Owner’s Manual
Permanently Lubricated Single Stage Side Stack
AIR COMPRESSOR
Model No.
919.724582
• Safety Guidelines
• Assembly
• Operation
• Service and Adjustments
• Troubleshooting
• Repair Parts
CAUTION: Read the Safety Guidelines
and All Instructions Carefully Before Operating.
Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8
A07187 Rev. 1 12/6/04
TABLE OF CONTENTS
WARRANTY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SPECIFICATION CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SAFETY GUIDELINES-DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . 3-8
GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
DUTY CYCLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-14
MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-16
SERVICE AND ADJUSTMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-21
REPAIR PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-25
HOW TO ORDER REPAIR PARTS . . . . . . . . . . . . . . . . . . . . . .Back Cover
WARRANTY
FULL ONE YEAR WARRANTY
If this CRAFTSMAN Inflator fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge. Contact your nearest Sears Service Center (1-800­4-MY-HOME®) to arrange for product repair, or return the CRAFTSMAN product to the place of purchase for replacement.
If this Air Compressor is used for commercial or rental purposes, this warranty applies for only ninety days from the date of purchase.
This warranty gives you specific legal rights and you may also have other rights which vary from province to province.
Sears Canada, Inc. Toronto, Ont. M5B 2B8
A07187
2- ENG
SPECIFICATION CHART
Model No. 919-724582
Max. Developed HP 3 Bore 2.375" Stroke 1.35" Voltage-Single Phase 120 Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity - Gallons 4 Approximate Cut-in Pressure 120 Approximate Cut-out Pressure 150 SCFM@ 40 psig 7.9 SCFM@ 90 psig 5.5
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols.
Indicates an imminently hazardous
situation which, if not avoided, will result in death or serious injury.
which, if not avoided, may result in minor
or moderate injury.
Indicates a potentially hazardous situation
Indicates a potentially hazardous situation
which, if not avoided, could result in
death or serious injury.
indicates a potentially hazardous situation which, if not avoided, may result in
property damage.
Used without the safety alert symbol
IMPORTANT SAFETY INSTRUCTIONS
Some dust created by power sanding, sawing, grinding,
drilling, and other construction activities contains chemicals known (to the State of California) to cause cancer, birth defects or other reproductive harm. Some example of these chemicals are:
lead from lead-based paints
crystalline silica from bricks and cement and other masonry products
arsenic and chromium from chemically-treated lumber Your risk from these exposures varies, depending on how often you do
this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, always wear MSHA/NIOSH approved, properly fitting face mask or respirator when using such tools.
When using air tools, basic safety precautions should always be followed to reduce the risk of of personal injury.
3- ENG
A07187
IMPORTANT SAFETY INSTRUCTIONS
Save these instructions
Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
HAZARD
WARNING: Risk of explosion or fire
What Could Happen
It is normal for electrical contacts within the motor and pressure switch to spark.
If electrical sparks from compressor come into contact with flammable vapors, they may ignite, causing fire or explosion.
Restricting any of the compressor ventilation openings will cause serious overheating and could cause fire.
Unattended operation of this product could result in personal injury or property damage. To reduce the risk of fire, do not allow the compressor to operate unattended.
How To Prevent It
Always operate the compressor in a well ventilated area free of combustible
materials, gasoline, or solvent vapors.
If spraying flammable materials, locate compressor at least 20 feet away from spray area. An additional length of hose
may be required.
Store flammable materials in a secure location away from compressor.
Never place objects against or on top of compressor. Operate compressor in an open area at least 12 inches away from any wall or obstruction that
would restrict the flow of fresh air to the ventilation openings.
Operate compressor in a clean, dry well ventilated area. Do not operate unit
indoors or in any confined area. Always remain in attendance with the
product when it is operating.
Always disconnect electrical power by moving pressure switch lever to the off position and drain tank daily or after each use.
A07187
4- ENG
HAZARD
WARNING: Risk of Bursting
Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury.
What Could Happen
Failure to properly drain condensed water from tank, causing rust and thinning of the steel tank.
Modifications or attempted repairs to the tank.
Unauthorized modifications to the unloader valve, safety valve, or any other components which control tank pressure.
Excessive vibration can weaken the air tank and cause rupture or explosion
ATTACHMENTS & ACCESSORIES:
Exceeding the pressure rating of air tools, spray guns, air operated accessories, tires, and other inflatables can cause them to explode or fly apart,
and could result in serious injury.
