Cres Cor H-339214 User Manual

5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED HAND-LIFT CABINET; MODEL H-339214
ELECTRICAL SPECIFICATIONS:
MODEL Volts Watts Amps Hertz Phase NEMA
H-339214 120 900 7.5 60 1 5-15
SWITCH LIGHT
“ON-OFF”
THERMOSTAT
THERMOMETER
Insulated
Hand-lift Cabinet
Rev. 3 (10/08) Page 1 of 4
FL-0520-12
DOOR
VENT
Plug cord into 20-amp wall outlet.1. Place cabinet in a well ventilated area.2. Push the switch on, turn the thermostat to No. 10 3. and run the unit for one hour.
NOTE: DO NOT PUT IN FOOD! This step is to burn off manufacturing oils and excessive adhesive.
4. Let the cabinet cool and wipe inside clean with detergent and hot water before use.
FIGURE 1
HOW TO OPERATE UNIT: (Figure 1)
Push switch “ON”. Yellow light will come on.1. Turn thermostat to the temperature you need.2.
NOTE: No. 7½ setting will give you about 180° F.
Proper food holding temperature is 140° F or higher.
3. Preheat cabinet for 45 minutes
4. Put food into cabinet.
5. Turn the wing nut on the door vent to open the vent when less humidity is needed.
To Turn Off Unit:
Push switch “OFF”. The yellow light will go off. NOTE: Thermometer gives the inside cabinet
temperature.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Insulated
Hand-lift Cabinet
Rev. 3 (10/08) Page 2 of 4
FL-0520-12
OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED HAND-LIFT CABINET; MODEL H-339214
WARNING
5925 Heisley Road • Mentor, OH 44060-1833
BEFORE CLEANING CABINET:
1. Unplug power cord from wall.
2. Do NOT hose cabinet with water.
3. Do NOT get water on controls.
4. Do NOT use abrasives or harsh chemicals.
HOW TO CLEAN UNIT:
SOIL CLEANER METHOD
ROUTINE CLEANING
CABINET
STUBBORN SPOTS
Inside and Outside
(Stainless Steel)
AND STAINS BURNT-ON FOODS
OR GREASE HARD WATER
SPOTS and SCALE
* Mild detergents include soaps and non-abrasive cleaners
Hints:
Wipe up spills as soon as possible. 1. Clean cabinet regularly to avoid heavy dirt build-up.2. Make a test spot with cleaner.3. Follow manufacturer’s directions on cleaner.4. Do not mix cleaners5. Avoid drips and splashes.6.
Soap, Ammonia, or mild* detergent and water
Mild abrasive made for stainless steel
Chemical oven cleaner for stainless steel
Vinegar
1. Sponge on with cloth.
2. Rinse with water.
3. Wipe dry.
1. Apply with damp sponge or cloth.
2. Rub lightly. Follow oven cleaner
manufacturer’s directions.
1. Swab or wipe with cloth.
2. Rinse and dry.
HOW TO ADJUST THE DOOR LATCH:
1. For vertical adjustment (Up and down movement):
a. Loosen (2) screws located in magnetic
strike on cabinet.
b. Move strike up or down for alignment
to magnet on latch.
c. Tighten screws to secure
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
2. For horizontal adjustment (Greater or lesser magnetic draw):
a. Loosen four (4) screws in latch on door. b. Move latch forward or backward to
adjust magnetic draw.
c. Tighten screws to secure.
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED HAND-LIFT CABINET; MODEL H-339214
HOW TO REVERSE DOOR HARDWARE FOR OPPOSITE HAND (Refer to Fig. 3 [hinge]):
Pop off hinge covers with screwdriver.1. Remove screws from hinges to cabinet; remove door 2. and unscrew latch strike from cabinet. Remove hinges, latch and all remaining screws from 3. the right and left side of door. Keep all screws. Re-mount hinges and latch in the same hole pattern on 4. the opposite sides of the door. Plug all extra holes with screws. Remove all screws from the front sides of cabinet (not 5. the top and bottom).
Hold door up to cabinet and screw hinges to the 6. cabinet.
Open door and re-mount the latch strike to cabinet. 7. Plug all extra holes with screws and snap on the hinge 8. covers.
DOOR
TOP
Insulated
Hand-lift Cabinet
Rev. 3 (10/08) Page 3 of 4
CABINET
BODY
FL-0520-12
HINGE COVER
FIGURE 2
REPLACEMENT PARTS
Cord Set.................................... H339214-08
Switch....................................... 0808-113
Heater Kit..................................0811-066-K
Thermostat Kit..........................0848-062-K
T erminal Block..........................0852-091
Thermometer.............................5238-030
Door Latch Kit..........................1006-122-01-K
Strike Kit...................................1006-122-02-K
Hinge Kit...................................0519-074-K
Gasket Kit.................................0861-077
Casters.......................................0569-306
Casters w/Brake........................0569-306-B
Door Replacement Kit..............5508-084-SS
Rack Insert................................1170-122
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
TROUBLE-SHOOTING CHART
FAILURE POSSIBLE CAUSE/CHECK
1. Unit does not heat: 1a. Thermostat turned up. 1b. Switch is “ON”.
1c. Cord is plugged into outlet. 1d. Circuit breaker/fuse for
wall outlet
2. Unit will not turn off: 2a. Thermostat turned down. 2b. Switch is “OFF”
If cause is none of the above, refer to our list of authorized service agencies, FL-1400.
Instructions for replacing parts are included in replacement parts kits.
Insulated
Hand-lift Cabinet
Rev. 3 (10/08) Page 4 of 4
FL-0520-12
OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED HAND-LIFT CABINET; MODEL H-339214
5925 Heisley Road • Mentor, OH 44060-1833
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com