Craftsman 706.596690 User Manual

Page 1
706.596680 6-Drawer Chest
Owners
706.596690 7-Drawer Roll-A-Way
Craftsman 7-Drawer Roll-Away Craftsman 6-Drawer AXS™ Chest
Manual
Section Description
1612 1613 1614 1615 1616 1617 1618 Locking System 1623 Lock Replacement 1624 1625
Chest Top and Facia Drawer and Work Surface Bottom Replacement Top, Wiring Harness, Harness Grommet Chest Top without Task Light Task Light Replacement
Striker Replacement Drawer Front Replacement
Page 2
CRRFTSMRN

CHEST TOP AND FACIA

PARTS REPLACEMENT
Information Center
Sears, Roebuck and Co., Hoffman Estates, IL 60179, USA
F1612
Page 3
CHEST TOP INSTALLATION AND REMOVAL
Tools Required:
3/8" Wrench
(With task light)
Chest Top Removal
• Disconnect power from unit.
• Remove enough drawers to reach the top back inside of the unit. {See Drawer installation and removal.)
• Push actuator rod to back of unit to disconnect from back of lock. Move actuator rod for access.
• Remove (4) screws holding top in place.
• Lift top off of unit enough to reach the wiring harness.
• Disconnect wiring harness from unit.
• Remove top from unit.
Chest Top installation
• Connect wiring harness to top.
• Position top on unit.
• Attach using (4) screws.
• Make sure the back of the actuator rod is inserted into the actuator rod holder in the back of the unit.
• Push actuator rod toward back of unit and line up with lock. Insert the actuator rod into the back of the lock.
• Test lock operation.
• Reinstall drawers.
• Reconnect power to the unit.
Page 4
INFORMATION CENTER INSTALLATION
Tools Required:
Screwdriver, Crosstip Tape
AND REMOVAL
Removal
• Disconnect power from the unit.
• Remove enough drawers to reach the retaining screw under the information center. (See removing and installing drawers.)
• Loosen (do not remove) the retaining screw under the information center.
• Pull the information center straight out to remove.
Note: Tape wire to unit before unplugging the information center. This wiil prevent the wire from retracting into the unit.
• Unplug the information center.
Tape wire in
Installation
• Plug in information center.
• Position information center in unit.
• Tighten retaining screw enough to hold information center in place. Do not overtighten.
• Reinstall drawers. (See Removing and installing drawers.)
• Reconnect power to unit.
• Set information center as desired. (See information center operation.)
Press to
Page 5
FACIA INSTALLATION AND REMOVAL
Tools Required:
3/8" Wrench drill 5/32" drill bit Rivet gun Pliers
To remove facia
• Remove enough drawers to reach the top back inside of the chest.
• Remove lock. (See lock installation and removal.)
• Remove chest top. See chest top installation and removal.
• Carefully drill out (2) rivets holding facia to chest.
• Remove facia.
To reinstall facia
• Position facia on unit. Make sure connector is on top of chest.
• Attach using (2) rivets supplied.
• Reinstall lock, chest top, and drawers.
LOCK INSTALLATION AND REMOVAL
Rivet
LOCK INSTALLATION AND REMOVAL
To remove lock
• Remove enough drawers to reach the lock retaining clip behind the lock.
• Remove lock retaining clip. Pull lock out to remove.
To reinstall lock
• Position lock in unit. Install retaining clip to hold lock in place.
• Make sure the back of the actuator rod is inserted into the actuator rod holder in the back of the unit.
• Push actuator rod toward back of unit and line up with lock. Insert the actuator rod into the back of the lock.
• Test lock operation.
• Reinstall drawers.
