INET-IOEX-IRCOM
infiNET EX® Wireless IR/RS-232 Control Module
The Crestron® INET-IOEX-IRCOM control module provides an IR and
RS-232 control interface for video displays, AV components, small
appliances, and other equipment. The control module includes two
discrete IR ports and one bidirectional RS-232 port.
The control module communicates with a Crestron 3-Series® control
system via the infiNET EX® wireless network, allowing for control
and monitoring of remote devices without running wires or installing
conduit.
NOTE: The INET-IOEX-IRCOM is compatible only with Crestron
3-Series control systems.
Check the Box
Item Qty
INET-IOEX-IRCOM 1
Connector, 2-Pin (P/N 2003574) 1
Connector, 3-Pin (P/N 2003575) 1
IR Emitter, with Terminal Block Connector, IRP2
(P/N 4500152)
Power Pack, 5 Vdc, 1.2 A, 100-240 Vac, Flying Leads
(P/N 2045867)
2
1
Install the Device
The INET-IOEX-IRCOM may be mounted onto any flat surface using
three mounting screws (not included).
NOTE: For best results, install the device in an location where it will
not receive interference from nearby RF sources, obstructions, and
metal surfaces.
INET-IOEX-IRCOM
Mounting
Connect the Device
Make the necessary connections as called out in the following
illustration.
NOTE: The included IR emitters may be used to provide a one-way IR
control interface to an IR-controllable device. For more information,
refer to the IRP2 Installation Guide (Doc. 8186) at
www.crestron.com/manuals.
S/G (1–2):
To IR devices
(via included
IR emitters)
G/TX/RX:
To any
RS-232
device
PWR:
From included
5 Vdc, 1.2 A
power pack
Connect to an infiNET EX Network
The INET-IOEX-IRCOM must be acquired by an infiNET EX wireless
gateway or by a control system with a built-in infiNET EX gateway
(both not included) before it may be used with a 3-Series control
system.
Use the procedures below to join or leave an infiNET EX network and
to verify communications between the device and the control system.
NOTE: The INET-IOEX-IRCOM may be acquired only by one network.
Join the infiNET EX Network
1. Enter Acquire mode using one of the following methods:
• Press the ACQUIRE button on the infiNET EX gateway.
• Enter Acquire mode from Crestron Toolbox™ software. For
more information, refer to the Crestron Toolbox help file.
NOTE: In an environment where there are multiple gateways
installed, place only one gateway in Acquire mode at a time.
2. Press the SETUP button three times, and then press and hold
the SETUP button (press-press-press-press+hold) until the
LED on the device flashes once. This process may take up to ten
seconds to complete.
NOTE: If the INET-IOEX-IRCOM was previously acquired to
another gateway, instead press the SETUP button three
times, and then press and hold the button (press-press-press-
press+hold) for over ten seconds.
3. Release the SETUP button to start the acquire process. The LED
flashes slowly to show that the device is actively scanning the
infiNET EX network.
4. Confirm the status of the acquire process:
• If the INET-IOEX-IRCOM is acquired by the infiNET EX
network, the LED lights for five seconds.
• If the INET-IOEX-IRCOM is not acquired by the infiNET EX
network, The LED flashes rapidly for several seconds. Press
the SETUP button to cancel the acquire process. Ensure the
gateway is in Acquire mode and that the INET-IOEX-IRCOM
is in range before attempting the acquire process again.
5. After the process is complete, remove the gateway from Acquire
mode as described by its documentation.

Leave the infiNET EX Network
1. Verify that the INET-IOEX-IRCOM is not within range of a
gateway that is in Acquire mode.
2. Press the SETUP button three times, and then press and hold
the SETUP button (press-press-press-press+hold) until the
LED on the device flashes once. This process may take up to ten
seconds to complete.
3. Release the SETUP button. The LED flashes quickly to indicate
that the INET-IOEX-IRCOM has left the infiNET EX wireless
network.
4. Press the SETUP button to acknowledge that the device has left
the network and to stop the flashing LED.
