Crestron Automation Enclosures (CAENIB-Series) are
wall-mounted metal enclosures that house Crestron
Industry Compliance
This product is Listed to applicable UL Standards and
requirements by Underwriters Laboratories Inc.
lighting modules (CLXI-Series), terminal blocks
(CLTI-Series), terminal blocks with integrated load-side
circuit breakers (CLTIBN-Series), and Professional
Automation Computers (PAC2 and PAC2M). Third-party
Functional Summary
(E227280)
products such as phone and alarm systems can be
installed into the enclosure with or without Crestron
Universal Mounting Plates (CAEN-UMP). The CAENIBSeries enclosures are available in a variety of sizes. The
size corresponds to the number of modules and their
arrangement within the enclosure. For example, 7x2 and
4x2 are double-wide enclosures that hold up to 14 and 8
modules, respectively. The others are single-wide and can
hold 2, 4, or 7 modules. Refer to the illustration and table
on this page for an alphanumeric listing of CAENIB
models, overall dimensions, and weight.
Houses Crestron Lighting Modules, Terminal
Blocks, Professional Automation Computer, and
third-party products with or without Crestron
Universal Mounting Plates
• Flush or surface mounted installation
• Ventilated cover for convection cooling of
modules
• Conveniently located electrical knockouts for
both high voltage and Class 2 wiring
• 16 gauge hot dipped galvanized steel
NOTE: The PAC2 occupies two module spaces in a
double-wide enclosure and one module space in a singlewide.
NOTE: Four keyholes are located within the enclosure
and should be used if surface mounting.
CAENIB Overall Dimensions (Front and Side Views)
W1
W2
W3
H1H3
W3
W4
W5
Crestron Electronics, Inc. Installation Guide – DOC. 6562
15 Volvo Drive Rockleigh, NJ 07647 (2017317)
Tel: 888.CRESTRON 02.07
Fax: 201.767.7576 Specifications subject to
www.crestron.com change without notice.
W3
W6
H2
D1
Specifications
DIMENSIONS7x2 7x1 4x2 4x1 2x1
H1
(mm (in))
H2
(mm (in))
H3
(mm (in))
W1
(mm (in))
W2
(mm (in))
W3
(mm (in))
W4
(mm (in))
W51
(mm (in))
W6
(mm (in))
D1
(mm (in))
Cover
Thickness
Cover Height
(mm (in))
Cover Width
(mm (in))
Included Cover
Plates2
Weight (empty)
(kg (lb))
Max. Weight
(filled) (kg (lb))
1. The lower keyholes are not symmetrically spaced within singlewide enclosures.
2. Additional cover plates are available from Crestron.
3. Weight (empty) is the weight of an empty enclosure with cover.
1575
(62)
(211/16)
1422
(56)
673
(261/2)
647
(251/2)
(21/2)
520
(201/2)
520
(201/2)
(21/2)
104
(41/8)
(1/16)
1593
(623/4)
692
(271/4)
68
63
63
1
1575
(62)
68
(211/16)
1422
(56)
390
(153/8)
365
(143/8)
44
(13/4)
276
(107/8)
250
(97/8)
69
(23/4)
104
(41/8)
1
(1/16)
1593
(623/4)
409
(161/8)
987
(387/8)
987
(387/8)
68
(211/16)
835
(32
673
(261/2)
647
(251/2)
(21/2)
520
(201/2)
520
(201/2)
(21/2)
104
(41/8)
(1/16)
1006
(395/8)
692
(271/4)
63
63
(21/8)
863
7
/8)
(34)
390
(153/8)
365
(143/8)
(13/4)
276
(107/8)
250
(97/8)
(23/4)
104
(41/8)
1
(1/16)
1006
(395/8)
409
(161/8)
6 3 4 2 1
3
29.5
(65)
90.9
(200)
19.5
(43)
45.5
(100)
20
(44)
45.5
(100)
13.2
(29)
(55)
53
44
69
1
22
596
(231/2)
53
(21/8)
(18
473
5
/8)
390
(153/8)
365
(143/8)
44
(13/4)
276
(107/8)
250
(97/8)
69
(23/4)
104
(41/8)
1
(1/16)
615
(241/4)
409
(161/8)
8.6
(19)
14.1
(31)
Automation Enclosures Crestron CAENIB
Installation
The enclosure must be mounted by a licensed electrician
in accordance with all national and local codes. Refer to
table on first page for the weight of a fully loaded
enclosure.