Lock
Page 6
CONNECTING POWER
• Ensure that the unit and power cord are clean and dry.
• Insert the round end of the power cord connector into the jack in the back of the unit.
• Plug the cord into an appropriate electrical outlet.
Fuse block
To reinstall, carefully align the slides and push the drawer into the unit until the drawer stops.
INFORMATION CENTER OPERATION
The information center is equipped with a battery backup to maintain memory only. The display will not function while power is disconnected from the unit.
REMOVING AND INSTALLING DRAWERS:
• Empty the drawer.
• Fully extend the drawer.
Release
Lever Style - Lift or
ower (depending on the slide) the release lever on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
Tab Style - Depress the
release tabs on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
Outside temperature display requires optional outside temperature sensor.
Display backlight
• Pressing ( tight ) turns the display backlight on for 15 seconds.
Setting the current time
• Press and hold { Clock Set) for at least two seconds. (Second resets to zero and hour begins to flash.)
• Press ( Clock) to set am/pm or 24 hour mode as desired. Note: The am/pm indicator is not shown in 24 hour mode.
• Adjust hour using (T) and Q.
• Pressing ( Clock') toggles to next field. Note: To toggle to minute without changing hour, press (T) then Q then
C Clock y
• Adjust minute using (¿) and Q.
• Press ( Clock ) to toggle to next field.
• Repeat to adjust Month, Day, and
Year.
• Toggling past year exits set mode.
• Day of week is displayed according to Month, Day, and Year.
Page 7
Temperature Display
Pressing ( °fc ) toggles inside and outside temperature displays between Celsius and Fahrenheit.
• Pressing ( Temp ) toggles inside and outside temperature displays between
• ACT (Actual temperature)
• MIN (Minimum recorded
temperature since last reset)
MAX (Maximum recorded
temperature since last reset)
• Press and hold ( Temp ') for at least two seconds to clear inside and outside minimum and maximum recorded temperatures.
• An audible beep will sound when temperature is reset.
Setting the alarm
• Press and hold ( Alarm Set ) for at least two seconds. (Second resets to zero and hour begins to flash.)
• Adjust hour using (J) and Q-
• Pressing ( Alarm ') toggles to next field.
• Repeat to adjust minute.
• Toggling past minute exits set mode.
Turning alarm on or off
When the alarm is activated, the display will show the indicator
• Press ( Alarm ) to activate or deactivate the alarm.
• Press () Alarm ) to Silence alarm when ringing.
Timer function
• Press ( Timer) to enter timer mode.
• Press ((start/stop ) to Start timer.
• Each time ( start/stop ) is pressed starts or stops timer.
• Press and hold Q start/stop ^ for at least
two seconds to reset timer to zero.
Count down timer function
• Press and hold ( Timer') for at least two seconds.
• Display shows 00:00:00 and hour begins to flash.
• Adjust hour using (+) and Q .
• Pressing ( Timer ~) toggles to next field.
• Repeat to adjust minute and second.
• Toggling past second exits set mode. Note: To set timer to 24 hours, toggle display to 00:00:00.
• Press ( start/stop ) to Start count down.
• Each time ( start/stop } is pressed starts or stops timer.
• Alarm sounds when timer reaches 00:00:00.
• Press any button to silence the alarm.
Clock
When in Timer or Count down timer mode, press ( Clock) to display current time. Press ( Timer) to return to timer or count down timer.
Alarm
Page 8
CRRFTSMRN

