Crestron electronic DM-RMC-100 User Manual

Crestron DM-RMC-100
DigitalMedia
Room Controller
Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at:
Crestron Electronics, Inc.
15 Volvo Drive
Rockleigh, NJ 07647
1-888-CRESTRON
All brand names, product names and trademarks are the property of their respective owners.
©2008 Crestron Electronics, Inc.
Crestron DM-RMC-100 DigitalMedia™ Room Controller
Contents
DigitalMedia™ Room Controller: DM-RMC-100 1
Introduction ...............................................................................................................................1
Features and Functions................................................................................................ 1
Applications.................................................................................................................1
Specifications ..............................................................................................................3
Physical Description.................................................................................................... 4
Industry Compliance .................................................................................................10
Setup ........................................................................................................................................ 11
Network Wiring......................................................................................................... 11
Installation................................................................................................................. 11
Hardware Hookup .....................................................................................................13
Uploading and Upgrading........................................................................................................ 16
Establishing Communication.....................................................................................16
Firmware ...................................................................................................................17
Program Checks ........................................................................................................17
Problem Solving ......................................................................................................................18
Troubleshooting......................................................................................................... 18
Check Network Wiring..............................................................................................20
Reference Documents................................................................................................21
Further Inquiries........................................................................................................21
Future Updates ..........................................................................................................21
Return and Warranty Policies.................................................................................................. 22
Merchandise Returns / Repair Service ......................................................................22
CRESTRON Limited Warranty.................................................................................22
Operations & Installation Guide – DOC. 6743A Contents i
Crestron DM-RMC-100 DigitalMedia™ Room Controller
DigitalMedia™ Room Controller: DM-RMC-100

Introduction

The DigitalMedia™ (DM) Room Controller (RMC) is a digital media receiver and display controller designed to convert DigitalMedia to regular HDMI. It features a low-profile design perfect for installing behind flat panel screens and above ceiling mounted projectors.

Features and Functions

DigitalMedia receiver and display controller
HDMI display output
Choice of standard DM or DM Fiber inputs
USB HID keyboard/mouse port
10/100 Ethernet LAN port
RS-232, IR, digital in and relay control ports
Meets requirements for plenum-rated ceilings
Low-profile design
Mounts to a 1900, 2-gang, 4-inch square or Euro electrical box

Applications

The following diagram shows a DM-RMC-100 in a small classroom application.
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 1
DigitalMedia™ Room Controller Crestron DM-RMC-100
DM-RMC-100 in a Classroom Application
2 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller
For more information on this and other DM-RMC-100 applications, refer to the latest revision of the Crestron DigitalMedia
Design Guide (Doc.
4789), which is available from the Crestron website (www.crestron.com/manuals
).

Specifications

Specifications for the DM-RMC-100 are listed in the following table.
DM-RMC-100 Specifications
SPECIFICATION DETAILS
Power DMNet Power Usage 6 watts
(0.25 Amps @ 24 Volts DC) Environmental Temperature 41º to 104º F (5º to 40º C) Humidity 10% to 90% RH
(non-condensing) Heat Dissipation 21 BTU/Hr Dimensions Height 4.53 in (11.51 cm) Width 5.15 in (13.08 cm) Depth 1.41 in (3.58 cm) Weight 0.86 lbs (0.39 kg)
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 3
DigitalMedia™ Room Controller Crestron DM-RMC-100