Verify the Communications Status
To check the communications status of the INET-IOEX-IRCOM, press
the SETUP button three times, and then press and hold the button
(press-press-press-press+hold) for up to two seconds.
The LED blinks to indicate the communications status as described in
the table below.
LED COMMUNICATIONS STATUS
The LED turns on for five
seconds.
The LED blinks three
times.
The LED blinks twice. The device was previously joined to the
The LED blinks once. The device is not joined to the network.
The device is communicating with the
control system.
The device is communicating with
the gateway, but the gateway is not
communicating with the control system.
network but is not communicating with
the gateway.
For Additional Information
Scan or click the QR code for detailed product information.
INET-IOEX-IRCOM
Compliance and Legal
Original Instructions: The U. S. Engl ish version of this document is t he original in stru ctio ns.
All other languages are a trans latio n of the origina l instruct ions.
As of the date of ma nufac ture, t he prod uct ha s been te sted and found to compl y with
specifications for CE marking.
Federal Communications Commission (FCC) Compliance Statement
This dev ice complies with par t 15 of the FCC Rules. Op eration is subj ect to t he foll owing
condit ions: ( 1) This d evice m ay not cause harmful interference and (2) this device m ust
accept any inter ference received, includin g inter feren ce that m ay cause undes ired op eration.
CAUTION: Changes or modifi catio ns not expressly approved by the manufacturer
responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This e quipm ent has b een tested an d found to comply w ith the limit s for a Class B
digital device, pursuant to par t 15 of the FCC Rules. Th ese limits are d esign ed to provide
reasonable protection against harmful interference in a residential installation. This
equipm ent gen erates, uses and can radiate radio freq uenc y energ y and, if n ot installed
and used in accord ance wi th the instru ctio ns, ma y cause harmful i nterference to radio
communicatio ns. However, there i s no guarantee th at interfere nce will not occu r in a
part icular installatio n. If this equipment does caus e harmf ul inter ference to radio or
televi sion re ceptio n, which can be de termined by tur ning th e equip ment of f and on , the user
is encouraged to try to co rrec t the interference by one or more of the fol lowing measu res:
• Reori ent or relocate t he receiving a ntenna .
• Increase the separation between the equipment and receiver.
• Conne ct the equipment into an outl et on a circ uit dif feren t from that to whic h the
receiver is connected.
• Consu lt the de aler or an experienced radio/ TV technici an for he lp.
Industry Canada (IC) Compliance Statement
CAN ICE S-3 (B)/N MB-3 (B)
RF Expo sure (OE T Bull etin 65)
To comply wit h FCC’s R F expos ure limi ts for g eneral popul ation /uncontrolled exposure, thi s
transm itter must be i nstalled to pro vide a separat ion dis tance of at leas t 20 cm fro m all
perso ns and must not be coloca ted or op erati ng in conj unct ion wit h any other anten na or
transmitter.
The product wa rrant y can be fo und at www.crestron.com/warranty.
The spe cific patent s that cover Crestron p roduc ts are l isted at www.crestron.com/legal/
patents.
Certa in Cres tron products contain open source s oft ware. For speci fic informat ion, please
visit w ww.crestron.com/opensource.
Crestron, the Crestron logo, 3-Ser ies, Crestro n Toolbox, infiN ET EX , and the infiN ET EX lo go
are eith er trad emark s or registere d trademark s of Crestron Ele ctro nics , Inc. in the Uni ted
States an d/or other countries. O ther tr adema rks, registered tradema rks, and trade names
may be us ed in this docum ent to refer to either the e ntiti es claiming th e marks and names
or their products . Crest ron disclaims a ny propr ietar y interest in the mark s and nam es of
others. Crestron is not responsible for errors in typography or photography.
©2019 Crestron Electronics, Inc.
Crestron Electronics, Inc.
15 Volvo Dr ive, Rockleig h, NJ 07647
Tel: 888.CRESTRON
Fax: 201.767.7576
www.crestron.com
Quick Start - Doc. 7476G
Specifications subject to
change without notice.
(2053349)
02.1 9