DRAWER AND WORK SURFACE

PARTS REPLACEMENT
Sears, Roebuck and Co., Hoffman Estates, IL 60179, USA
F1613
Page 9
Tools Required:
Drill 5/32" Drill bit Rivet gun
SLIDE REPLACEMENT
Removal
• Remove drawer or work surface from unit. (See drawer and work surface installation and removal.)
• Carefully drill out rivet holding slide drawer member to drawer or work surface.
• Rotate front of slide drawer member down and out.
• Pull slide forward to remove.
• Carefully drill out rivet holding slide unit member in place.
• Pull slide unit member forward to remove.
Installation
• Separate slide drawer member from unit member. (See drawer and work surface installation and removal.)
• Install new slide unit member. (Install back hanger first.)
• Rivet unit member in place as shown.
• Install drawer member. (Install back hanger first.)
• Install rivet to hold slide drawer member in place.
• Reinstall drawer or work surface into unit. (See drawer and work surface installation and removal.)
Page 10
DRAWER AND WORK SURFACE REPLACEMENT
Tools Required:
Drill 5/32" Drill bit Rivet gun Crosstip screwdriver
Removal
• Remove drawer or work surface from unit. (See Drawer and Work surface installation and removal.)
• Carefully drill out rivets holding slides to drawer.
• Rotate front of slide down and out.
• Pull slide forward to remove.
Drawers only
• Remove striker. (See striker replacement.)
• Remove drawer front. (See drawer front replacement.)
Right side
Installation
• Install slides on new drawer or work surface. (Install back hangers first.)
• Install rivets to hold slides in place.
Drawers only
• Install striker. (See striker replacement.)
• Install drawer front. (See drawer front replacement.)
Drawers and work surface
• Install drawer or work surface in unit. See drawer and work surface
installation and removal.
Slide
Page 11
DRAWER FRONT INSTALLATION AND REMOVAL
Tools Required:
Crosstip screwdriver
Removal
• Remove retaining screw(s).
• Slide drawer front assembly as indicated to unhook mounting tabs.
• Pull out to remove.
Installation
• Position drawer front on drawer assembly.
• Insert mounting tabs into notches on drawer.
• Slide drawer front over to attach.
• Install retaining screw(s) to hold drawer front in place.
Page 12
DRAWER AND WORK SURFACE INSTALLATION AND REMOVAL
Note: For pull out work surface without task light, follow drawer removal instructions.
DRAWER
• Empty the drawer.
• Fully extend the drawer.
Release
Lever Style - Lift or
ower (depending on the slide) the release lever on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
Tab Style - Depress the
release tabs on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
To reinstall, carefully align the slides and push the drawer into the unit until the drawer stops.
PULL OUT WORK SURFACE WITH TASK LIGHT Removal
• Disconnect the power from the unit.
• Remove enough drawers to gain access to connections in the back of the roll-away behind the work surface.(Follow drawer removal instructions.)
Page 13
Unplug work surface cord from back of roll-away. Remove and save back retaining clip. Disconnect chain inside back of roll­away. (Move chain toward large round part of slot. Pull out to remove.) Remove the work surface. (See drawer removal instructions.)
Retaining
Installation
• To reinstall, carefully align the slides
and push the work surface into the unit until the work surface stops.
• Depress release tabs in back corners
of the extendable work surface.
• Push the work surface into the unit to the fully retracted position.
• Extend work surface far enough to
gain access to connections in back.
• Connect chain inside back of roil
away. (Insert chain into the large round part of the slot. Slide chain to small end of slot.)
• Insert retaining clip to hold chain in
place.
• Plug work surface cord into back of
roll-away.
• Reconnect power to the unit. (See:
Connecting power.)
• Check work surface and task lighting for proper operation.
• Reinstall drawers.
Page 14
Tools Required:
Socket Wrench 5/16" Socket
CRRFTSMRN

BOTTOM REPLACEMENT

Removal
• Disconnect power from the unit.
• Remove contents from drawers.
• Carefully lay the chest on its back. Take care to prevent scratches or damage to the unit.
• Remove (5) screws holding bottom on unit.
• Remove bottom from unit.
• Remove counterweight from plastic bottom.
Installation
• Install counterweight in new plastic bottom.
• Position new chest bottom on chest.
• Attach using (5) new mounting screws.
• Return the chest to its upright position.
• Reconnect power to the unit.
F1614
Page 15
Page 16
CRRFTSMRN

