1624 Main Matrix has been set up, the DM1624 Expansion Bus Matrix needs to be configured so the local audio is sent back to the DMTH4 for distribution to the remote Conference Room (Confer­ence Room 2 in this example). (See Link Conference Rooms with a DMTH4, Example Setup and Conference Room Signal Flow Diagram.)
1.) Select the Inputs to Expansion Outputs Tab in the DM1624 Matrix Tab.
2.) Right click the Input Channel 1 to Expansion Out Channel 1 crosspoint and select “Enable Crosspoint” from the popup menu.
3.) Right click the Input Channel 2 to Expansion Out Channel 1 crosspoint and select “Enable Crosspoint” from the popup menu.
Rio Rancho, NM 17
Inputs to
Expansion
Outputs Tab
Connect Input Channels 1 and 2 to Expansion Out
Channel 1
Setting up the DMTH4 Output Source Multiplexer
The TEL output needs to be configured so that Expan­sion Final Mix 1 is sent over the telephone line for use at the remote Conference Room.
1.) Select the Out Source Tab in the DMTH4 Control Panel.
2.) Click the down arrow on the TEL Output Source selection list and select Exp Final Mix 1 from the list.
Out Source Tab
TEL Output Source
LECTROSONICS, INC.18
Basic System Operation
Installation Guide
The following procedures are designed to aquaint the user of the basic steps required to set up a DMTH4 and provide a foundation for developing more complex operations.
It is assumed that the LecNet2™ software and drivers have been previously installed, a Windows-based computer system is connected to the USB or RS-232 ports and the DMTH4 Control Panel is open on the computer screen.
Making a Phone Call
Telephone calls can be initiated from a wired remote control, from a Window’s based computer system connected to the DMTH4’s USB or RS-232 port, or from a standard single-line telephone system attached to the DMTH4 Telephone Set Jack.
Make a Telephone Call Using a Telephone Set
1.) Connect a telephone set to the rear panel Tele­phone Set connector and a cable between the telephone line and the rear panel Telephone Line input connector.
5.) To terminate the telephone call, click the “Discon­nect” button on the Activity tab.
Make a Telephone Call Using the Activity Tab
There are three ways to make a telephone call using the Activity tab: the Touch Tone Pad, the “Type in the Number to Dial” box or the Phone Book.
Using the Touch Tone Pad
1.) Click “Connect” on the Activity Tab. The Connect LED will light and the “Connect” button will change to “Disconnect.”
2.) Use the mouse to dial the desired telephone number.
3.) To terminate the telephone call, click the “Discon­nect” button on the Activity tab.
ConnectTouchTone Pad
Connect LED
Connect Telephone Set Here
Connect Telephone Line Input Here
2.) Click the DMTH4 Control Panel’s Activity tab.
3.) Use the telephone set to dial the desired number, then click “Connect”. The LED will light, indicating that DMTH4 telephone interface is connected and the “Connect” button will change to “Disconnect.”
4.) Placing the telephone handset back on the cradle automatically transfers all control to the DMTH4.
Connect
Connect LED
Rio Rancho, NM 19
Use the “Type the number to dial” box
1.) Click the “Type the number to dial” box, then use the computer keyboard to enter the telephone number. When finished, click “Dial” to connect the telephone interface and dial the number.
Connect
“Type in Number to Dial” Box
Connect LED
Dial
2.) To terminate the telephone call, click the “Discon­nect” button on the Activities tab.
Use the Phone Book
This procedure assumes that valid telephone numbers have been entered into the DMTH4’s Telephone Book. (The Tel/Codec tab is used to add or remove numbers from the Telephone Book.)
1.) Click “Telephone Book” in the Activities tab.
3.) To terminate the telephone call, click the “Discon­nect” button on the Activities tab.
Telephone Book Dial
Setting Up Automatic Telephone Answer and Automatic Disconnect
The DMTH4 can be configured to automatically answer incoming telephone calls and disconnect the telephone interface when it senses the call has been terminated by the calling party.
1.) Click the Tel/Codec tab and select the Telephone Interface tab.
2.) Click “Enable Auto Answer.”