When choosing components to place in the enclosure,
refer to the table on page 1 to ensure that the maximum
weight capacity is not exceeded. Each module’s product
page on the Crestron website lists the module’s weight.
CLTI and CLTIBN terminal blocks and CLXI modules
must be mounted using screw holes shown in the
“Mounting Detail” diagrams. Note that the CLTIBN
terminal blocks include circuit breakers with overload
protection. For applications where an RCCBO (Residual
Current Circuit Breaker with Overload) is needed, you
must replace the corresponding breaker provided with the
RCCBO of your choice. Note that the presence of an
RCCBO requires that the CLXI module be mounted in a
different location to allow for the added size of the new
breaker. For additional information, see the
documentation that ships with the CLTIBN.
CAUTION: These enclosures house equipment that
needs to be air-cooled. Therefore, mount in a wellventilated area. The ambient temperature range should be
0°C to 40°C (32°F to 104°F). The relative humidity
should range from 0% to 90% (non-condensing).
Furthermore, allow adequate clearance in front of the
vented cover for servicing and ventilation.
NOTE: Install modules into the lowest available spaces
and continue toward the top of the enclosure.
NOTE: Enclosures are intended for indoor use only.
NOTE: When flush mounting, 16mm (5/8”) drywall is
preferred.
high voltage wiring are shown along the top and side(s) of
the unit. The lower area is reserved for Class 2 wiring.
Tighten all CLTI- and CLTIBN-Series terminal block
screws and grounding terminal block screws to the torque
specified in the Torque Data table below.
CAUTION: Failure to properly tighten the screws may
result in poor electrical connection and overheating of the
terminals.
Torque Data
CLTI/CLTIBN
Terminal
Blocks
Wire Range
(mm2 (AWG))
Torque
(N-m (lb-in))
0.34 – 6.0
(22 – 10)
1.02
(9)
Key – Typical Products in a CAENIB Enclosure
CLXI-SERIES
MODULE
TERMINAL BLOCKS
CLTI-SERIES (L) & CLTIBN (R)
Mounting Details - Single-Wide CAENIB
MOUNT
CLTIBN
TO THESE
HOLES
MOUNT
CLTI
TO THESE
HOLES
Grounding Terminal
Blocks
2.5 – 6.0
(14 – 10)
3.95
(35)
PROFESSIONAL AUTOMATION
COMPUTERS
PAC2 (L) & PAC2M (R)
10.0
(8)
4.52
(40)
16 – 25
(6 – 4)
5.08
(45)
GROUNDING
TERMINAL
BLOCKS
Wiring
CAUTION: All power feeds must be protected by
appropriate branch circuit breakers as required by national
and local code (supplied by others).
NOTE: Use copper conductors only – rated 60°C
NOTE: All wiring must be installed in accordance with
all local and national electrical codes.
NOTE: Two snap bushings are supplied. If required,
insert into knockouts at the bottom of the enclosure to
prevent damage to low voltage wiring.
High voltage and Class 2 field wires must be kept
separate. Refer to the following illustrations showing
single-wide and double-wide wiring details. Areas for
MOUNT CLTI AND CLTIBN TERMINAL BLOCKS AND CLXI MODULES TO
THE HOLES SHOWN ABOVE
MOUNT
CLTIBN
TO THESE
HOLES
MOUNT
CLTI
TO THESE
HOLES
MOUNT CLXI
TO THESE HOLES
WHEN USING CLTI OR
CLTIBN
Cover Plates
Prior to installing the ventilated cover, any bay in the
CAENIB that does not contain a CLTIBN terminal block
must be covered using a CAENIB blank cover plate. Each
CAENIB model includes some cover plates for covering
empty bays. Additional cover plates are available for
purchase from Crestron. Refer to the table on page 1 to
see how many cover plates are included with each
CAENIB enclosure. For instructions on installing the
blank cover plate, refer to the latest version of the
CAENIB-BP Installation Guide (Doc. 6563) which is
available for download from the Crestron website
(www.crestron.com/manuals).