TOP, WIRING HARNESS, HARNESS GROMMET

Parts Replacement
Sears, Roebuck and Co., Hoffman Estates, IL 60179, USA
Harness grommet
F1615
Page 17
Tools Required:
3/8" Wrench
WIRING HARNESS REPLACEMENT
HARNESS GROMMET REPLACEMENT
WIRING HARNESS AND HARNESS GROMMET REMOVAL
• Disconnect power from unit.
• Remove pull out work surface and enough drawers to reach the top back inside of the unit. (See drawer and work surface installation and removal.)
• Remove lock and top from roll-away. (See roll-away top removal and installation.)
• Remove harness grommet from roll­away.
WIRING HARNESS REMOVAL
• For units with accent lighting under roll-away, remove bottom drawer and disconnect accent lighting.
• Remove wiring harness through hole in roll-away top.
WIRING HARNESS AND HARNESS
GROMMET INSTALLATION
• Insert new wiring harness assembly into mounting track through hole in top of roll-away (connector should be on
top.) Slide wiring harness assembly to bottom of roll-away.
• Install harness grommet over
connector. Insert into hole in top of roll-away.
• Reinstall top and lock
• If unit has accent lighting, reconnect
accent lighting.
• Test lock operation.
• Reinstall drawers.
• Reconnect power to the unit.
Harness Grommet
Page 18

TOP INSTALLATION AND REMOVAL

Tools Required:
Screwdriver, Crosstip
Roll-away top removal
• Disconnect power from unit.
• Remove pull out work surface. (See drawer and work surface installation and removal.)
• Remove enough drawers to reach the top back inside of the unit. (See Drawer and Work surface installation and removal.)
• Remove lock retaining clip. Pull lock out to remove.
• Remove (4) screws holding top in place.
• Lift top off of unit enough to reach the
wiring harness.
• Disconnect wiring harness from unit.
• Remove top from unit.
Roll-away top installation
• Connect wiring harness to top. Position top on unit. Attach using (4)
screws.
• Position lock in unit. Install retaining
clip to hold lock in place.
• Make sure the back of the lock rod is inserted into the lock rod holder in the
back of the unit.
• Push the lock rod toward the back of
unit the and line up with lock. Insert the lock rod into the back of the lock.
• Test lock operation.
• Reinstall drawers.
• Reinstall work surface.
• Reconnect power to the unit.
Page 19
DRAWER AND WORK SURFACE INSTALLATION AND REMOVAL
Note: For pull out work surface without
task light, follow drawer removal
instructions.
DRAWER
• Empty the drawer.
• Fuliy extend the drawer.
Release
Lever Style - Lift or
ower (depending on the slide) the release lever on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
Tab Style - Depress the
release tabs on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
To reinstall, carefully align the slides
and push the drawer into the unit until the drawer stops.
PULL OUT WORK SURFACE WITH
TASK LIGHT
Removal
• Disconnect the power from the unit.
• Remove enough drawers to gain access to connections in the back of
the roll-away behind the work surface.
Unplug work surface cord from back of
roll-away.
Remove and save back retaining clip.
Disconnect chain inside back of roll­away. (Move chain toward large round part of slot. Pull out to remove.)
Remove the work surface. (See drawer removal instructions.)
Retaining
To reinstall, carefully align the slides and push the work surface into the unit until the work surface stops.
Depress release tabs in back corners of the extendable work surface. Push the work surface into the unit to the fully retracted position.
Extend work surface far enough to gain access to connections in back. Connect chain inside back of roil away. (Insert chain into the large round part of the slot. Slide chain to small end of slot.)
Insert retaining clip to hold chain in place. Plug work surface cord into back of roll-away.
Reconnect power to the unit. (See: Connecting power.) Check work surface and task lighting for proper operation.
Reinstall drawers.
Page 20

