5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H135UA11-J Series Hot Cabinet
Model No. Volts Watts Amps Hertz Phase NEMA
H135UA11J1 100 1400 14 50/60 1 5-15P
Designed for AC service.
Hot Cabinets
Rev. 1 (3/07) Page 1 of 4
FL-2328-J
CONTROL PANEL PARTS IDENTIFICATION
1. Power Switch
2. Yellow Light-Power
3. Thermostat
4. Thermometer
HOW TO INSTALL UNIT:
Place cabinet near warm ovens. Do NOT put in
1.
drafty areas or near ventilating systems.
Plug cord end into proper wall outlet.
2.
HOW TO START UNIT:
Turn the POWER switch on. The yellow light will
1.
turn on.
Turn thermostat to #10.
2.
Preheat cabinet for 30 minutes.
3.
Put food into cabinet.
4.
Turn thermostat to #8 and close door.
5.
NOTE: No. 8 setting = approx. 88°C (190°F)
No.6 setting = approx. 74°C (165°F)
Proper food holing temperature is 60°C (140°F) or
higher. The thermometer shows the temperature inside.
TO TURN OFF UNIT:
Turn thermostat off.
1.
Turn the POWER switch off.
2.
The yellow light will go out.
3.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Hot Cabinets
Rev. 1 (3/07) Page 2 of 4
FL-2328-J
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H135UA11-J Series Hot Cabinet
MAINTENANCE
HOT UNIT REMOVAL INSTRUCTIONS:
Unplug power cord from wall outlet.
1.
Pull entire unit out the front of the cabinet.
2.
HOW TO CLEAN THE CABINET:
5925 Heisley Road • Mentor, OH 44060-1833
BEFORE cleaning
the cabinet:
Allow cabinet to cool.
1.
Remove Hot unit from cabinet.
2.
Do NOT use abrasives or harsh
3.
chemicals.
HOW TO CLEAN THE UNIT:
SOIL CLEANER METHOD
DOOR
and
CABINET
Inside and
Outside
(Aluminum)
DIRT
FINGERPRINTS,
GREASE OIL
WATER SPOTS Mild abrasive cleaner.
* Mild detergents include soaps and non-abrasive cleaners
Mild detergent* and hot water, or mild
abrasive cleaner.
Steam (no strong alkaline additive)
Chemical oven cleaner for aluminum.
Mild abrasive cleaner;
oily or waxy cleaner.
Cleaning Notes:
Wipe up spills as soon as possible.
1.
Clean cabinet regularly to avoid heavy dirt build-up.
2.
Make a test spot with cleaner.
3.
Follow manufacturer’s directions on cleaner.
4.
Do not mix cleaners.
5.
Avoid drips and splashes.
6.
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
1. Rinse after steam cleaning.
2. Wipe dry.
Follow oven cleaner
manufacturer’s directions.
Apply with soft, clean cloth.
1. Wipe with damp cloth.
2. Rinse and dry.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Hot Cabinets
Rev. 1 (3/07) Page 3 of 4
FL-2328-J
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H135UA11-J Series Hot Cabinet
TROUBLE-SHOOTING CHART:
FAILURE POSSIBLE CAUSE
1. Yellow light at switch does NOT light
2. Unit does not heat.
3. Unit gets too hot or won’t shut off. 3a. Defective electrical parts. UNPLUG UNIT
4. Blower does not work or make noise. 4a. Defective blower.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
1a. Circuit breaker/fuse to wall outlet is blown.
1b. Cord is unplugged from wall outlet.
1c. Switch is “OFF”.
2a. Thermostat set too low or is “OFF”.
2b. Switch is “OFF”.
FROM WALL OUTLET.
REPLACEMENT PARTS:
DESCRIPTION 120 VOLT
Hot Unit HU1254058J
Blower Kit 0769-005-K
Heater Kit 0811-022
Thermostat Kit 0848-062-K
Thermometer Kit (Analog) 5238-030-K
Power Cord 0810-171
Power Switch 0808-116
Pilot Light 0766-094
Terminal Block 0852-091
CABINET
Door Latch 1006-154-01
Door Hinge 0519-104
Pan Slides 0621-181
Door Assembly 1200-495-BL
Door Gasket 0861-234
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Hot Cabinets
Rev. 1 (3/07) Page 4 of 4
FL-2328-J
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H135UA11-J Series Hot Cabinet
WIRING DIAGRAM:
5925 Heisley Road • Mentor, OH 44060-1833
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com