Cres Cor H137WSUA9C, H137WSUA5C, H137WSUA6C, H138WS185C, H138WS1834C Operators Manual

...
Page 1
Insulated
Hot Cabinets
FL-2253
5925 Heisley Road • Mentor, OH 44060-1833
Rev. 15 (6/08)) Page 1 of 6
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WSUA...C & H137WS18...C Series
Humidity Holding Hot Cabinet
ELECTRICAL SPECIFICATIONS:
Model No. Volts Watts Amps Hertz Phase NEMA
H137WSUA12C H137WSUA9C
H137WSUA5C
H137WSUA6C H138WS185C H138WS1834C H138WS1816C
H137WSUA12C208 H137WSUA9C208 H137WSUA5C208 H137WSUA6C208 H138WS185C208 H138WS1834C208 H138WS1816C208
H137WSUA12C240 H137WUA9C240 H137WSUA5C240 H137WSUA6C240 H138WS185C240 H138WS1834C240 H138WS1816C240
120 2000 16.7 60 1 5-20P
208 2000 9.6 60 1 6-15P
240 2000 8.3 60 1 6-15P
NOTE: The above model numbers are basic models. They may be followed by letters: M, L, D or ending with S and/or Z.
HOW TO INSTALL UNIT:
Place cabinet on level fl oor.1. Plug cord end into proper wall outlet.2.
Air is VERY HOT when door is opened.
Fill water pan with 4 gallons (15 liters) of water. 3.
HOW TO PROOF:
Use of treated or soft water may be required for proper operation and to maintain warranty.
4. Place the cabinet in a well-ventilated area.
5. Push the switch to “On”, turn the “Air” thermostat to No. 9 and run the unit for one hour.
NOTE: DO NOT PUT FOOD IN CABINET! This
step is to burn off manufacturing oils and
NOTE: Do NOT put in frozen dough. NOTE: The optional digital thermometer display
excess adhesive.
6. Let the cabinet cool and wipe inside clean with detergent and hot water before fi rst use.
WARNING
Fill water pan with 1. HOT water. Turn power switch to “ON”. 2. Turn “AIR” thermostat to “PROOF” (No. 1).3. Turn “HUMIDITY” thermostat to No. 3½.4. Preheat for ½ hour (30 minutes).5. Put fresh or 6. fully thawed dough into cabinet.
ashes when temperature in center of cabinet is below 140°F/60°C or above 250°F/121°C. Call the factory if you need different settings.
Page 2
Insulated
Hot Cabinets
FL-2253
Rev. 15 (6/08 Page 2 of 6
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WSUA...C & H137WS18...C Series
HOW TO HOLD:
No water is needed in pan.
Push power switch to “ON.” Yellow light will 1. come on. Turn “AIR” thermostat to No. 9.2. Preheat cabinet for 30 minutes.3. Turn “AIR” thermostat to desired temperature. 4.
(See thermostat settings below.)
Put product into cabinet.5.
5925 Heisley Road • Mentor, OH 44060-1833
Humidity Holding Hot Cabinet
HOW TO HOLD WITH HUMIDITY:
Fill water pan with HOT water.1. Push power switch to “ON.”2. Turn the “AIR” Thermostat to No. 9.3. Turn the “HUMIDITY” thermostat to No. 9.4. Preheat for 30 minutes.5. Turn “AIR” thermostat to desired temperature. 6.
(See thermostat settings below.)
Put product into cabinet.7.
NOTES: 180°F/82°C is approximately No. 8. Proper food holding temperature is 140°F/60°C or higher.
WARNING
Air is VERY HOT when door is opened.
SOME TYPICAL THERMOSTAT SETTINGS:
THERMOSTAT SETTINGS RESULT
Air Humidity Cab. Temp. Humidity
150° F Off 150° F N/A
Med Hold Off 175° F N/A High Hold Off 205° F N/A Maximum Off 220° F N/A
Proof 100° F 98%
Low Low 115° F 98% Low Med 150° F 95%
Low High 150° F 95% Low Hold Low 160° F 30% Low Hold Med 160° F 50% Low Hold High 160° F 95% Med Hold Low 170° F 15% Med Hold Med 170° F 35% Med Hold High 170° F 85% Med Hold Max 170° F 90%
High Hold Low 205° F 7% High Hold Med 205° F 15% High Hold High 205° F 40% Maximum Maximum 220° F 30%
Note: These settings are based on laboratory conditions and may differ from conditions at point of use. Experiment
with the settings to determine what is best for your application.
Page 3
Insulated
Hot Cabinets
FL-2253
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WSUA...C & H137WS18...C Series
Humidity Holding Hot Cabinet
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE
PERSONNEL ONLY
HOW TO TURN UNIT OFF:
Push switch to “OFF” Position.
MAINTENANCE: WATER PAN
Drain, wipe and fi ll water pan daily. (Clear vinyl drain hose is provided.)
Push hose onto drain nozzle under the base.1. Turn knob to open the drain.2.
MAINTENANCE: CABINET
Wipe the inside of cabinet after daily use.1. Leave doors slightly open to fully dry interior2. .