HAZARD
How To Prevent It
Drain tank daily or after each use. If tank
develops a leak, replace it immediately with a new tank or replace the entire compressor.
Never drill into, weld, or make any modifications to the tank or its
attachments.
The tank is designed to withstand specific operating pressures. Never make
adjustments or parts substitutions to alter the factory set operating pressures.
For essential control of air pressure, you must install a pressure regulator and pressure gauge to the air outlet (if not equipped) of your compressor. Follow the
equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments. Never
use compressor to inflate small low pressure objects such as children’s toys, footballs, basketballs, etc.
WARNING: Risk from Flying Objects
What Could Happen
The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles,
and small objects at high speed, resulting in property damage or personal injury.
How To Prevent It
Always wear ANSI Z87.1 approved safety glasses with side shields when using the
compressor.
Never point any nozzle or sprayer toward any part of the body or at other people or animals.
Always turn the compressor off and bleed pressure from the air hose and tank
before attempting maintenance, attaching tools or accessories.
5- ENG
A07187
HAZARD
WARNING: Risk of Electrical Shock
What Could Happen
Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock.
Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
Electrical Grounding: Failure to provide adequate grounding to this product could result in serious injury or death from electrocution.
See grounding instructions.
HAZARD
WARNING: Risk to Breathing
What Could Happen
The compressed air directly from your compressor is not safe for breathing. The air stream may contain carbon
monoxide, toxic vapors, or solid particles from the tank. Breathing these contaminants can cause serious injury or death.
How To Prevent It
Never operate the compressor outdoors when it is raining or in wet conditions.
Never operate compressor with protective covers removed or damaged.
Any electrical wiring or repairs required on this product should be performed by authorized service center personnel in accordance with national and local electrical codes.
Make certain that the electrical circuit
to which the compressor is connected
provides proper electrical grounding, correct voltage and adequate fuse protection.
How To Prevent It
Air obtained directly from the compressor should never be used to supply air for human consumption. In order to use air
produced by this compressor for breathing, suitable filters and in-line safety equipment must be properly installed. In-line filters and safety equipment used in conjunction with the compressor
must be capable of treating air to all applicable local and federal codes prior to human consumption.
Sprayed materials such as paint, paint
solvents, paint remover, insecticides, weed killers, may contain harmful
vapors and poisons.
A07187
Work in an area with good cross ventilation. Read and follow the safety instructions provided on the label or safety data sheets for the materials you are spraying. Use a NIOSH/ MSHA approved respirator designed for use with
your specific application.
6- ENG
HAZARD
WARNING: Risk of Burns
What Could Happen
Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns.
WARNING: Risk from Moving Parts
What Could Happen
Moving parts
and belt can cause serious injury they come into contact with you or your clothing.
Attempting to operate damaged or missing parts
to repair compressor with protective shrouds removed can expose you to moving parts and
injury.
such as the pulley, flywheel,
compressor with
can result in serious
if
or attempting
WARNING: Risk of Falling
How To Prevent It
Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation.
Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool.
HAZARD
How To Prevent It
Never operate the compressor with guards or covers which are removed.
Any repairs should be performed by authorized service center personnel.
required on this product
HAZARD
damaged or
What Could Happen
A portable a table, workbench, or roof c
damage to the compressor and could result in serious injury or death to the operator.
compressor can fall
ausing
from
How To Prevent It
Always
operate compressor in a stable
secure position
movement of the unit.
compressor on a roof or other elevated position. Use additional air hose to reach high locations.
7- ENG
to prevent accidental
Never operate
A07187
HAZARD
WARNING: Risk of Serious Injury or Property Damage When Transporting Compressor
(Fire, Inhalation, Damage to Vehicle Surfaces)
What Could Happen
Oil can leak or spill and could result
in fire or breathing hazard; serious injury or death can result. oil leaks will damage carpet, paint or other surfaces in vehicles or trailers.
Always place COMPRESSOR on a protective mat when transporting to protect against damage to vehicle from leaks. Remove COMPRESSOR from vehicle immediately upon arrival at your destination.
How To Prevent It
HAZARD
WARNING: Risk of Unsafe Operation
What Could Happen
Unsafe operation of your air compressor could lead to serious injury or death to you or others.
SAVE THESE INSTRUCTIONS
How To Prevent It
Review and understand all instructions and warnings in this manual.
Become familiar with the operation and controls of the air compressor.
Keep operating area clear of all persons,
pets, and obstacles. Keep children away from the air
compressor at all times.
