Crestron CCS-UC-1-AV-PLUS Quick Start Manual

Quick Start
LAN
Laptop
LAN
CCS-UC-1 W/PS, CCS-UC-1-AV W/PS, CCS-UC-1-AV-PLUS
Crestron Mercury® Tabletop Unified Communications Conference System Solutions
The CCS-UC-1 W/PS, CCS-UC-1-AV W/PS, and CCS-UC-1-AV-PLUS are Unified Communications (UC) conference system solutions centered around the CCS-UC-1 UC tabletop console. The CCS-UC-1 W/PS provides audio conference capabilities while the CCS-UC-1-AV W/PS and CCS-UC-1-AV-PLUS add video capabilities to a conference room.
Check the Box
Item Qty
CCS-UC-1 W/PS , CCS-UC-1-AV W/PS, or CCS-UC-1-AV-PLUS 1
Tie Wrap (P/N 2047935) 3
CCS-UC-1-AV W/PS
CCS-UC-1-AV-PLUS
Connect the Device
The CCS-UC-1 should be wired for its intended use. Refer to the following table to determine what is necessar y for the specific installation.
Required Wiring Scenario
General Wiring Wiring with SMK Zoom Conference Room
Route cables through swivel tube plate No Yes Optional
Service loops Yes No Yes
Cable Retention Plate Yes Yes Yes
Feed Cables Through the Swivel Tube Plate (Installations with CCS-UCA-SMK only)
If the CCS-UCA-SMK swivel mount kit is used in the installation, refer to the CCS-UCA-SMK DO Guide (Doc. 7882).
NOTE: If the CBL-HD-THIN-HS-6, 6 ft HDMI input cable and the A - Micro B, 6 ft USB 2.0 cable are to be routed to the front of the CCS-UC-1, do
not route the cables through the swivel tube plate.
Hardware Hookup
When wiring the CCS-UC-1 to external devices, it is highly recommended to use the cables that ship with the device. Each kit ships with every cable needed for most rooms. The cables and accessories have been designed so that a service loop can be implemented prior to the cables leaving the chassis body of the device (if necessar y). If an extension option is required, Crestron solutions should always be used and can be found under the MODELS & ACCESSORIES tab at www.crestron.com/products/model/CCS-UC-1.
CCS- U C-1 W/ PS
Laptop
via included USB cable
Ground
Corporate
network
USB/ACC:
For future use
AC power pack
24 Vdc, 2.5 A
100-240 V 50/60 Hz:
From ac
power outlet
Install the Cable Retention Plate
Remove® the adhesive backing from the cable retention plate and install it as shown in the following diagram. The cable retention plate is designed to fit at the cable exit location at the rear of the chassis and provides three tie-down points for cables connected to the device.
CAUTION: When turning over the device, place the device on a soft surface to avoid damage.
NOTE: If the CCS-UCA-SMK swivel mount kit is to be used, use the cable retention bracket included with the CCS-UCA-SMK. For details, refer to
the CCS-UCA-SMK DO Guide (Doc. 7882) at www.crestron.com/manuals.
Install cable
retention
plate here
NOTE: Before securing cables, ensure the cable retention plate is firmly attached.
Cable retention
plate installed
CCS-UC-1
AUX:
Ethernet to SIP
or PoE+
via included
Ethernet cable
10BASE-T/100BASE-TX
CCS-UC-1-AV W/PS and CCS-UC-1-AV-PLUS
Display device
via CBL-HD-20
and IR or serial control
Ground
Corporate
network
10BASE-T/100BASE-TX
or PoE+
via included
Ethernet cable
AUX:
Ethernet to SIP
CCS-UCA-MIC Microphone pods (sold separately)
Must connect AC power pack to CCS-UC-1
via included USB cable
CCS-UCA-MIC Microphone pods
(sold separately)
Must connect AC power pack to CCS-UC-1
USB/ACC:
For future use
24 Vdc, 2.5 A
AC power pack
CCS-CAM-USB-F-100
CCS-UC-1-AV W/PS
(
100-240 V 50/60 Hz:
From ac
power outlet
OR
CCS-CAM-USB-F-300
CCS-UC-1-AV PLUS
only)
(
Connect with UC-HUB-USB
only)
Zoom Room Hookup
power outlet
Must connect AC power pack to CCS-UC-1
LAN
Standard Wiring Zoom Wiring
Route CBL-USB-A-BMICRO-6
Route CBL-HD-THIN-HS-6 cable here
Zoom Rooms™ PC
via included USB cable
Insert included USB
stick here.
3. Connect the CBL-USB-A-BMICRO-6 cable to the USB-B port, and insert it into the channel track labeled “USB” to route it to the front of the
device. For details, refer to the following diagram.
cable here
Ground
Corporate
network
CCS-UCA-MIC Microphone pods (sold separately)
24 Vdc, 2.5 A
AC power pack
100-240 V 50/60 Hz:
From ac
NOTE: Refer to the Zoom Room Kit Installation Guides (Docs 8229 and 8230) for hardware hookup details.
To make connections to the CCS-UC-1, perform the following procedure:
1. (CCS-UC-1-AV W/PS and CCS-UC-1-AV-PLUS only) Connect the CBL-HD-20 cable to the HDMI OUT port. Use the provided tie wrap to secure
this cable to the center position on the cable retention plate, leaving enough cable to allow for a 3-inch ser vice loop. Refer to the following photo.
USB cable
HDMI cable
Service loops Service loops
Tie wrap
Cable Retention Plate
NOTE: If the CCS-UCA-SMK is used, connect the HDMI extension cable included with the CCS-UCA-SMK to the HDMI OUT port. Refer to the
CCS-UCA-SMK DO Guide (Doc. 7882).