If you cannot locate specific information or have
questions after reviewing this guide, please take
advantage of Crestron's award winning customer service
team by calling the Crestron corporate headquarters at
1-888-CRESTRON [1-888-273-7876]. For assistance in
your local time zone, refer to the Crestron website
(
www.crestron.com
offices.
You can also log onto the online help section of the
Crestron website to ask questions about Crestron
products. First-time users will need to establish a user
account to fully benefit from all available features.
) for a listing of Crestron worldwide
Merchandise Returns / Repair Service
1. No merchandise may be returned for credit, exchange or service
without prior authorization from CRESTRON. To obtain
warranty service for CRESTRON products, contact an authorized
CRESTRON dealer. Only authorized CRESTRON dealers may
contact the factory and request an RMA (Return Merchandise
Authorization) number. Enclose a note specifying the nature of
the problem, name and phone number of contact person, RMA
number and return address.
2. Products may be returned for credit, exchange or service with a
CRESTRON Return Merchandise Authorization (RMA) number.
Authorized returns must be shipped freight prepaid to
CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized
subsidiaries, with RMA number clearly marked on the outside of
all cartons. Shipments arriving freight collect or without an RMA
number shall be subject to refusal. CRESTRON reserves the right
in its sole and absolute discretion to charge a 15% restocking fee
plus shipping costs on any products returned with an RMA.
3. Return freight charges following repair of items under warranty
shall be paid by CRESTRON, shipping by standard ground
carrier. In the event repairs are found to be non-warranty, return
freight costs shall be paid by the purchaser.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. warrants its products to be free from
manufacturing defects in materials and workmanship under normal use
for a period of three (3) years from the date of purchase from
CRESTRON, with the following exceptions: disk drives and any other
moving or rotating mechanical parts, pan/tilt heads and power supplies
are covered for a period of one (1) year; touchscreen display and overlay
components are covered for 90 days; batteries and incandescent lamps
are not covered.
This warranty extends to products purchased directly from CRESTRON
or an authorized CRESTRON dealer. Purchasers should inquire of the
dealer regarding the nature and extent of the dealer's warranty, if any.
CRESTRON shall not be liable to honor the terms of this warranty if the
product has been used in any application other than that for which it was
intended or if it has been subjected to misuse, accidental damage,
modification or improper installation procedures. Furthermore, this
warranty does not cover any product that has had the serial number
altered, defaced or removed.
This warranty shall be the sole and exclusive remedy to the original
purchaser. In no event shall CRESTRON be liable for incidental or
consequential damages of any kind (property or economic damages
inclusive) arising from the sale or use of this equipment. CRESTRON is
not liable for any claim made by a third party or made by the purchaser
for a third party.
CRESTRON shall, at its option, repair or replace any product found
defective, without charge for parts or labor. Repaired or replaced
equipment and parts supplied under this warranty shall be covered only
by the unexpired portion of the warranty.
Except as expressly set forth in this warranty, CRESTRON makes no
other warranties, expressed or implied, nor authorizes any other party to
offer any warranty, including any implied warranties of merchantability
or fitness for a particular purpose. Any implied warranties that may be
imposed by law are limited to the terms of this limited warranty. This
warranty statement supersedes all previous warranties.
Trademark Information
All brand names, product names, and trademarks are the sole property of their respective
owners. Windows is a registered trademark of Microsoft Corporation. Windows95/98/Me/XP
and WindowsNT/2000 are trademarks of Microsoft Corporation.