Do not operate the product when fatigued or under the influence of alcohol or drugs. Stay alert at all times.
Never defeat the safety features of this
product.
Equip area of operation with a fire extinguisher.
Do not operate machine with missing, broken, or unauthorized parts.
A07187
8- ENG
GLOSSARY
Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute. SCFM: Standard cubic feet per
minute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge; a unit of measure of pressure.
Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory.
When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called "cut-out" pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.
ACCESSORIES
This unit is capable of powering the following accessories. The accessories are available through the current Power and Hand Tool Catalog or full-line Sears stores.
Accessories
In Line Filter
Tire Air Chuck
Quick Connector Sets (various
sizes)
Air Pressure Regulators
Oil Fog Lubricators
DUTY CYCLE
This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75% average duty
Air Hose:1/4", 3/8" or 1/2" I.D. in various lengths
Refer to the selection chart located on the unit to select the tools this unit is capable of powering.
cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour.
9- ENG
A07187
ASSEMBLY
Unpacking
1. Remove unit from carton and discard all packaging.
INSTALLATION
HOW TO SET UP YOUR UNIT
Location of the Air Compressor
Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.
IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.
2. Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.
Plug
Grounded Outlets
Grounding Pin
GROUNDING INSTRUCTIONS
Risk of Electrical
Shock. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances.
1. The cord set and plug with this
unit contains a grounding pin. This plug MUST be used with a grounded outlet.
A07187
3. Inspect the plug and cord before each use. Do not use if there are signs of damage.
4. If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.
Risk of Electrical
Shock. Improper grounding can result in electrical shock.
Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.
Repairs to the cord set or plug MUST be made by a qualified electrician.
10- ENG
Extension Cords
Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating.
Instead of using an extension cord, increase the working reach of the air hose by attaching
If an extension cord must be used, be sure it is:
a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product
in good condition
no longer than 50 feet
12 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)
Voltage and Circuit Protection
Refer to the Parts Manual for the voltage and minimum branch circuit requirements.
Risk of Unsafe
Operation. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met.
1. Voltage supply to circuit must
comply with the National Electrical Code.
2. Circuit is not used to supply any
other electrical needs.
3. Extension cords comply with
specifications.
4. Circuit is equipped with a
15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked “D” in Canada and “T” in the US.
If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.
11- ENG
A07187
OPERATION
Know Your Air Compressor
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.
Tank
Pressure
Gauge
On/
Auto/Off
Switch
Outlet
Pressure
Gauge
Description of Operation
Become familiar with these controls before operating the unit.
On/Auto/Off Switch: Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use.
Pressure Switch: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.
Safety Valve (not shown): If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).
Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side
Pressure
Switch
Regulator
Air
Compressor
Pump
Universal
Quick
Connect
Bodies
of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.
Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.
Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place.
Universal Quick-Connect Body: The universal quick-connect body accepts the three most popular styles of quick-connect plugs- Industrial, automotive (Tru-flate), and ARO. One hand push-to-connect operation makes connections simple and easy. The two quick connect bodies allow the use of two tools at the same time.
A07187
12- ENG
Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.
Air Compressor Pump: Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.
Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.
Check
Valve
Drain Valve
Check Valve: When the air
compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.
Pressure Release Valve: The pressure release valve located on the side of the pressure switch, is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches "cut-out" pressure or is shut off. The pressure release valve allows the motor to restart freely. When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running, or continuous leaking after unit reaches "cut-out" pressure.
Pressure
Release
Valve
How to Use Your Unit
How to Stop
1. Set the On/Auto/Off lever to "OFF".
Before Starting
Break-in instructions
damage may result if the following break-in instructions are not closely followed.
This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
1. Make sure the On/Auto/Off lever is in the "OFF" position.
NOTE: If quick connect is installed, pull coupler back until it clicks to prevent air from escaping through the quick connect.
2.
Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)
3. Open the drain valve fully (counter-clockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.
4. Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start.
:
Risk of Unsafe Operation. Serious
13- ENG
A07187
5. Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.
6. After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.
The compressor is now ready for use.
Before Each Start-Up:
1. Place On/Auto/Off lever to "OFF".
2. Pull regulator knob out, turn counter-clockwise until it stops. Push knob in to lock in place.
3. Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect.
Risk of Bursting.
Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.
How to Start:
1. Turn the On/Auto/Off lever to "AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.
2. Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place. The compressor is ready for use.
NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.
A07187
14- ENG
Loading...