Rev. 15 (6/08)) Page 3 of 6
Delime or descale water pan parts as required, to prevent damaging build­up. WARRANTY COVERAGE MAY BE AFFECTED WITHOUT PROPER CLEANING.
WARNING
BEFORE CLEANING CABINET:
Remove Power Cord from cabinet.1. Do NOT hose cabinet with water.2. Do NOT get water on controls.3. Do NOT use abrasives or harsh chemicals.4.
Cleaning hints:
Wipe up spills as soon as possible.1. Clean cabinet regularly to avoid heavy dirt build-up.2. Make a test spot with cleaner.3. Follow manufacturer’s directions on cleaner.4. Do not mix cleaners.5. Avoid drips and splashes.6.
HOW TO CLEAN THE UNIT:
Soil Cleaner Method
ROUTINE CLEANING
CABINET
Inside
and
Outside
(Stainless Steel)
STUBBORN SPOTS AND STAINS
BURNT-ON FOODS OR GREASE
HARD WATER SPOTS and SCALE
*Mild detergents include soaps and non-abrasive cleaners.
Note: Gaskets are removable for cleaning.
Soap, Ammonia, or mild *detergent and water.
Mild abrasive made for stainless steel.
Chemical oven cleaner for stainless steel.
Vinegar
1. Sponge on with cloth.
2. Rinse with water.
3. Wipe dry.
1. Apply with damp sponge or cloth.
2. Rub lightly. Follow oven cleaner manufacturer’s
directions.
1. Swab or wipe with cloth.
2. Rinse and dry.
Page 4
Insulated
Hot Cabinets
FL-2253
Rev. 15 (6/08 Page 4 of 6
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WSUA...C & H137WS18...C Series
Humidity Holding Hot Cabinet
REPLACEMENT PARTS:
120V 208V 240V
Power Unit 2000W 0675-003 0675-009 0675-009
2000W + dig thrm 0675-003-D 0675-009-D 0675-009D
Heater Kit, Air 2000W 0811-268 0811-269 0811-270
1000W 0811-074 0811-074-02 0811-074-1 Heater Kit, Water 1850W 0811-271 0811-271 High Limit 0848-060 0848-060 0848-060 Thermometer Analog 5238-030 5238-030 5238-030
Digital 5238-034 5238-034 5238-034
Transformer (used with digital thermometer)
0769-159 0769-159 0769-159
Thermostat, Air Solid State 0848-008-ACK 0848-008-ACK 0848-008-ACK Thermostat, Water Solid State 0848-008-ACK 0848-008-ACK 0848-008-ACK Relay 0857-130 0857-102 0857-102 Power Cord 2000W 0810-065-12 0810-039-07 0810-039-07 Power Switch 0808-116 0808-116 0808-116 Power Light 0766-094 0766-095 0766-095 Vent Fan 0769-165 0769-174 0769-174 Blower Kit 0769-180-K 0769-182-K 0769-182-K
Door, Complete (Stainless Steel)
Door, Gasket (Stainless Steel)
Door Hinge (Stainless Steel)
UA12/UA6/1834/1816 1221-525 UA5/185 1221-545
UA9 1221-526 UA12/UA6/1834/1816 0861-185 UA5/185 0861-250
UA9 0861-182
0519-074-K
Door Latch All Models 1006-122-01-K
Page 5
Insulated
Hot Cabinets
FL-2253
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WSUA...C & H137WS18...C Series
Humidity Holding Hot Cabinet
WIRING DIAGRAM: 120V
SENSOR
TRANSFORMER 110V/220V
8
24 351
19
17 18
121413
45
WATER THERMOSTAT
20
1615
10 9 4 5 6 7
8
AIR THERMOSTAT
Rev. 15 (6/08)) Page 5 of 6
HEATER WATER
768910
9
21
68
6
C.
C.
A
RELAY
N.C.
N.O.
N.C.
N.O.
1110
11
5
B
7
OPTIONAL
POWER SWITCH
HIGH LIMIT
BLOWER
MOTOR
3
TERMINAL BLOCK
1
2
VENT
FAN
9
21
5-20P
W
120V; 20A
G
A
POWER LIGHT
45
HEATER AIR
Page 6
Insulated
Hot Cabinets
FL-2253
Rev. 15 (6/08 Page 6 of 6
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WSUA...C & H137WS18...C Series
SENSOR
TRANSFORMER 110V/220V
5 8
4 3 21
5925 Heisley Road • Mentor, OH 44060-1833
Humidity Holding Hot Cabinet
WIRING DIAGRAM: 208V/240V
1413
10
9 8 4 5
WATER THERMOSTAT
1615
10
9 8
AIR THERMOSTAT
19
20
18
17
12
6 7
8
4 566 7
HEATER WATER
10
11
RELAY
C.
9
C.
21
6 7
N.C.
11
N.O.
N.C.
N.O.
5
A
B
6-15P PLUG 240V, 15A
208V, 15A
OPTIONAL
W
TERMINAL BLOCK
POWER SWITCH
1
2
B
A
G
POWER LIGHT
HIGH LIMIT
3
BLOWER
MOTOR
9
VENT
FAN
21
45
HEATER AIR
Loading...