Enable Auto Answer
Enable Auto Disconnect
Number of Rings
Tel/Codec Tab
Connect
Telephone Book
Connect LED
2.) Select the desired telephone number from the list and click “Dial” to connect the telephone interface and dial the number.
Telephone Interface
Ringing LED
3.) Set the desired number of rings before the DMTH4 answers the incoming call. This can be done by either entering a value from “1” (default) to “5”, or by using the up or down arrow buttons to increment or decrement the value in the “Nbr of rings” box.
LECTROSONICS, INC.20
When an incoming call is received the Ringing LED (on both the Tel/Codec Tab and the Activities Tab) will blink until the number of rings has been achieved, then extinguish to indicate that the Telephone Interface has connected.
4.) Click “Enable Auto Disconnect” to configure the DMTH4 so that the telephone interface automati­cally disconnects when it senses that the call has be terminated by the calling party.
Connecting to the CODEC Interface using the Activity Tab
It is assumed that the DMTH4 CODEC input and output signals on the rear panel have been connected to the video codec and that gain for each has been adjusted as needed.
1.) Click the “Connect” button to enable the connec­tion to the codec interface. The LED will light and the “Connect” button will change to “Disconnect.”
2.) To terminate the connection, click the “Disconnect” button.
Installation Guide
Codec Interface Tab
Connect
Connect LED
Tel/Codec Tab
Rio Rancho, NM 21
FCC Part 68 Compliance
This equipment complies with Part 68 of the FCC rules. On the rear panel of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company.
This equipment uses the following USOC jacks: RJ11C.
The REN is used to determine the quantity of devices which may be connected to the telephone line. Exces­sive REN on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total REN, contact the telephone company to determine the maximum REN for the calling area.
If this equipment causes harm to the telephone net­work, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your rights to file a com­plaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifica­tions in order to maintain uninterrupted service.
If trouble is experienced with this equipment, please contact Lectrosonics, Inc. at (800) 821-1121 for repair and/or warranty information. If the trouble is causing harm to the telephone network, the telephone company may request you remove the equipment from the network until the problem is resolved.
The following repairs can be done by the customer: No user serviceable parts inside.
This equipment cannot be used on telephone company­provided coin service.
Connection to Party Line Service is subject to state tariffs.
FCC Part 15 Compliance
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer­ence in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is con­nected.
Consult the dealer or an experienced radio/TV technician for help.
LECTROSONICS, INC.22
Installation Guide
Rio Rancho, NM 23
LIMITED ONE YEAR WARRANTY
The equipment is warranted for one year from date of purchase against defects in materials or workmanship provided it was purchased from an authorized dealer. This warranty does not cover equipment which has been abused or damaged by careless handling or shipping. This warranty does not apply to used or demonstrator equipment.
Shou
ld any defect develop, Lectrosonics, Inc. will, at our option, repair or replace any defective parts without charge for either parts or labor. If Lectrosonics, Inc. cannot correct the defect in your equipment, it will be replaced at no charge with a similar new item. Lectrosonics, Inc. will pay for the cost of returning your equipment to you.
This warranty applies only to items returned to Lectrosonics, Inc. or an authorized dealer, s
This Limited Warranty is governed by the laws of the State of New Mexico. It states the entire liablility of Lectrosonics Inc. and the entire remedy of the purchaser for any breach of warranty as outlined above. NEITHER LECTROSONICS, INC. NOR ANYONE INVOLVED IN THE PRODUCTION OR DELIVERY OF THE EQUIPMENT SHALL BE LIABLE FOR ANY INDIRECT, SPECIAL, PUNITIVE, CONSEQUENTIAL, OR INCIDENTAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THIS EQUIPMENT EVEN IF LECTROSONICS, INC. HAS BEEN ADVISED OF THE PO LECTROSONICS, INC. EXCEED THE PURCHASE PRICE OF ANY DEFECTIVE EQUIPMENT.
This warranty gives you specific legal rights. You may have additional legal rights which vary from state to state.
hipping costs prepaid, within one year from the date of purchase.
SSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL THE LIABILITY OF
581 Laser Road NE • Rio Rancho, NM 87124 USA • www.lectrosonics.com (505) 892-4501 • (800) 821-1121 • fax (505) 892-6243sales@lectrosonics.com
2 December, 2005