CHEST TOP WITHOUT TASK LIGHT

Tools Required:
Screwdriver, Crosstip
CRRFTSMRN
Chest top removal
• Disconnect power from unit.
• Remove pull out work surface. (See drawer installation and removal.)
• Remove enough drawers to reach the top back inside of the unit. (See Drawer installation and removal.)
• Remove lock retaining clip. Pull lock out to remove.
• Remove (4) screws holding top in place.
• Remove top from unit.
Chest top installation
• Position top on unit. Attach using (4) screws.
• Position lock in unit. Install retaining clip to hold lock in place.
• Make sure the back of the lock rod is
inserted into the lock rod holder in the
back of the unit.
• Push the lock rod toward the back of unit the and line up with lock. Insert the lock rod into the back of the lock.
• Test lock operation.
• Reinstall drawers.
• Reconnect power to the unit.
Sears, Roebuck and Co., Hoffman Estates, IL 60179, USA
F1616
Page 21
DRAWER INSTALLATION AND REMOVAL
Empty the drawer. Fully extend the drawer.
Release
Lever Style - Lift or
ower (depending on the slide) the release lever on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
Tab Style - Depress the
release tabs on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
To reinstall, carefully align the slides and push the drawer into the unit until the drawer stops.
Page 22
Tools Required:
Screwdriver, Crosstip
CRRFTSMRN

TASK LIGHT REPLACEMENT

Removal
• Disconnect power from the unit.
• Fully extend task light assembly.
• Make note of light orientation.
• Remove (6) mounting screws to remove light.
• Unplug light.
Press to
Installation
• Plug in new light.
• Position new light in unit in same orientation as original light.
• Fasten new light in place with (6) new mounting screws.
• Reconnect power to unit.
F1617
Page 23
Page 24
CRRFTSMRN