Physical Description

This section provides information on the connections, controls and indicators available on your DM-RMC-100.
DM-RMC-100 Overall Dimensions (Front View)
5.15 in.
(13.08 cm)
1
2
4.53 in
(11.51 cm)
DM-RMC-100 Overall Dimensions (Bottom View)
6
7
89
10 11
3
4
5
1.41 in
(3.58 cm)
4 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller
DM-RMC-100 Overall Dimensions (Rear View)
12
13
14
Connectors, Controls & Indicators
# CONNECTORS1,
DESCRIPTION
CONTROLS &
INDICATORS
1 PWR LED (1) Green LED indicates
operating power supplied via DMNet control network.
2 DM LINK LED (1) Amber LED indicates a
connection to an upstream DM device.
(Continued on following page)
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 5
DigitalMedia™ Room Controller Crestron DM-RMC-100
Connectors, Controls & Indicators (Continued)
# CONNECTORS1,
DESCRIPTION
CONTROLS &
INDICATORS
3 VIDEO LED (1) Red/green dual color LED
indicates video signal presence and lock status: Green: Indicates that the device is receiving video
Red: Indicates no video Blinking Red/Green: Indicates
errors in the video stream.
4 CNTRL (1) Red/green dual-color LED
indicates Ethernet connection and control system communication status.
5 SETUP (1) Red LED and (1) miniature
recessed pushbutton, for Ethernet auto-discovery.
6 SENS
7 HDMI
(Continued on following page)
(1) 2-pin 3.5mm detachable terminal block; Digital/contact closure sensing input Rated for 0-24 Volts DC, referenced to GND Input Impedance: 2.2k ohms pulled up to 5 Volts DC Logic Threshold: 2.5 Volts DC nominal with 1 Volt hysteresis band.
(1) 19-pin Type A HDMI female; HDMI digital video/audio output
6 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller
Connectors, Controls & Indicators (Continued)
# CONNECTORS1,
CONTROLS &
INDICATORS
8 USB
9 RELAY 1, 2
10 COM
DESCRIPTION
(1) USB Type A female USB 1.1 port for mouse, keyboard, game controller, or other USB HID device.
(1) 4-pin 3.5mm detachable terminal block comprising (2) normally open, isolated relays; Rated 2 Amp, 50 Volts AC/DC MOV arc suppression across contacts.
(1) 5-pin 3.5mm detachable terminal block, bidirectional RS-232 port; Up to 115.2k baud, hardware and software handshaking support.
11 IR 1, 2
12 DM INPUT
2, 3
(Continued on following page)
(1) 4-pin 3.5mm detachable terminal block comprising (2) IR/Serial ports; IR output up to 1.1 MHz 1-way serial TT/RS-232 (0-5 Volts) up to 19200 baud.
(1) DM input composed of (2) 8-pin RJ-45 female, shielded; Connects to DM output of a DM switcher, transmitter, or other DM device via DM-CBL or CresCAT-D cable.4
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 7
DigitalMedia™ Room Controller Crestron DM-RMC-100
Connectors, Controls & Indicators (Continued)
# CONNECTORS1,
DESCRIPTION
CONTROLS &
INDICATORS
13 LAN3
14 DMNet
5, 6
1. Interface connectors for SENS, RELAY, COM and IR ports are provided with the unit.
2. The DM INPUT port consists of two separate RJ-45 connectors that are labeled D and M. The D port carries video signal. The M port carries data. Refer to the tables below, and on the following page, for the wires pin assignments.
(1) 8-wire RJ-45 female; 10BaseT/100BaseTX Ethernet switch port.
(1) 4-pin 3.5mm detachable terminal block, DMNet port; Connects to DMNet port of a DM switcher, transmitter, or other DM device via DM-CBL or CresCAT-D cable.4
D Port
PIN # SIGNAL DESCRIPTION
1 DATA D0+ HDMI Blue
2 DATA D0- HDMI Blue
4 DATA D1+ HDMI Green
5 DATA D1- HDMI Green
7 DATA D2+ HDMI Red
8 DATA D2- HDMI Red
3 CLK- HDMI Clock
6 CLK + HDMI Clock
8 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller
M Port
PIN # SIGNAL DESCRIPTION
1 +5V +5V Power
2 I2C_DATA HDCP & EDID Data
3 E_TX- 10/100BaseT Transmit
6 E_TX+ 10/100BaseT Transmit
4 E_RX- 10/100BaseT Receive
5 E_RX+ 10/100BaseT Receive
7 I2C_CLK HDCP & EDID Clock
8 +5V_RTN +5 Power Return
3. To determine which is pin 1 on the cable, hold the cable so that the end of the eight pin modular jack is facing away from you, with the clip down and copper side up. Pin 1 is on the far left.
4. For DigitalMedia wiring, use DM-CBL DigitalMedia Cable, CresCAT-D, or quality CAT5e/CAT6 cable. Do NOT use low-skew cable. Refer to the latest version of the Crestron DigitalMedia Design Guide (Doc. 4789) for complete wiring guidelines.
5. DMNet wiring is not compatible with Cresnet daisy chained.
6. Refer to the table below for the pinout of the 24 A B G port.
®
wiring. DMNet wiring cannot be
24 A B G Port
PIN # SIGNAL Color
24 24V DC Red
A DMNet + Orange
B DMNet - Grey
G Ground Black
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 9
DigitalMedia™ Room Controller Crestron DM-RMC-100

