Crestron CNXRMAK User Manual

Rack Mount Kit: CNXRMAK

Description

The CNXRMAK is a 2-space rack mount kit that used to install up to three Crestron C2N-HBLOCK Cresnet
distribution blocks or three CNPWS-75 Cresnet power supplies (or any combination thereof) into a 19-inch EIA equipment rack. The kit consists of the black finished 2U mounting plate (part # 2004738, shown below) and twelve (12) 6-32, 3/8” pan head Phillips screws (part # 2007225). The only tools required for installation are a #2 Phillips 1/4-inch hex bit and an inch-pound torque driver.
CNXRMAK Physical Views
19.00 in
(48.26 cm)
3.50 in
(8.89 cm)
CNXRMAK
Front View
Rear View
ZA11325
MADE IN THE U.S.A.
CNXRMAK
C000000
THICKNESS = 0.12 in (0.30 cm)
As of the date of manufacture, this unit has been tested and found to comply with specifications for CE marking.

Rack Mounting

WARNING: To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
The unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the
heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing
the unit in the rack.
Installation Guide – DOC. 8156A Rack Mount Kit: CNXRMAK 1
Rack Mount Kit Crestron CNXRMAK

Installation Instructions

Component Mounting Locations

The CNXRMAK can accommodate up to three C2N-HBLOCKs or CNPWS-75s or any combination of each. Three sets of mounting holes have been drilled into the mounting plate for each component. As shown below, C2N-HBLOCK (s) and/or CNPWS-75(s) are mounted to the holes in the appropriate location(s).
C2N-HBLOCK and CNPWS-75 Mounting Locations
C2N-HBLOCK
CNPWS-75
C2N-HBLOCK
CNPWS-75
C2N-HBLOCK
CNPWS-75

Component Mounting and Rack Installation

Refer to the procedure below and complete the following steps for proper installation of a C2N-HBLOCK (C2N-HBLOCKmounting plate must be removed) or CNPWS-75 onto the CNXRMAK and then into a rack.
1. Position the CNXRMAK mounting plate so that the rear of the plate faces the rear of the component. (The barcode label should be at the bottom of plate, facing the component.)
2. As shown in the diagram below, align mounting holes on the plate with threaded holes in the rear of the component. Using a #2 Phillips 1/4-inch hex bit and an inch-pound torque driver, install four screws (supplied) and tighten to 11-inch pounds (1.24 newton-meters) to secure component.
C2N-HBLOCK Installation CNPWS-75 Installation
U
F
S
E
E
S
F
U
U
F
S
E
NOTE: BARCODE LABEL ON REAR OF PLATE
NOTE: BARCODE LABEL ON REAR OF BRACKET
3. If installing another C2N-HBLOCK or CNPWS-75, repeat this procedure. If not installing another component, refer to the diagram on the next page and install the CNXRMAK into rack with components facing inward. (Rack mounting hardware is not supplied.)
2 Rack Mount Kit: CNXRMAK Installation Guide – DOC. 8156A