Crestron BB-8X-DSW Pre-Construction Wall Mount Back Box
Pre-Construction Wall Mount
Back Box: BB-8X-DSW
Description
The BB-8X-DSW back box provides a UL®-listed, recess-mounted steel enclosure
for the TPMC-8X-DSW Wall Mount Docking Station. Designed for pre-construction
applications, the BB-8X-DSW permits fastening to the left or right side of a stud in a
framed wall prior to installation of sheet rock. Conduit knockouts are provided on
the top and bottom to accommodate a variety of fittings and a blank cover plate is
included.
The table below lists all parts included with the BB-8X-DSW.
Supplied Hardware for the BB-8X-DSW
DESCRIPTION PART NUMBER QUANTITY
Assembly, Wall Mount, Back Box 4504293 1
Metal, Cover, Front 2017660 1
Screw, #06-32 x 1-1/2”, Pan, Phil 2007254 4
Installation Guide – DOC. 6579A Pre-Construction Wall Mount Back Box: BB-8X-DSW • 1
Pre-Construction Wall Mount Back Box Crestron BB-8X-DSW
The mounted view of the BB-8X-DSW is shown in the following illustration.
2 • Pre-Construction Wall Mount Back Box: BB-8X-DSW Installation Guide – DOC. 6579A
Crestron BB-8X-DSW Pre-Construction Wall Mount Back Box
The dimensions of the BB-8X-DSW are shown in the following illustration.
BB-8X-DSW Dimensional Drawing (Fully Assembled without Cover Plate)
12.29 in
(31.21 cm)
1.25 in
(3.18 cm)
(2.54 cm)
9.32 in
(23.66 cm)
0.10 in
(0.25 cm)
1.00 in
0.63 in
(1.59 cm)
10.79 in
(27.40 cm)
5.08 in
(12.90 cm)
3.06 in
(7.78 cm)
3.25 in
(8.26 cm)
(18.74 cm)
1.64 in
(4.16 cm)
0.38 in
(0.96 cm)
7.38 in
(0.96 cm)
0.84 in
(2.14 cm)
0.38 in
10.93 in
(27.78 cm)
13.79 in
(35.03 cm)
NOTE: Knockout holes are intended for Class 2 wiring only and are ½” and ¾”
diameter.
BB-8X-DSW Dimensional Drawing (Cover Plate)
10.00 in
(25.40 cm)
11.50 in
(29.21 cm)
0.30 in
(0.08 cm)
Installation Guide – DOC. 6579A Pre-Construction Wall Mount Back Box: BB-8X-DSW • 3
Pre-Construction Wall Mount Back Box Crestron BB-8X-DSW
Installation
Assembly
Required Tools:
• #2 Phillips tip screwdriver
The back box mounting enclosure comes fully assembled except for a grounding
screw. To prepare for mounting, complete the following procedure.
1. Remove knockouts as required.
2. Slightly loosen #08-8B self-tapping screw in the back box mounting
enclosure assembly for attaching ground connection.
NOTE: The #08-8B self-tapping screw (2007277) supplied for grounding purposes,
is installed in the rear of the back box mounting enclosure assembly.
Mounting
Required Tools:
• #2 Phillips tip screwdriver or hammer
• Level
NOTE: If your installation is not on wooden studs, be sure to consider the needs of
your particular situation. For example, screw type may vary for steel studs, etc.
To mount the back box, complete the following procedure (refer to illustration on the
following page).
1. Position the back box against the stud so that the extended edge of the
attached mounting plate covers the front edge of the stud. Be sure the side
of the back box is also against the side of the stud.
2. Use the level to verify the back box is horizontal. Leveling must be done
before proceeding.
3. Attach the back box to the left or right side of the stud with standard
drywall screws or nails (not included). If mounting to the left side of a stud,
the back box must be turned over so that the extended edge of the attached
mounting plate is on the right side.
4. Feed cables through the knockout holes.
NOTE: This assembly should use Class 2 wiring only.