Industry Compliance

This unit has been manufactured to comply with UL’s Standards for Safety in Canada and the United States. Formal approval is pending.
As of the date of manufacture, the DM-RMC-100 has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling.
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
10 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller

Setup

Network Wiring

When wiring the DMNet network, consider the following:
®
NOTE: DMNet wiring and Cresnet
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
For DigitalMedia wiring, use DM-CBL DigitalMedia Cable,
CresCAT-D, or quality CAT5e/CAT6 cable. Do NOT use low­skew cable. Refer to the latest revision of the Crestron DigitalMedia Design Guide (Doc. 4789) for complete wiring guidelines.
wiring are not compatible.
CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (www.crestron.com/calculators
).
For more details, refer to “Check Network Wiring” on page 20.

Installation

To prevent overheating, do not operate this product in an area that exceeds the environmental temperature range listed in the table of specifications.
The following is required for installation:
DigitalMedia™ cable or CresCAT-D cable (not supplied)
terminated with RJ-45 connector for media signals and mini­phoenix connector for DMNet signals. Refer to “Network Wiring” on page 11.
Phillips screwdriver (not supplied)
Four #06-32 x 1/4" pan head Phillips screws (supplied)
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 11
DigitalMedia™ Room Controller Crestron DM-RMC-100
Metal mounting plate (supplied)
4-Pin connector plugs (supplied)
It is assumed that DigitalMedia cable (DM-CBL) has been fed through an installed two-gang electrical box, 85mm European or 1900 electrical box (not supplied) and wiring has been verified. Use the following procedure to install the DM-RMC-100.
1. Confirm that DMNet system power is OFF.
2. Attach supplied connector plugs according to the pinout on pages 8
and 9.
3. Attach metal mounting plate to electrical box using two Phillips
screws (not supplied).
4. Make DM-INPUT connections using DM-CBL.
Connect the RJ-45 terminated blue shielded DigitalMedia cable to the DM-INPUT D port.
Connect the yellow RJ-45 terminated CAT5e/CAT6 cable to the DM-INPUT M port.
Connect the DMNet cable with the supplied connector plug to the DM-RMC-100’s 24 A B G port.
5. Make the LAN connection to the DM-RMC-100’s LAN port using an Ethernet cable with an RJ-45 connector.
6. Attach DM-RMC-100 to mounting plate using four #06-32 x 1/4" Phillips screws (supplied) as shown in illustration on the following page.
12 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller
Mounting DM-RMC-100 into Electrical Box
METAL MOUNTING PLATE
(2019091)
DM-RMC-100
DRYWALL
MOUNTING SCREWS (4)
(2007215)