LOCKING SYSTEM

Parts Replacement
Actuator rod
Lockbar
Sears, Roebuck and Co., Hoffman Estates, IL 60179, USA
F1618
Page 25
ACTUATOR ROD AND ACTUATOR CHANNEL REPLACEMENT
ACTUATOR ROD AND ACTUATOR CHANNEL REMOVAL
• Disconnect power from the unit.
• Remove work surface (Roll-away only).
• Remove pull out work surface (Roll­away only.) See drawer and work surface installation and removal.)
• Remove enough drawers to reach the top back inside of the unit. (See drawer and work surface installation and removal.)
• Push actuator rod to back of unit to disconnect from back of lock.
• Rotate actuator rod straight down.
• Pull out to remove.
ACTUATOR CHANNEL REMOVAL
• Move actuator channel fully to the right to remove from mounting flanges.
ACTUATOR CHANNEL INSTALLATION.
• Install slot in actuator channel over pin on lock bar. Move actuator channel fully to the right.
• Insert top flanges on actuator channel
into mounting flanges on inside top of
unit.
ACTUATOR ROD INSTALLATION
• Insert actuator rod into hole in actuator channel as shown.
• Insert back of actuator rod into actuator rod holder in top back of unit.
• Push actuator rod toward back of unit and line up with lock. Insert actuator rod into back of lock.
• Test lock operation.
• Reinstall drawers.
• Reconnect power to the unit.
Actuator rod to actuator channel
Page 26
ACTUATOR ROD BRACKET INSTALLATION AND REMOVAL
Removal
• Disconnect power from unit.
• For roll-aways, remove work surface. (See drawer and work surface installation and removal.
• Remove enough drawers to reach the top back inside of the unit. (See Drawer and Work surface installation and removal.)
• Remove top from unit. (See top installation and removal for your unit.)
• Pull actuator rod bracket forward. Lift out to remove.
Installation
• Insert actuator rod bracket into hole in back corner of unit. Ensure actuator rod bracket snaps into place. Note: The flexible tab should be in front.
• Reinstall top in unit.
• Push actuator rod toward back of unit and line up with lock. Insert actuator rod into back of lock.
• Test lock operation.
• Reinstall drawers.
• Reconnect power to the unit.
LOCK BAR INSTALLATION AND REMOVAL
Removal
• Disconnect power from the unit.
• For roll-aways, remove work surface. (See drawer and work surface installation and removal.
• Remove all drawers.
• Remove actuator rod and actuator channel. (See actuator rod and actuator channel installation and removal.)
• Remove top from unit.
• See top removal for your unit.
• Lift lock bar out through hole in top of unit.
Removal
• Insert lock bar through hole in top of unit.
• Slide lock bar down through lock bar guide.
• Reinstall top on unit.
• Reinstall actuator channel and actuator rod.
• Test lock operation.
• Reinstall drawers.
• Reconnect power to the unit.
Page 27
Tools Required:
Screwdriver, Crosstip
TOP INSTALLATION AND REMOVAL
ROLL-AWAYS, CHESTS WITHOUT TASK LIGHT
Removal
• Disconnect power from unit.
• For roll-aways, remove work surface, (See drawer and work surface installation and removal.
• Remove enough drawers to reach the top back inside of the unit. (See Drawer and Work surface installation and removal.)
• Remove lock retaining clip. Pull lock out to remove.
• Remove (4) screws holding top in place.
• For roll-aways, lift top off of unit enough to access the wiring harness. Disconnect wiring harness from unit.
• Remove top from unit.
Installation
• For roll-aways, connect the wiring harness to unit.
• Position top on unit. Attach using (4) screws.
• Position lock in unit. Install retaining clip to hold lock in place.
• Make sure the back of the actuator rod is inserted into the actuator rod holder in the back of the unit.
• Push the actuator rod toward the back of unit the and line up with lock. Insert
the actuator rod into the back of the
lock.
• Test lock operation.
• Reinstall drawers.
• Reinstall work surface.
• Reconnect power to the unit.
Page 28
CHEST TOP INSTALLATION AND REMOVAL
Tools Required:
3/8" Wrench
(With task light)
Chest Top Removal
• Disconnect power from unit.
• Remove enough drawers to reach the top back inside of the unit. {See
Drawer installation and removal.)
• Push actuator rod to back of unit to
disconnect from back of lock. Move actuator rod for access.
• Remove (4) screws holding top in
place.
• Lift top off of unit enough to reach the wiring harness.
• Disconnect wiring harness from unit.
• Remove top from unit.
Chest Top installation
• Connect wiring harness to top.
• Position top on unit.
• Attach using (4) screws.
• Make sure the back of the actuator rod is inserted into the actuator rod holder in the back of the unit.
• Push actuator rod toward back of unit and line up with lock. Insert the actuator rod into the back of the lock.
• Test lock operation.
• Reinstall drawers.
• Reconnect power to the unit.
Page 29
DRAWER AND WORK SURFACE INSTALLATION AND REMOVAL
Note: For pull out work surface without
task light, follow drawer removal
instructions.
DRAWER
• Empty the drawer.
• Fuliy extend the drawer.
Release
Lever Style - Lift or
ower (depending on the slide) the release lever
on both sides, (this
allows the slides to ride over the stops.) Pull out to remove.
Tab Style - Depress the
release tabs on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
To reinstall, carefully align the slides
and push the drawer into the unit until the drawer stops.
PULL OUT WORK SURFACE WITH
TASK LIGHT
Removal
• Disconnect the power from the unit.
• Remove enough drawers to gain access to connections in the back of
the roll-away behind the work surface.
Unplug work surface cord from back of
roll-away.
Remove and save back retaining clip.
Disconnect chain inside back of roll­away. (Move chain toward large round part of slot. Pull out to remove.)
Remove the work surface. (See drawer removal instructions.)
Retaining
To reinstall, carefully align the slides and push the work surface into the unit until the work surface stops.
Depress release tabs in back corners of the extendable work surface. Push the work surface into the unit to the fully retracted position.
Extend work surface far enough to gain access to connections in back. Connect chain inside back of roil away. (Insert chain into the large round part of the slot. Slide chain to small end of slot.)
Insert retaining clip to hold chain in place. Plug work surface cord into back of roll-away.
Reconnect power to the unit. (See: Connecting power.) Check work surface and task lighting for proper operation.
Reinstall drawers.
Page 30
CRRFTSMRN