2. Connect the Ethernet cable and the USB camera cable (CCS-UC-1-AV W/PS and CCS-UC-1-AV-PLUS only) to the LAN and USB/CAM ports
respectively.
NOTES:
If necessary, use the CBL-USB-A-EXT-15 extension cable to extend the connection to the camera.
For the CCS-UC-1-AV-PLUS, connect the camera to the UC-HUB-USB, and connect the UC-HUB-USB to the USB/CAM port on the
CCS- U C-1 .
4. (CCS-UC-1-AV and CCS-UC-1-AV-PLUS only) Connect the CBL-HD-THIN-HS-6 cable to the HDMI IN port, and insert the cable into the channel
track labeled “HDMI” to route it to the front of the device. Refer to the diagram in step 3.
5. Bundle the Ethernet, USB camera (CCS-UC-1-AV and CCS-UC-1-AV-PLUS only), and the power supply cables together and use the provided
tie wrap to secure the bundle to one of the two remaining outside positions on the cable retention plate, leaving enough cable to create a 2- to 3-inch service loop. Refer to the photo in step 1.
NOTES:
If the system design dictates that the USB-B Laptop and HDMI Input cables should not exit through the front but at the rear with all
other cables, the cables can be added to the same bundle with the other Ethernet/USB cables or they can be positioned together into their own bundle. Make sure to leave enough cable for a 2- to 3- inch ser vice loop before exiting the rear of the device.
If the CCS-UCA-SMK is used, do not create a service loop.
Power Supply
The CCS-UC-1 can receive power over PoE+ (IEEE 802.3at) or the PW-2420RU power pack. A standard PoE switch cannot provide sufficient power to the device.
The PW-2420RU power pack must be connected to the CCS-UC-1 if CCS-UCA-MIC microphone pods are to be used.
Observe the following when powering the CCS-UC-1 by PoE+:
PoE-type networks connected to these ports are for intrabuilding use only and should not be connected to lines that run outside of the
building in which this product is located.
When powering the CCS-UC-1 with PoE+ (IEEE 820.3at), PoE+ switches that utilize Link Layer Discovery Protocol (LLDP) must have LLDP
enabled. Please coordinate with the IT Administrator who manages network infrastructure at the customer site to make sure the PoE+ ports have LLDP enabled. For more information, refer to the CCS-UC-1 Supplemental Guide (Doc. 7844).
Configure the Device
For details on configuring the device, refer to the CCS-UC-1 Supplemental Guide (Doc. 7844).
For Additional Information
Compliance and Legal
As of the date of manufac ture, th e product has been tes ted and fo und to com ply wit h speci ficat ions for C E marking.
Federal Communications Commission (FCC) Compliance Statement
This dev ice comp lies wi th par t 15 of the F CC Rules . Operation is s ubjec t to the fo llowin g condit ions: ( 1) This d evice ma y not cause harmf ul inter feren ce and (2) this dev ice must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This e quipm ent has been tes ted and fo und to com ply wit h the lim its for a C lass B digital dev ice, pur suant to p art 15 of the FCC Rules. T hese limits are designed to provide rea sonab le
protec tion against harmfu l inter ference in a resid ential i nstallation. This equipme nt gene rates, uses and can radiate radio fr equen cy energy and, i f not ins talled and used i n accordance wit h the instr uctions, ma y cause harmful interference to radio com munications . However, there is no guarantee t hat interference will not occur in a particula r installatio n. If thi s equipment does cause harmfu l inter ference to radio or television reception, which can be dete rmine d by turning the equipmen t off and on, the user is encouraged to try to correc t the interfe rence by one or more o f the following measures:
Reori ent or rel ocate th e receiving ant enna.
Increase the separation between the equipment and receiver.
Conne ct the equipm ent into an outlet on a circui t different fro m that to which the r eceive r is connected .
Consu lt the de aler or an experienced r adio/ TV technician for help.
Scan or click the QR codes for detailed product information.
CCS- U C-1 W/PS CCS- U C-1 -AV W/ PS CCS-UC-1-AV-PLUS
Industry Canada (IC) Compliance Statement
CAN ICE S-3 (B)/N MB-3(B)
The product warrant y can be found at ww w.crestron.com/warrant y.
The spe cific p atent s that cover Cres tron pro duct s are lis ted at ww w.crestron.com/legal/patents.
Certa in Crestron pro duct s contain open so urce sof tware. For specific information, please visit w ww.crestron.com/opensource.
Crestron, the C restron logo, and Cres tron Mercury a re either trademarks or regis tered t rademarks of Crestron Elect ronic s, Inc . in the Un ited States and/or other countries . HDMI and the HD MI logo are e ither t radem arks or registered tra demarks of HDMI Licensing LLC i n the Uni ted State s and/or oth er count ries. Zoom is either a tra demar k or a registered t radem ark of Zoo m Video Commun icatio ns, Inc. in the U nited States and/or other cou ntries. Oth er trademarks, registered tradem arks, and trad e names m ay be used in this d ocume nt to refer t o eithe r the entities cl aiming the marks and names or th eir product s. Cres tron dis claims any propr ietar y intere st in the marks and names of other s. Cres tron is n ot respo nsibl e for erro rs in ty pogra phy or pho tography
©2018 Crestron Electronics, Inc.
Crestron Electronics, Inc.
15 Volvo Dr ive, Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576
www.crestron.com
Quick Start - Do c. 7843E
Specifications subject to
change without notice.
(20 53074)
12.1 8