4 • Pre-Construction Wall Mount Back Box: BB-8X-DSW Installation Guide – DOC. 6579A
Crestron BB-8X-DSW Pre-Construction Wall Mount Back Box
Mounting the Back Box
FOR DRYWALL SCREW (NOT INCLUDED)
FOR DRYWALL NAIL (NOT INCLUDED)
FOR DRYWALL SCREWS OR NAILS
TO MOUNT TO STUD (NOT INCLUDED)
ENCLOSURE ASSEMBLY (4504293)
FOR TPMC-8X-DSW
#08-8B x ¼" SELF TAPPING SCREW
(2007277) FOR GROUNDING
FOR DRYWALL NAIL (NOT INCLUDED)
FOR DRYWALL SCREW (NOT INCLUDED)
NOTE: BE SURE THE ASSEMBLY IS LEVEL WHEN MOUNTED
Installation Guide – DOC. 6579A Pre-Construction Wall Mount Back Box: BB-8X-DSW • 5
Pre-Construction Wall Mount Back Box Crestron BB-8X-DSW
Mounted View with Cover Plate (Mounting Example Prior to Drywall Installation)
SCREWS (4) #06-32 x 1-½"
PAN HEAD (2007254)
NOTE: BACK BOX IS TO BE COVERED WITH
DRYWALL AND THEN THE CUTOUT MADE
AROUND THE INSIDE OF THE OPENING.
BE SURE TO LEAVE THE FOUR TAPPED HOLES
ON THE FRONT OF THE BOX EXPOSED TO
COVER PLATE (2017660)
TO COVER CUTOUT IN DRYWALL
BEFORE TPMC-8X-DSW IS INSTALLED
(MAY BE REQUIRED BY LOCAL BUILDING CODES)
ACCEPT THE TPMC-8X-DSW MOUNTING SCREWS.
5. Refer to illustration on the following page for exact cutout dimensions.
Position the opening to expose the #06-32 tapped hole in each corner.
6 • Pre-Construction Wall Mount Back Box: BB-8X-DSW Installation Guide – DOC. 6579A
Crestron BB-8X-DSW Pre-Construction Wall Mount Back Box
Dimensions for Drywall Cutout
11.19 in
(28.34 cm)
3/16 in
(4.76 cm)
(DRILL SIZE #Q)
TYP (4X)
0.10 in
(0.25 cm)
7.38 in
(18.74 cm)
1.19 in
(3.02 cm)
1.12 in
(2.84 cm)
10.99 in
(27.91 cm)
9.38 in
(23.81 cm)
9.70 in
(24.63 cm)
0.17 in
(0.41 cm)
CAUTION: Allow an air gap of at least 12 inches (30.48 cm) in the wall cavity
above and below the touchpanel for heat dissipation.
NOTE: The TPMC-8X-DSW may be attached to the BB-8X-DSW using the four
included #06-32 1 ½” screws (two at each side). Refer to the illustration above for
drill bit size and screw hole locations.
6. Complete the installation by either installing the TPMC-8X-DSW and
touchpanel, leaving the hole open (if permitted by local building codes) or
installing the supplied cover plate with the included #06-32 x 1 ½” screws,
as shown in the illustration on the previous page.
If the TPMC-8X-DSW and touchpanel are to be installed, refer to the latest revision
of the TPMC-8X-DSW Installation Guide (Doc. 6588) for installation instructions.
The document is available from the Crestron website
(http://www.crestron/com/manuals
). Refer also to the comprehensive illustration on
the following page.
Installation Guide – DOC. 6579A Pre-Construction Wall Mount Back Box: BB-8X-DSW • 7
Pre-Construction Wall Mount Back Box Crestron BB-8X-DSW
Touchpanel Mounting Using BB-8X-DSW – Exploded View
BB-8X-DSW
DRYWALL
TPMC-8X-DSW
(bezel removed)
TPMC-8X-DSW
MOUNTING SCREWS
(4) #06-32 x 1-1/2"
(2 ON EACH SIDE)
(bezel)
Other Mounting Option Accessories
If too much of the mounting plate is exposed after the drywall is cut, you may need
to patch the area. Crestron provides the following accessories:
• TMK-8X-DSW (Doc. 6582) – for smaller repairs and to provide a smooth
edge at the opening. This option provides a finished appearance and is
preferred when wallpaper is hung.
