Crestron CLC-FANDELVEX-W Installation Manual

Page 1
CLC-FANDELVEX-W
inNET EX® Fan Controller Installation Guide
Description
The Crestron® CLC-FANDELVEX-W is an inNET EX fan and light controller. The compact design allows it to securely t in a fan canopy.
Refer to the following table for specications for the CLC-FANDELVEX-W.
SPECIFICATION DETAILS
Current Ratings
Fan Load 120 Vac, 0.8 A, 60 Hz
Light Load 120 Vac, 200 W, 60 Hz
(100 W Max for CFL or LED Loads)
Load Types Dimmed incandescent, CFL, LED, tungsten,
electronic low voltage
NOTE: Do not connect to magnetic low-voltage type loads.
Environmental
Temperature 32° to 104 °F (0° to 40 °C)
Humidity 10% to 90% RH (noncondensing)
The CLC-FANDELVEX-W has a multifunction ACQUIRE button and STATUS, LIGHT, and FAN LEDs. Their functions are described below.
The ACQUIRE button:
• Allows the device to connect to the inNET EX network. Refer to the “Wireless Communications” section for details.
• Press to toggle the dimming load between on and off.
• Press to exit Identify mode.
The STATUS LED:
• Illuminates green to indicate it is receiving power.
• Flashes green to indicate inNET EX acquire status.
• Flashes red to indicate error conditions.
NOTE: The green LED extinguishes after 1 minute. The red LED extinguishes when the error is cleared.
The LIGHT LED:
• Illuminates to indicate that a command was received to turn on the light.
NOTE: The LIGHT LED extinguishes after 1 minute.
The FAN LED:
• Illuminates to indicate that a command was received to turn on the fan.
NOTE: The FAN LED extinguishes after 1 minute.
Installation
WARNING: To avoid re, shock, or death, turn off the power at the circuit breaker or fuse and test that the power is off before wiring!
WARNING: To reduce the risk of electric shock, install the CLC-FANDELVEX-W with an isolating wall control or switch.
CAUTION: To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle.
NOTES: Observe the following points:
• Install and use this prodct in accordance with appropriate electrical codes and regulations.
• A licensed electrician should install this product.
• Do not install in a damp or moist environment. This product is for indoor use only.
NOTE: Before using the CLC-FANDELVEX-W, ensure the device is using the latest rmware. Check for the latest rmware for the CLC-FANDELVEX-W at www
. crestron . com / rmware. Firmware is loaded onto the device using Crestron
Toolbox™ software.
NOTE: Refer to the documentation for the fan for proper installation or disassembly and reassembly.
NOTE: Using the fan’s hardware controls, set the fan to high speed and the lights to on.
NOTE: Remove any pre-installed fan remote controller before installing the
CLC-FANDELVEX.
Install the CLC-FANDELVEX-W after all connections have been made. The CLC-FANDELVEX-W can be inserted into most common fan canopies. Refer to the following illustration for details.
Ceiling Fan Mounting Bracket
CLC-FANDELVEX-W
To Junction Box
Additional Resources
Visit the product page on the Crestron website (www.crestron.com) for additional information and the latest rmware updates. Use a QR reader application on your mobile device to scan the QR image.
CLC-FANDELVEX-W Installed in Fan Canopy
To Junction Box
Page 2
Wiring
The module has ying leads for power and control. Power enters the CLC-FANDELVEX-W and passes fan control and light power to the fan. The CLC-FANDELVEX-W has one black (hot) and one white (neutral) power input. It also has a red (fan), blue (light), and white (neutral) output for control.
NOTE: Refer to the documentation for the fan to ensure proper fan wiring.
Wiring the CLC-FANDELVEX-W
Wall Switch
AC 110 V 60 Hz
Power Input
Black (Hot)
Blue (Light Power)
Power and Control Output
Blue
FAN WIRE TYPICAL COLOR
Fan Black
Lights Blue
Neutral White
Black
White
MODULE WIRE CONNECTION
White Neutral wires to
Black Connects to the
Red Connects to the
Blue Connects to the
White
White (Neutral)
Red (Fan Power)
White
(Neutral)
Black (Motor)
the junction box and fan
live wire.
fan motor wire.
lights.