Hardware Hookup

Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “Network Wiring” on page 11 before attaching the 4-position terminal block connector. Apply power after all connections have been made.
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 13
DigitalMedia™ Room Controller Crestron DM-RMC-100
Hardware Connections for the DM-RMC-100 (Front View)
HDMI:
DISPLAY
HDMI
SENS:
CURRENT OR
MOTION SENSOR
MOUSE, KEYBOARD OR
GAME CONTROLLER
USB:
IR:
IR INPUT FOR
DEVICE CONTROL
RELAY:
SCREEN AND LIFT
CONTROL
COM:
RS-232 SERIAL FOR
DEVICE CONTROL
14 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller
Hardware Connections for the DM-RMC-100 (Back View)
LAN:
ETHERNET EQUIPPED
DISPLAY OR OTHER DEVICE
DM INPUT
DMNet
NOTE: Ensure the unit is properly grounded.
NOTE: For optimum performance, Crestron strongly recommends using
DM-CBL DigitalMedia
cable, available from Crestron. CresCAT-D or high-quality CAT5e/CAT6 wiring may also be used with varying performance. Do NOT use low-skew cable.
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 15
DigitalMedia™ Room Controller Crestron DM-RMC-100

Uploading and Upgrading

Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, firmware) can be transferred to the device.

Establishing Communication

Use Crestron ToolboxTM for communicating with the DM-RMC-100; refer to the Crestron Toolbox help file for details. There is a single method of communication: indirect communication.
Indirect Communication
PC RUNNING
CRESTRON TOOLBOX
SERIAL,
ETHERNET
OR USB
DM SWITCHER
DM-RMC-100
DMNet
DM-RMC-100 connects to a DigitalMedia
switcher via DMNet.
Establish communication between the PC and the DM switcher as described in the latest version of a DigitalMedia Switcher Operations Guide (Doc. 6755).
Use the Address Book in Crestron Toolbox to create an entry for the DM-RMC-100 using the expected communication protocol (Indirect). Select the Cresnet ID of the DM-RMC-100 and the address book entry of the control system or DM Switcher that is connected to the DM-RMC-100.
Display the DM-RMC-100’s “System Info” window (click the
icon); communications are confirmed when the device
information is displayed.
16 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller

Firmware

Firmware files may be distributed from programmers to installers or from Crestron to dealers. Firmware upgrades are available from the Crestron website as new features are developed after product releases. For details on upgrading, refer to the Crestron Toolbox help file.
Check the Crestron website to find the latest firmware. (New users may be required to register to obtain access to certain areas of the site, including the FTP site.)
Upgrade DM-RMC-100 firmware via Crestron Toolbox.
Establish communication with the DM-RMC-100 and display the “System Info” window.
Select Functions | Firmware… to upgrade the DM-RMC-100 firmware.

Program Checks

Using Crestron Toolbox, display the network device tree (Tools | Network Device Tree) to show all network devices connected to
the control system. Right-click on the DM-RMC-100 to display actions that can be performed on the DM-RMC-100.
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 17
DigitalMedia™ Room Controller Crestron DM-RMC-100

Problem Solving

Troubleshooting

The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative.
DM-RMC-100 Troubleshooting
TROUBLE POSSIBLE
CAUSE(S)
Device does not function.
Video LED does not illuminate.
Video LED blinks red and green.
Device is not communicating with the network.
Device is not receiving sufficient power.
Device is not receiving video signal.
Problem with video source.
CORRECTIVE
ACTION
Use Crestron Toolbox to poll the network. Verify network connection to the device.
Use the Crestron Power Calculator to help calculate how much power is needed for the system.
Ensure proper video signal is routed to repeater.
Verify source is operating.
(Continued on following page)
18 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller
DM-RMC-100 Troubleshooting (Continued)
TROUBLE POSSIBLE
CAUSE(S)
DM LINK LED
does not illuminate.
PWR LED does not illuminate.
Loss of functionality due to electrostatic discharge.
Device is not receiving DMNet signal.
Device is not receiving power.
Improper grounding.
CORRECTIVE
ACTION
Verify DMNet is properly attached.
Verify DMNet is properly attached.
Check that all ground connections have been made properly.
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 19
DigitalMedia™ Room Controller Crestron DM-RMC-100