• MMK-8X-DSW (Doc. 6581) – for larger repairs and to fill in larger
irregularities around the opening (requires plastering)
The manuals for the TMK-8X-DSW and MMK-8X-DSW are available from the
Crestron website.
8 • Pre-Construction Wall Mount Back Box: BB-8X-DSW Installation Guide – DOC. 6579A
Crestron BB-8X-DSW Pre-Construction Wall Mount Back Box
Contact Information and Updates
Further Inquiries
If you cannot locate specific information or have questions after reviewing this
guide, please take advantage of Crestron's award winning customer service team by
calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876].
For assistance in your local time zone, refer to the Crestron website
(http://www.crestron.com/offices
You can also log onto the online help section of the Crestron website
(http://www.crestron.com/onlinehelp
First-time users will need to establish a user account to fully benefit from all
available features.
This product is Listed to applicable UL Standards and requirements by Underwriters
Laboratories Inc.
As of the date of manufacture, the BB-8X-DSW has been tested and found to comply
with specifications for CE marking.
) for a listing of Crestron worldwide offices.
) to ask questions about Crestron products.
(E227280)
Future Updates
As Crestron adds improvements to the BB-8X-DSW, additional information may be
made available as manual updates. These updates are solely electronic and serve as
intermediary supplements prior to the release of a complete technical documentation
revision.
Check the Crestron website periodically for manual update availability and its
relevance. Updates are identified as an “Addendum” in the Download column.
Installation Guide – DOC. 6579A Pre-Construction Wall Mount Back Box: BB-8X-DSW • 9
Pre-Construction Wall Mount Back Box Crestron BB-8X-DSW
Return and Warranty Policies
Merchandise Returns / Repair Service
1. No merchandise may be returned for credit, exchange or service without prior authorization
from CRESTRON. To obtain warranty service for CRESTRON products, contact an
authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory
and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying
the nature of the problem, name and phone number of contact person, RMA number and
return address.
2. Products may be returned for credit, exchange or service with a CRESTRON Return
Merchandise Authorization (RMA) number. Authorized returns must be shipped freight
prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with
RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect
or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its
sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any
products returned with an RMA.
3. Return freight charges following repair of items under warranty shall be paid by CRESTRON,
shipping by standard ground carrier. In the event repairs are found to be non-warranty, return
freight costs shall be paid by the purchaser.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials
and workmanship under normal use for a period of three (3) years from the date of purchase from
CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical
parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and
overlay components are covered for 90 days; batteries and incandescent lamps are not covered.
This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON
dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if
any.
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any
application other than that for which it was intended or if it has been subjected to misuse, accidental
damage, modification or improper installation procedures. Furthermore, this warranty does not cover any
product that has had the serial number altered, defaced or removed.
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall
CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages
inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a
third party or made by the purchaser for a third party.
CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or
labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the
unexpired portion of the warranty.
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or
implied, nor authorizes any other party to offer any warranty, including any implied warranties of
merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are
limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties.
Trademark Information
All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered trademark
of Microsoft Corporation. Windows95/98/Me/XP/Vista and WindowsNT/2000 are trademarks of Microsoft Corporation.
10 • Pre-Construction Wall Mount Back Box: BB-8X-DSW Installation Guide – DOC. 6579A
Crestron BB-8X-DSW Pre-Construction Wall Mount Back Box
This page is intentionally left blank.
Installation Guide – DOC. 6579A Pre-Construction Wall Mount Back Box: BB-8X-DSW • 11
Crestron Electronics, Inc. Installation Guide – DOC. 6579A
15 Volvo Drive Rockleigh, NJ 07647 (2017893)
Tel: 888.CRESTRON 04.07
Fax: 201.767.7576 Specifications subject to
www.crestron.com change without notice.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.