Wireless Communications
The device connects to the Crestron network via the inNET EX communications protocol. Use the procedures outlined below to join or leave an inNET EX network and to verify communications between the device and the control system.
Joining an inNET EX Network
Before a device can be used in a lighting system, it must rst join an inNET EX network. To join an inNET EX network, the device must be acquired by an inNET EX gateway.
NOTE: A device can be acquired by only one gateway.
1. Put the inNET EX gateway into Acquire mode from the unit itself or from Crestron Toolbox. Refer to the gateway’s manual at www.crestron.com/manuals for details.
NOTE: In an environment where multiple gateways are installed, only one gateway should be in Acquire mode at any time.
2. Put the device into Acquire mode.
a. Tap the ACQUIRE button three times and then press and hold it down
(tap-tap-tap-press+hold) until the green STATUS LED on the device blinks once (this can take up to 10 seconds).
b. Release the button to start the acquire process. The green STATUS LED blinks
slowly to show that the device is actively scanning the inNET EX network.
• The green STATUS LED turns on for 5 seconds to show that the device has
been successfully acquired by the infiNET EX network.
• The green STATUS LED blinks fast to indicate that the device was not
successfully acquired by the infiNET EX network. Tap the ACQUIRE button to acknowledge the failure. Ensure the gateway is in Acquire mode and within range before attempting the acquire process again.
3. Once all devices have been acquired, take the gateway out of Acquire mode. Refer to the gateway’s manual for details.
Leaving an inNET EX Network
To leave an inNET EX network, put the device into Acquire mode, as described in “Joining an inNET EX Network” above, when no gateway is in Acquire mode.
Verifying Communications Status
To check the communications status of the device, tap the ACQUIRE button three times and then press and hold it down (tap-tap-tap-press+hold) for up to 2 seconds. The green STATUS LED blinks to indicate the communications status. Refer to the following table for details.
LED COMMUNICATIONS STATUS
Turns on for 5 seconds The device is communicating with the control system.
Blinks three times The device is communicating with the gateway, but the
gateway is not communicating with the control system.
Blinks twice The device was previously joined to the network but is
not communicating with the gateway.
Blinks once The device is not joined to the network.
Error States
The LED blinks a pattern to indicate an error. The patterns listed below are described as 2-1 or 2-3. For a 2-1 error, an overcurrent condition, the LED blinks twice, pauses for 1 second, blinks once, pauses for two seconds, and then repeats until the error is corrected. During an overcurrent condition, the lights will turn off. Sending a new light level corrects the overcurrent condition.
For a 2-3 error, an overtemperature error, the LED blinks twice, pauses for 1 second, blinks three times, pauses for two seconds, and then repeats until the error is corrected. During an overtemperature condition, the light and fan will turn off. During an overtemperature error, requests to turn on the load or fan are ignored. The error clears when the device cools.
NOTE: The overtemperature error is not saved in nonvolatile memory and is cleared when power is cycled.
Regulatory Compliance
This product is Listed to applicable UL Inc.
Conformité Reglementaire
Ce produit est homologué selon les normes et les exigences UL applicables par Underwriters Laboratories Inc.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
®
Standards and requirements by Underwriters Laboratories
Industry Canada (IC) Compliance Statement
CAN ICES-3(B)/NMB-3(B)
The product warranty can be found at www.crestron.com/warranty.
The specic patents that cover Crestron products are listed at patents.crestron.com.
Certain Crestron products contain open source software. For specic information, please visit www.crestron.com/opensource.
Crestron, the Crestron logo, Crestron Toolbox, inNET EX, and the inNET EX logo are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2016 Crestron Electronics, Inc.
Crestron Electronics, Inc. Installation Guide - DOC. 7705B
15 Volvo Drive Rockleigh, NJ 07647 (2045179) Tel: 888.CRESTRON 06.16 Fax: 201.767.7576 Specications subject to www.crestron.com change without notice.
Loading...