Check Network Wiring

Use the Right Wire
Calculate Power
In order to ensure optimum performance over the full range of your installation topology, Crestron Certified Wire and only Crestron Certified Wire may be used. Failure to do so may incur additional charges if support is required to identify performance deficiencies because of using improper wire.
CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to do so could cause equipment damage or void the Crestron warranty.
CAUTION: Provide sufficient power to the system. Insufficient power can lead to unpredictable results or damage to the equipment. The EIG connector on the DM switcher is used to jumper in external power. Additional power is rarely required; switchers provide enough power for their maximum configuration of room controllers and repeaters. Please use the DMNet Power Calculator to help calculate how much power is needed for the system (www.crestron.com/calculators
).
Refer to the following table for maximum cable lengths for various cables.
Maximum Cable Length by Type
Cable Type: DM-CBL DigitalMedia Cable CresCAT-D Crestron Home®
CAT5 AV Cable
Maximum length between, before, or after
Resolution:
720p, 1080i, 1080p/24 200 ft (60 m) 450 ft (137 m) 150 ft (45 m) 400 ft (120 m)
1024x768 @75Hz 200 ft (60 m) 450 ft (137 m) 150 ft (45 m) 400 ft (120 m)
1080p/60 150 ft (45 m) 450 ft (137 m) 100 ft (30 m) 400 ft (120 m)
1280x1024 @75Hz 150 ft (45 m) 450 ft (137 m) 100 ft (30 m) 400 ft (120 m)
1920x1200 @60Hz 150 ft (45 m) 450 ft (137 m) 100 ft (30 m) 400 ft (120 m)
1600x1200 @60Hz 125 ft (38 m) 450 ft (137 m) 75 ft (23 m) 400 ft (120 m)
1080p/60 Deep Color 100 ft (30 m) 400 ft (120 m) Not Supported
repeaters
Maximum total length using up to 3 repeaters
Maximum length between, before, or after repeaters
Maximum total length using up to 3 repeaters
20 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller
NOTE: All Crestron certified DMNet wiring must consist of two twisted pairs. One twisted pair is the +24V conductor and the GND conductor and the other twisted pair is the A conductor and the B conductor.

Reference Documents

The latest version of all documents mentioned within the guide can be obtained from the Crestron website (www.crestron.com/manuals link will provide a list of product manuals arranged in alphabetical order by model number.
List of Related Reference Documents
DOCUMENT TITLE
Crestron DigitalMedia Design Guide DigitalMedia Switcher Operations Guide
). This

Further Inquiries

If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling Crestron at 1-888-CRESTRON [1-888-273-7876].
You can also log onto the online help section of the Crestron website (www.crestron.com/onlinehelp First-time users will need to establish a user account to fully benefit from all available features.
) to ask questions about Crestron products.

Future Updates

As Crestron improves functions, adds new features and extends the capabilities of the DM-RMC-100, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision.
Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download column.
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 21
DigitalMedia™ Room Controller Crestron DM-RMC-100

Return and Warranty Policies

Merchandise Returns / Repair Service

1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address.
2. Products may be returned for credit, exchange or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA.
3. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser.

CRESTRON Limited Warranty

CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered.
This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any.
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced or removed.
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party.
CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty.
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties.
Trademark Information
All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered trademark of Microsoft Corporation. Windows95/98/Me/XP/Vista and WindowsNT/2000 are trademarks of Microsoft Corporation.
22 DigitalMedia™ Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A
Crestron DM-RMC-100 DigitalMedia™ Room Controller
This page is intentionally left blank.
Operations & Installation – DOC. 6743A DigitalMedia
Room Controller: DM-RMC-100 23
Crestron Electronics, Inc. Operations & Installation Guide – DOC. 6743A
15 Volvo Drive Rockleigh, NJ 07647 (2022552) Tel: 888.CRESTRON 12.08 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.
Loading...