The table below provides a summary of leading specifications for the CNXIR-8.
Dimensions are approximations rounded to the nearest hundredth unit.
Leading Specifications of the CNXIR-8
SPECIFICATIONDETAILS
Power Requirements
IR Output
Output Signal Levels
SIMPL Windows
CNX Operating System
CNX Monitor
Dimensions
As of the date of manufacture, the unit has been tested and found to comply with
specifications for CE marking.
24 VDC, network power; 3 Watts
Up to 1.12MHz
0 to 5VDC
(compatible with most RS-232 input devices)
Version 1.19.08 or later
Version 5.01.00 or later
Version 2.00 or later
Height: 0.980 in (2.490 cm)
Width: 5.000 in (12.700 cm)
Setup
Installation
Items required to install the CNXIR-8 are already attached to the unit. The only
tools required are a Phillips tip screwdriver and a grounding strap. Follow the
assembly procedure below.
CAUTION: The CNXIR-8 contains electrostatic sensitive devices (ESD); observe
precautions for handling ESDs to avoid damaging the card.
NOTE: If installing the CNXIR-8 into a CNMSX-AV, it is assumed that the
CNXCAGE has been installed.
1. Disconnect power from the CNMSX.
2. Use the Phillips tip screwdriver and remove two screws and blank
faceplate from the control system.
3. Align the CNXIR-8 with the card guides in the open slot and slide the
expansion card into postion.
4. Firmly press both ends of the CNXIR-8 faceplate to seat the expansion
card into the control system connector.
5. Tighten the thumb-nail screws to secure the CNXIR-8 to the control
A basic CNXIR-8 SIMPL program is shown below in block diagram form. For this
example, the CNXIR-8 occupies slot #1 of a CNMSX-PRO. Assume a touchpanel
interfaces directly with two IR drivers. Port A contains a Sony ST-92TV IR driver
and Port C contains a Panasonic AG-1980 VCR IR driver. Both drivers are obtained
from the Crestron Database. The touchpanel directly activates buttons on the IR
drivers, which closely simulates a user pressing buttons on the remote. As long as a
button is held on a touchpanel, the IR command tied to that button is sent out.
Block Diagram of CNXIR-8
How to Create the Program
Use the Configuration Manager workspace in SIMPL Windows to select and
configure all the devices that need to be included into the system. For this example,
add a CNXIR-8 to slot #1 of the CNMSX-PRO. Also add a CT-3000 to the system;
its NET ID must be set to 03, shown on the next page.
NOTE: SIMPL Windows v1.19.08 or later is required to program the CNMSXPRO. If using an earlier version of SIMPL Windows, Crestron recommends a
SIMPL Windows and operating system upgrade.
Graphical Detail View of Touchpanel in SIMPL Windows’ Programming Manager
Expand the Central Control Modules folder and the CNXIR-8 folder. Double click
on the two ports of the CNXIR-8 for a detail view (alternatively CTRL+D or drag
and drop into Detail View). Assign signals as shown on the next page.
The table below provides corrective action for possible trouble situations. If further
assistance is required, please contact a Crestron technical support representative.
CNXIR-8 Toubleshooting
TROUBLE
POSSIBLE
CORRECTIVE ACTION
CNXIR-8 does
not function.
A particular IR
function.
CNX Control System
is not receiving
power.
Circuit card is not
properly seated in
slot.
Programming error.Check SIMPL Windows program.
CNIRP wiring was
extended and polarity
was reversed.
Incorrect or missing
driver for IR device.
Programming error.Check SIMPL Windows program.
Verify power to CNX Control System.
Verify CNXIR-8 is properly inserted into
CNX Control System slot per procedures in
this Operations Guide.
Verify proper polarity on CNIRP wiring.
First, install appropriate driver using SIMPL
Windows.
Second, verify functionality of driver using
Infrared/Serial Learner.
Further Inquiries
If after reviewing this Operations Guide for the CNXIR-8, you cannot locate
specific information or have questions, please take advantage of Crestron's award
winning technical support team by calling:
• In the US and Canada, call Crestron’s corporate headquarters at
1-888-CRESTRON [1-888-273-7876] or 1-201-767-3400.
• In Europe, call Crestron International at +32-15-50-99-50.
• In Asia, call Crestron Asia at +852-2341-2016.
• In Latin America, call Crestron Latin America at +525-574-15-90.
For local support from exclusive Crestron factory-trained personnel call:
• In Australia, call Soundcorp at +613-941-61066.
• In New Zealand, call Amber Technologies at +649-410-8382.
Page 13
CRESTRON
Return and Warranty Policies
Merchandise Returns / Repair Service
1. No merchandise may be returned for credit, exchange, or service
without prior authorization from CRESTRON. To obtain warranty
service for CRESTRON products, contact the factory and request an
RMA (Return Merchandise Authorization) number. Enclose a note
specifying the nature of the problem, name and phone number of
contact person, RMA number, and return address.
2. Products may be returned for credit, exchange, or service with a
CRESTRON Return Merchandise Authorization (RMA) number.
Authorized returns must be shipped freight prepaid to CRESTRON,
Cresskill, N.J., or its authorized subsidiaries, with RMA number
clearly marked on the outside of all cartons. Shipments arriving
freight collect or without an RMA number shall be subject to refusal.
CRESTRON reserves the right in its sole and absolute discretion to
charge a 15% restocking fee, plus shipping costs, on any products
returned with an RMA.
3. Return freight charges following repair of items under warranty shall
be paid by CRESTRON, shipping by standard ground carrier. In the
event repairs are found to be non-warranty, return freight costs shall
be paid by the purchaser.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. warrants its Cresnet II products, denoted by a
"CN" prefix model number, to be free from manufacturing defects in materials and
workmanship for a period of three (3) years from the date of shipment to purchaser.
Disk drives and any other moving or rotating mechanical parts are covered for a
period of one (1) year. CRESTRON warrants all its other products for a period of
one year from the defects mentioned above, excluding touchscreen display
components which are covered for 90 days. Incandescent lamps are completely
excluded from Crestron's Limited Warranty. CRESTRON shall, at its option, repair
or replace any product found defective without charge for parts or labor. Repaired or
replaced equipment and parts supplied under this warranty shall be covered only by
the unexpired portion of the warranty.
CRESTRON shall not be liable to honor warranty terms if the product has been
used in any application other than that for which it was intended, or if it has been
subjected to misuse, accidental damage, modification, or improper installation
procedures. Furthermore, this warranty does not cover any product that has had the
serial number altered, defaced, or removed.
This warranty shall be the sole and exclusive remedy to the purchaser. In no event
shall CRESTRON be liable for incidental or consequential damages of any kind
(property or economic damages inclusive) arising from the sale or use of this
equipment. CRESTRON makes no other warranties nor authorizes any other party
to offer any warranty, expressed or implied, including warranties of merchantability
for this product. This warranty statement supersedes all previous warranties.
NOTE: All brand names, product names, and trademarks are the property of their
respective owners. Windows and Windows95 are the property of Microsoft