Cres Cor H137WSUA12, H137WSUA12208, H138WS Series, H138WS1834, H138WS1834208 Operating And Maintenance Instructions Manual

...
Page 1
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WS/H138WS Series Proof/Hot Cabinets
ELECTRICAL SPECIFICATIONS:
H137WSUA12 H138WS1834
120 2000 16.6 60 1 5-20P
Proof/Hot Cabinets
FL-2225
Rev. 8 (10/08) Page 1 of 4
H137WSUA12208 H138WS1834208
H137WSUA12240 H138WS1834240
208 2000 9.6 60 1 6-15P
240 2000 8.6 60 1 6-15P
All are designed for AC service. The above model numbers may be followed by “L” or ending with “S”.
2
HOW TO INSTALL UNIT:
1
Place cabinet near warm ovens. 1. DO NOT place cabinet in drafty areas or near ventilating systems.
Plug end into proper wall outlet. 2. Fill water pan. 3.
- Lift off cover.
- Fill with 3-1/2 qts.(3.3 liters) of clean, hot water. Replace cover.
Use of treated or soft
CAUTION
water may be required
6
5
7
ON
OFF
POWER
( I )
( 0 )
4
3
8
2
HUMIDITY
9
10
OFF
1
R
CONTROL PANEL PARTS IDENTIFICATION
1. Switch-Power 4. Thermostat-Air
2. Pilot Light-Power 5. Thermometer
3. Thermostat-Humidity
6
5
7
4
3
8
2
9
1
10
OFF
AIR
43
for proper operation and to maintain warranty .
5
HOW TO PROOF:
Fill water pan (See “How to Install”) 1. Push “POWER” switch to “ON.” The yellow light 2. will come on. Turn “HUMIDITY” dial to No. 10. 3. Turn “AIR” dial to “OFF.” 4. Preheat for 30 minutes. “ 5. Put fresh or fully thawed dough into cabinet. 6. Turn “HUMIDITY THERMOSTAT” to No. 9. 7.
NOTE: The cabinet temperature will drop temperature
inside cabinet if cold dough is added.
Do NOT put frozen dough into cabinet
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
NOTE: No 9-10 setting will give you a temperature
of 95°F/35°C, and 90-95% humidity. Experiment with different “HUMIDITY” and “AIR” settings to get the exact temperature and humidity you need. The thermometer display will fl ash when cabinet is below 140°F/60°C.
NOTE: Check water level in water pan if you are
proofi ng longer than 90 minutes. Fill with clean, hot water.
Page 2
Proof/Hot Cabinets
Rev. 8 (10/08) Page 2 of 4
FL-2225
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WS/H138WS Series Proof/Hot Cabinets
HOW TO HOLD
Push “POWER” switch to “ON.” The yellow light 1. will come on. Turn “AIR” dial to temperature needed.2.
NOTE: No. 8 is about 175°F/79°C No. 6 is about 145°F/63°C No. 4 is about 115°F/46°C
Proper food holding temperature is 140°F (60°C) or higher. The thermometer display ashes when
the center of the cabinet is below 140°F/60°C or above 250°F/121°C. Call the factory if you need different settings.
3. Turn the “HUMIDITY” dial to “OFF”.
4. Preheat cabinet for 30 minutes.
5. Put food into cabinet.
HOW TO HOLD WITH HUMIDITY:
Fill water pan (see “How to Install”).1. Push “POWER” switch to “ON”. The yellow 2. light will come on. Turn “AIR” dial to No. 10.3. Preheat cabinet for 30 minutes.4. Turn “AIR” and “HUMIDITY” dial to No. 10.5. Preheat cabinet for an additional 15 minutes.6. Turn “AIR” dial to temperature needed.7.
NOTE: No. 8 is about 185°F/85°C No. 6 is about 160°F/71°C No. 4 is about 130°F/54°C
Proper food holding temperature is 140°F (60°C) or higher. The thermometer display ashes when
the center of the cabinet is below 140°F/60°C or above 250°F/121°C. Call the factory if you need different settings.
8. Turn the “HUMIDITY” dial to desired humidity. At 175°F/80°C, No. 9 setting on the “Humidity” dial is about 25% relative humidity.
NOTE: Higher numbers give higher humidity at the
same temperature.
5925 Heisley Road • Mentor, OH 44060-1833
NOTES: Experiment with different settings to get the
exact temperature and humidity required.
Check water level in water pan if holding
more than 2-1/2 hours.
Fill pan with hot water
HOW TO TURN UNIT “OFF”:
Turn “POWER” switch to “OFF”.
MAINTENANCE: HOT UNIT REMOVAL INSTRUCTIONS:
Unplug power cord from wall outlet.1. Pull entire unit out the front of the cabinet. You 2. may have to remove a screw in the back of the cabinet above the cord.
