NOTE: During the next step, the four SEM (attached washer) screws must be
retained to install the CAGE2. However, the blank plate will not be reused.
4. Refer to the diagram below. Use a #2 Phillips screwdriver to remove
four rear-mounting SEM screws that secure the AV2 blank plate and
remove the plate.
CAGE2 Installation (3 of 11) - Remove Rear-Mounting SEM Screws & AV2 Blank Plate
NOTE: During the next step, the two screws must be retained to install the CAGE2.
However, the two nuts will not be reused.
5. Refer to the diagram below. From inside the AV2, use a 1/4-in hexdriver or wrench to hold the nut of one of the bottom-mounting screws.
From the underside of the AV2, use a #2 Phillips screwdriver to
remove the mounting screw. Repeat for second nut and screw.
8. Refer to the diagram below. Align the PCB jumper to the AV2
processor board connector and slide the CAGE2 assembly towards rear
of AV2. Make sure that PCB jumper is inserted into the AV2 connector
and align the CAGE2 bottom and rear mounting holes.
CAGE2 Installation (7 of 11) - Slide CAGE2 Assembly Rearwards
9. Refer to the diagram below. Install the two bottom-mounting screws
that were removed in step 5 to finger-tight
then, using a #2 Phillips tip
screwdriver tighten the screws an additional 1/8-turn
CAGE2 Installation (8 of 11) - Install Bottom-Mounting Screws
10. Refer to the diagram below. Re-install the the four rear-mounting SEM
(attached washer) screws that were removed in step 4 to finger-tight
then, using a #2 Phillips tip screwdriver tighten the screws an
additional 1/8-turn
CAGE2 Installation (9 of 11) - Re-install Rear-Mounting Screws
.
11. Position cover onto the AV2.
NOTE: The AV2 cover side screws are 0.375 in long and the cover top screws are
0.250 in long. Make sure that the correct screws are re-installed in the cover side and
top, respectively.
12. Refer to the diagram below. Re-install the six cover screws that were
removed from each side of the AV2 in step 2 to finger-tight
then,
using a #2 Phillips tip screwdriver tighten the screws an additional
1/8-turn
CAGE2 Installation (10 of 11) - Re-install Cover Side Screws
.
13. Refer to the diagram on the next page. Re-install the four
that were removed from the top of the AV2 in step 1 to finger-tight
cover screws
then, using a #2 Phillips tip screwdriver tighten the screws an
additional 1/8-turn
CAGE2 Installation (11 of 11) - Re-install Cover Top Screws
14. Refer to the installation and operation guide supplied with the
expansion card for card installation instructions. If more than one plugin expansion card is to be utilized in the AV2, additional face-plate(s)
of the CAGE2 must be removed.
SIMPL Windows Programming
SIMPL (Symbol Intensive Master Programming Language) is an easy-to-use
programming language that is completely integrated and compatible with all
Crestron system hardware. The objects that are used in SIMPL are called symbols.
SIMPL Windows offers drag and drop functionality in a familiar Windows®
environment.
SIMPL Windows is Crestron's software for programming Crestron control systems.
It provides a well-designed graphical environment with a number of workspaces
(i.e., windows) in which a programmer can select, configure, program, test, and
monitor a Crestron control system.
NOTE: Crestron 2-Series control processors require SIMPL Windows version 2.00
or later. The latest software versions can be obtained from the What’s New page
(SIMPL Windows section) or Downloads page (SIMPLWIN Library) of Crestron’s
website (www.crestron.com
). New users are required to register in order to obtain
access to the FTP site.
NOTE: The following table assumes that the reader has knowledge of SIMPL
Windows. If not, refer to the extensive help information provided with the software.
To create a program with an AV2 equipped with an optional CAGE2 card cage, in
the Configuration Manager of SIMPL Windows, refer to the table below for initial
configuration information.
The table below provides corrective action for possible trouble situations. If further
assistance is required, please contact a Crestron customer service representative.
CAGE2 Troubleshooting
TROUBLE
Expansion card(s)
do not function
properly.
*
The appropriate document can be obtained from the Products page (PRODUCT
MANUALS section, hardware section) or Downloads page (MANUAL Library) of
Crestron’s website (www.crestron.com). New users are required to register in order to
obtain access to the FTP site.
Follow installation procedures in this
guide.
Replace PCB interconnect jumper.
Inspect connector pins. If damaged,
contact Crestron customer service.
Refer to "Troubleshooting" section of
the Operations & Installation Guide
supplied with the expansion card. *
Further Inquiries
If you cannot locate specific information or have questions after reviewing this
guide, please take advantage of Crestron's award winning customer service team by
calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876].
For assistance in your local time zone, refer to the Crestron website
(www.crestron.com
) for a listing of Crestron worldwide offices.
You can also log onto the online help section of the Crestron website
(www.crestron.com
) to ask questions about Crestron products. First-time users will
need to establish a user account to fully benefit from all available features.
Future Updates
As Crestron adds improvements to the CAGE2, additional information may be made
available as manual updates. These updates are solely electronic and serve as
intermediary supplements prior to the release of a complete technical documentation
revision.
Check the Crestron website (www.crestron.com
availability and its relevance. Updates are available from the Download | Product
Manuals section and are identified as an “Addendum” in the Download column.
1. No merchandise may be returned for credit, exchange, or service without prior
authorization from CRESTRON. To obtain warranty service for CRESTRON
products, contact the factory and request an RMA (Return Merchandise
Authorization) number. Enclose a note specifying the nature of the problem, name
and phone number of contact person, RMA number, and return address.
2. Products may be returned for credit, exchange, or service with a CRESTRON Return
Merchandise Authorization (RMA) number. Authorized returns must be shipped
freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J., or its authorized
subsidiaries, with RMA number clearly marked on the outside of all cartons.
Shipments arriving freight collect or without an RMA number shall be subject to
refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a
15% restocking fee, plus shipping costs, on any products returned with an RMA.
3. Return freight charges following repair of items under warranty shall be paid by
CRESTRON, shipping by standard ground carrier. In the event repairs are found to
be non-warranty, return freight costs shall be paid by the purchaser.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in
materials and workmanship under normal use for a period of three (3) years from the date of
purchase from CRESTRON, with the following exceptions: disk drives and any other moving or
rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1)
year; touchscreen display and overlay components are covered for 90 days; batteries and
incandescent lamps are not covered.
This warranty extends to products purchased directly from CRESTRON or an authorized
CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the
dealer's warranty, if any.
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in
any application other than that for which it was intended, or if it has been subjected to misuse,
accidental damage, modification, or improper installation procedures. Furthermore, this warranty
does not cover any product that has had the serial number altered, defaced, or removed.
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall
CRESTRON be liable for incidental or consequential damages of any kind (property or economic
damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for
any claim made by a third party or made by the purchaser for a third party.
CRESTRON shall, at its option, repair or replace any product found defective, without charge for
parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be
covered only by the unexpired portion of the warranty.
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed
or implied, nor authorizes any other party to offer any warranty, including any implied warranties
of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed
by law are limited to the terms of this limited warranty. This warranty statement supercedes all
previous warranties.
Trademark Information
All brand names, product names, and trademarks are the sole property of their respective owners. Windows is a registered
trademark of Microsoft Corporation. Windows95/98/Me and WindowsNT/2000 are trademarks of Microsoft Corporation.