Cres Cor H-339225, H339SS1814CBE Service Manual

Insulated
Hand-lift Cabinets
FL-0520-BE
5925 Heisley Road • Mentor, OH 44060-1833
Rev. 8 (5/13) Page 1 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED HAND-LIFT CABINETS
MODEL H-339225 and H339SS1814CBE
ELECTRICAL SPECIFICATIONS:
MODELS: Volts Watts Amps Hertz Phase NEMA
H-339225-01 / HOT CABINET TOP 120 900 7.5 60 1 5-15
H-339225-02 / PROOFER BOTTOM 120 900 7.5 60 1 5-15
H-339SS1814CBE / HOT CABINET ONLY 120 900 7.5 60 1 5-15
HOW TO INSTALL UNIT: (Figure 1)
See FL-2211-BE (enclosed) for “Stacking Instructions”.
1. Plug cord into receptacle in back of the unit.
2. Turn plug clockwise to lock.
3. Plug other end into 15-amp wall outlet.
4. Place cabinet in a well ventilated area.
5. If no casters are provided, the base must be sealed
to the counter or oor with grout or caulk to maintain sanitation certication.
6. Push the switch on, turn the thermostat to No. 10 and run the unit for one hour.
NOTE: DO NOT PUT IN FOOD! This step is to
burn off manufacturing oils and excessive adhesive.
THERMOSTAT
COVER
SWITCH
THERMOMETER
FIG. 1
6. Let the cabinet cool and wipe inside clean with
detergent and hot water before use.
HOW TO OPERATE UNIT: (Figure 2)
1. Push switch “ON”. Yellow light will come on.
2. Preheat cabinet for 45 minutes; the cabinet temperature is factory preset.
4. Put food into cabinet.
To Turn Off Unit:
Push switch “OFF”. The yellow light will go off.
NOTE: The digital thermometer will ash if cabinet
temperature is below 140°F/60°C or above 250°F/60°C. Call the factory if you need different settings.
FIG. 2
Insulated
WARNING
Hand-lift Cabinets
FL-0520-BE
Rev. 8 (5/13) Page 2 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED HAND-LIFT CABINETS
MODEL H-339225 and H339SS1814CBE
BEFORE CLEANING CABINET:
1. Remove Power Cord from cabinet.
2. Do NOT hose cabinet with water.
3. Do NOT get water on controls.
4. Do NOT use abrasives or harsh chemicals.
HOW TO CLEAN UNIT:
SOIL CLEANER METHOD
DIRT
CABINET
FINGERPRINTS,
GREASE OIL
5925 Heisley Road • Mentor, OH 44060-1833
Hints:
1. Wipe up spills as soon as possible.
2. Clean cabinet regularly to avoid heavy dirt build-up.
3. Make a test spot with cleaner.
4. Follow manufacturer’s directions on cleaner.
5. Do not mix cleaners
6. Avoid drips and splashes.
Mild detergent* and hot water, or mild abrasive cleaner.
Steam (no strong alkaline additive)
Detergent* and hot water.
Chemical oven cleaner.**
Mild abrasive cleaner. Oily or waxy cleaner.
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
1. Rinse after steam cleaning.
2. Wipe dry.
1. Wipe with soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry. Follow oven cleaner manufacturer’s
directions.
Apply with soft, clean cloth.
WATER SPOTS Mild abrasive cleaner. Wipe with damp cloth.
* Mild detergents include soaps and non-abrasive cleaners
**Be sure your cleaner is good for stainless steel for use on cabinet body;
and for aluminum, for use on the rack insert (pan slides)
HOW TO ADJUST THE DOOR LATCH:
1. For vertical adjustment (Up and down movement):
a. Loosen (2) screws located in magnetic
strike on cabinet.
b. Move strike up or down for alignment
to magnet on latch.
c. Tighten screws to secure
2. For horizontal adjustment (Greater or lesser magnetic draw):
a. Loosen four (4) screws in latch on door. b. Move latch forward or backward to
adjust magnetic draw.
c. Tighten screws to secure.