WARNING
BEFORE CLEANING THE CABINET:
Allow cabinet to cool.1. Remove Hot Unit from cabinet.2. Do NOT use abrasives or harsh chemicals.3.
Cleaning Notes:
Wipe up spills as soon as possible.1. Clean cabinet regularly to avoid heavy dirt build-up.2. Make a test spot with cleaner.3. Follow manufacturer’s directions on cleaner. 4. Do not mix cleaners.5. Avoid drips and splashes.6. Empty water pan at least once a week.7. Leave doors open to fully dry the cabinet.8.
DELIME OR DESCALE RESERVOIR PARTS AS
CAUTION
WARRANTY COVERAGE MAY BE AFFECTED WITHOUT PROPER CLEANING.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
REQUIRED TO PREVENT DAMAGING BUILD-UP.
Page 3
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WS/H138WS Series Proof/Hot Cabinets
HOW TO CLEAN UNIT:
Soil Cleaner Method
Mild detergent* and hot water, or
Dirt
CABINET
Stainless Steel
Fingerprints, Grease and Oil
Water Spots
*Mild detergents include soaps and non-abrasive cleaners.
mild abrasive cleaner.
Steam (No strong alkaline additive) Chemical oven cleaner for cabinet
material Mild abrasive cleaner; oily or waxy
cleaner Mild abrasive cleaner.
Oily or waxy cleaner.
Proof/Hot Cabinets
Rev. 8 (10/08) Page 3 of 4
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
1. Rinse after steam cleaning.
2. Wipe dry. Follow oven cleaner manufacturer’s
directions Apply with clean, soft cloth. Wipe with
damp cloth. Apply with soft, clean cloth.
Wipe with damp cloth.
FL-2225
TROUBLE-SHOOTING CHART:
FAILURE POSSIBLE CAUSE
1a. Circuit breaker/fuse to wall outlet blown.
1. Indicator lights do NOT light.
2a. Cord unplugged from wall outlet or cabinet. 3a. Switch is “OFF.”
2. Unit does not heat
3. Unit gets too hot or won’t shut off
4. Humidity is low.
2a. Thermostats set too low or are off. 2b. Switch is “OFF.”
3a. Defective electrical parts.
3b. UNPLUG UNIT FROM WALL OUTLET
4a. Water in pan may be low 4b. Thermostat set too low
5. Blower does not work or makes noise. 5a. Defective Blower
NOTE: Digital thermometer will fl ash if cabinet temperature is below 140°F or above 250°F.
Call the Factory if you need different settings.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 4
Proof/Hot Cabinets
FL-2225
Rev. 8 (10/08) Page 4 of 4
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WS/H138WS Series Proof/Hot Cabinets
REPLACEMENT PARTS:
DESCRIPTION Qty. 120 VOLT 208 VOLT 240 VOLT
Proof/Hot Unit (Stainless St., 23.5” W) 1 0747-061 0747-063 0747-062 Heater (Reservoir) 1 0811-005-K 0811-015-K 0811-251 Pan (Reservoir) 1 1019-002 1019-002 1019-002 Heater (Air) 2 0811-214 0811-215 0811-215 Thermostat Kit 2 0848-062-K 0848-062-K 0848-062-K Power Cord 1 0810-093 0810-039 0810-039 Pilot Light (Power) 1 0766-094 0766-095 0766-095 Switch (Power) 1 0808-116 0808-116 0808-116 Blower Kit 1 0769-180-K 0769-182-K 0769-182-K Relay 1 0857-100 0857-102 0857-102 Thermometer Kit (Digital °F) 1 5238-034-K 5238-034-K 5238-034-K Transformer, 110-220V only 1 0759-159 0759-159 0759-159 Thermometer Kit (Digital °C) 1 5238-034-K1 5238-034-K1 5238-034-K1
FOR 208V/240V
TRANSFORMER
110V/220V
THERMOSTAT
WATER
18
WATER
HEATER
(H1)
50
52
50
384
2 1
51
51
5
18
FOR 120V
TRANSFORMER
110V/220V
16
A
B
12
H1
15
4 3 21
8
10
14
H2
13
11
1
4
7
17
51
50
5
AIR HEATERS
(H2 & H3)
RELAY
TERMINAL BLOCK
4
THERMOSTAT AIR
H3
5
A
2
1
5
3
POWER SWITCH
BLOWER
MOTOR
BM
6
6
SENSOR
DIP SWITCH (SW1)
SETTINGS
21 3 1 23
OFF
OFF
SENSOR
6-15P PLUG 240V, 15A
TERMINAL
BLOCK
GG
B
5-20P PLUG 120V, 20A
W
B
W
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Loading...