Pass-Thru
Hot Cabinet
FL-2254
5925 Heisley Road • Mentor, OH 44060-1833
Rev. 7 (7/08) Page 1 of 5
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137PUA...C/H138P1834C and H137PSUA...C/H138PS1834C
Pass-Thru Series Hot Cabinets
ELECTRICAL SPECIFICATIONS:
Model No. Volts Watts Amps Hertz Phase NEMA
H137PSUA12C
H137PUA12C
H137PSUA9C
H137PUA9C
H137PSUA6C
H137PUA6C
H138PS1834C
H138P1834C
H137PSUA12C208
H137PUA12C208
H137PSUA9C208
H137PUA9C208
H137PSUA6C208
H137PUA6C208
H138PS1834C208
H138P1834C208
120 2000 16.7 60 1 5-20P
208 2000 10.0 60 1 6-15P
H137PSUA12C240
H137PUA12C240
H137PSUA9C240
H137PUA9C240
H137PSUA6C240
H137PUA6C240
H138PS1834C240
H138P1834C240
240 2000 8.6 60 1 6-15P
Note: The above model numbers are basic models. They may be followed by letters: L, M, 2M, D or
ending with S and/or Z
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE
PERSONNEL ONLY
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Pass-Thru
Hot Cabinet
FL-2254
Rev. 7 (7/08) Page 2 of 5
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137PUA...C/H138P1834C and H137PSUA...C/H138PS1834C
Pass-Thru Series Hot Cabinets
HOW TO INSTALL UNIT:
Place cabinet on level fl oor.1.
Plug cord into proper wall outlet. 2.
Power Switch
Yellow Light
Thermostat
Thermometer
HOW TO START UNIT:
Push 1. POWER switch to ON. The yellow light will
turn on.
Turn thermostat knob to #7.2.
Preheat cabinet for 60 minutes.3.
Put food into cabinet.4.
Turn thermostat to #8 and close door.5.
No. 8 setting = approx. 185°F/85°C
No. 6 setting = approx. 160°/71°C
No. 4 setting = approx. 130°/54°C
NOTE: Proper food holding temperature is
140°F/60°C or higher.
Note: The optional digital thermometer display
fl ashes when center of cabinet is below 140°F
(60°C) or above 250°F (121°C). Call the
factory if you need different settings.
TO TURN OFF UNIT:
Push the POWER switch to OFF.
The yellow light will go out.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com