LOCK REPLACEMENT

Removal
• Disconnect power from unit.
• For roll-aways, remove work surface. (See drawer and work surface installation and removal
• Remove enough drawers to reach the lock retaining clip behind the lock.
• Remove lock retaining clip. Pull lock out to remove.
Installation
• Position lock in unit. Install retaining clip to hold lock in place.
• Make sure the back of the actuator rod is inserted into the actuator rod holder in the back of the unit.
• Push actuator rod toward back of unit and line up with lock. Insert the actuator rod into the back of the lock.
• Test lock operation.
• Reinstall drawers.
Lock
Rekeying MASTERLOCK ONE­KEY™ lock
The MASTERLOCK® ONE-KEY™
learning lock system allows the chest and cabinet to be keyed alike. The lock can also be keyed to most house keys.
• Insert current key and turn lock to the right until access notch appears at top of lock,
• Depress and hold catch through access notch using re-keying tool provided.
• Remove key.
• Insert new key.
• Release catch
• Turn lock to center position,
• Remove key
Note: Catch must be depressed to insert or remove key in right hand position. Catch may be released between keys.
Access
Sears, Roebuck and Co., Hoffman Estates, IL 60179, USA
FI 623
Page 31
DRAWER AND WORK SURFACE INSTALLATION AND REMOVAL
Note: For pull out work surface without task light, follow drawer removal instructions.
DRAWER
• Empty the drawer.
• Fuliy extend the drawer.
Release
Lever Style - Lift or
ower (depending on the slide) the release lever on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
Tab Style - Depress the
release tabs on both sides, (this allows the slides to ride over the stops.) Pull out to remove.
To reinstall, carefully align the slides and push the drawer into the unit until the drawer stops.
PULL OUT WORK SURFACE WITH TASK LIGHT Removal
• Disconnect the power from the unit.
• Remove enough drawers to gain access to connections in the back of the roll-away behind the work surface.
Unplug work surface cord from back of
roll-away.
Remove and save back retaining clip.
Disconnect chain inside back of roll­away. (Move chain toward large round part of slot. Pull out to remove.)
Remove the work surface. (See drawer removal instructions.)
Retaining
To reinstall, carefully align the slides and push the work surface into the unit until the work surface stops.
Depress release tabs in back corners of the extendable work surface. Push the work surface into the unit to the fully retracted position.
Extend work surface far enough to gain access to connections in back. Connect chain inside back of roil away. (Insert chain into the large round part of the slot. Slide chain to small end of slot.)
Insert retaining clip to hold chain in place. Plug work surface cord into back of roll-away.
Reconnect power to the unit. (See: Connecting power.) Check work surface and task lighting for proper operation.
Reinstall drawers.
Page 32
Tools Required:
Screwdriver
CRRFTSMRN

STRIKER REPLACEMENT

Removal
• Remove drawer from unit.
• Turn drawer upside down.
• Depress (2) detents. Push striker in to remove.
Depress detents
Installation
• Turn drawer right side up.
• Position striker in drawer.
• Push striker toward back of drawer until striker snaps into place.
• Reinstall drawer.
Drawer installation and removal
• Empty the drawer.
• Fully extend the drawer.
Release
Lever Style - Lift or
lower (depending on the slide) the release lever on both sides, {this allows the slides to ride over the stops.) Pull out to remove.
Tab Style - Depress the
release tabs on both sides, {this allows the slides to ride over the stops.) Pull out to remove.
To reinstall, carefully align the slides and push the drawer into the unit until the drawer stops.
Sears, Roebuck and Co., Hoffman Estates, IL 60179, USA
FI 624
Page 33
Page 34

DRAWER FRONT REPLACEMENT

Tools Required:
Crosstip screwdriver
CRRFTSMRN
Removal
• Remove retaining screw(s).
• Slide drawer front assembly as indicated to unhook mounting tabs.
• Pull out to remove.
Installation
• Position drawer front on drawer assembly.
• Insert mounting tabs into notches on drawer.
• Slide drawer front over to attach.
• Install retaining screw(s) to hold drawer front in place.
Sears, Roebuck and Co., Hoffman Estates, IL 60179, USA
FI 625
Page 35
Loading...