Craftsman 50466 Owner’s Manual

Owner's Manual
CRRFTSMRN
Non-Contact High Temperature InfraRed
Thermometer
MODEL 50466
CAUTION: Read, understand and follow
Safety Rules and Operating
before using this product
© Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.craftsman.com 022205
Safety
Operation
Maintenance
EspaSoI
o]_I=lk'd=r:1:1 ill I IlVlVl:l :] :;:1_ili"
ONE YEAR FULL WARRANTY ON CRAFTSMAN Non-Contact High Temperature
InfraRed Thermometer If this CRAFTSMAN Non-Contact High Temperature InfraRed Thermometer fails to give
complete satisfaction within one year from the date of purchase, RETURN ITTO THE
NEAREST SEARS STORE OR OTHER CRAFTSMAN OUTLET IN THE UNITED
STATES, and Sears will replace it, free of charge.
If this CRAFTSMAN Non-Contact High Temperature InfraRed Thermometer is used for commercial or rental purposes, this warranty applies for 90 days from the date of purchase.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state
Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179
For Customer Assistance Call 9am-5 PM (EST) Monday through Friday 1-888-326-1006
__ & _ : o_,
USE EXTREME CAUTION when the laser pointer
beam is on DO NOT point the beam toward anyone's eye or allow
the beam to strike the eye from a reflective surface
DO NOT use the laser near explosive gases or in
other potentially explosive areas
"]"J:[o]I ;I[_:| i [o]_1_
Infrared Thermometer Specifications
Range / Resolution -58 to 1000°F (-50 to 538°C) / 0.1°C/F to 200 °
Accuracy + 2% of reading or + 4°F (2°C) whichever is greater.
Note: Accuracy is specified for the ambient temperature range: 64 to 82°F (18 to 28°C). Add +0.2°F!°F (+0.2°C!°C) outside this range.
Emissivity Field of View
Laser power Spectral response
General Specifications
Display Display rate Operating Temperature
Operating Humidity Power Supply
Automatic Power Off
Weight Size
0.95 fixed value DIS = Approx. 8:1 ratio (D = distance, S = spot)
Less than 1mW 6 to 14 !_m (wavelength)
Backlit LCD display with function indicators 1 second (approx.) 32°F to 122°F (0°C to 50°C)
Max. 80% RH
9V battery
Meter shuts off automatically after 6 seconds
6.35 oz. ! 180g
3.2 x 1.6 x 6.3" (82 x 42 x 160mm)
[o[o]_i i _{o]IF.'_
1. Laser Pointer
2. InfraRed Sensor
3. Measure Trigger
4. Battery compartment
5. LCD display
6. Function buttons
7. Handle Grip
O" __* _. _. _ O_.
1. Hold the meter by its Handle Grip and point it toward the surface to be measured.
2. Pull and hold the red Trigger to turn the meter on and begin testing. The temperature reading, the 'SCAN' icon, the emissivity icon (E=0.95), and the unit of measure will appear. Note: Replace the battery if the display does not light.
3. While continuing to pull the Trigger: a. Push the laser button Z_to turn on the laser pointer. When the laser is ON the
laser iconz_will appear on the LCD over the temperature reading. Aim the red beam approximately a half inch above the point of test (pressing the laser button
again turns the laser off).
b. Select the temperature units using the °C or °F button.
c. Push the backlight button _ to turn on the LCD backlighting function.
4. Release the Trigger and the reading will hold for approximately 6 seconds (HOLD will appear on the LCD) and then the meter will automatically shut off.
q
_11_1IIIm][o)Ivj I_vl!
The meter's field of view is 8:1. For example, if the meter is 16 inches from the target (spot), the diameter of the target must be at least 2 inches. Other distance ratios are shown below in the field of view diagram.
Note that measurements should normally be made less than 2 feet from the target. The meter can measure from further distances but the measurement may be affected by external sources of light. In addition, the spot size may be so large that it encompasses
surface areas not intended to be measured.
Diameter of Spot
4 _
.................. 16"-- -"
e
- ......................... 32,,= ==,
e m
m
Distance to Object