Operation
Installation
Service
Repair Parts
CONTENTS
Introduction ........................................................................ 2
Warranty .............................................................................. 2
Safe ta.' Rules .......................................................................... 2
lnstallatitm ........................................................................ 3-.5
Service ............................................................................... "3
Please read our inslrLtclions bclbre you install and tlSC \'t)tlr
uew ptuula{ this will help yt)u obtain hill value ;rod good scr
vice from it. It will also help you avoid needless serx'icc costs
that restilt from CatlSCS we calnlOt COlltl-Ol dnd canllOl Cover
i11 O(IF \varrlllU}
INTRODUCTION
Repair Parts ....................................................................... (,-7
LIMITED LIFETIME WARRANTY on CRAFTSMAN ®PROFESSIONAL 1/2-HP PEDESTAL SUMP PUMP
Provided that it is installed and operated according to the instructions in the owner's manual, if this pump ever fails for the original purchaser due to a defect in material or workmanship, return it to your nearest Sears store, and Sears will replace it free ff charge You pay for labor if you
choose to have Sears install the replacement pump.
FULL ONE YEAR WARRANTY ON CRAFTSMAN ® 1/3-HP PEDESTAL SUMP PUMP
For one year from the date of purchase, Sears will repair or replace this sump pump, free of charge, if defective in material or workmanship, This warranty does not cover repairs or replacement parts necessary because of abuse or negligence including failure to install, adjust and operate
this pump accordin@ to the instructions in the owner's manual.
Warranty service is available by Calling Sears at 1-800-4-MY-HOME _.
LIABILITY LIMITATION
Sears is not liable for loss or damage to property, nor for any incidental or consequential loss or expense from property damage, that results di rectly or indirectly from the use of this p_uct. Some states do not allow the exclusion or limitation of properly, incidental or consequential
damages, so the above limitation or exd0M0n may not apply to you.
This warranty applies only wlille this pm_luct is used in the United States. This warranty gives you specifie legal rights, and you may also have other rights which vat), from state to state.
Sears, RQebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179
RULES FOR SAFE INSTALLATION AND OPERATION
Carefully read and follow all safety instructions in this 1 Read these Instructions and Safety Rules carefully.
manual or on pump.
A
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for per- sonal injury!
_ warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
[_WARNING_ warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
[A CAUTION ] warns about hazards that will or can cause
minor personal injury or property damage if ignored. The word NOTICE indicates special instructions which are
important but not related to hazards. Electrically powered sump pumps normally give many years
of trouble-free service when correctly installed, maintained, and used. However, unusual circumstances (interruption of power to the pump, dirt/debris in the sump, flooding that ex- ceeds the pump's capacity, electrical or mechanical failure in the pump, etc.) may prevent your pump from functioning normally. To prevent possible water damage due to flooding, consult your local Sears store about installing a secondary sump pump or a DC backup sump pump. See "Service", Page 5, for information about common sump pump prob-
lems and remedies. NOTICE: This unit is not designed for applications involving
salt water or brine! Use with salt water or brine will void
warranty.
Failure to lollow them could cause serious bodily injuD.' and/or property damage.
2.
Check your local Electrical and Plumbing Codes before installing pump. You must comply with their rules,
[AWARNING] Do not use in explosive atmospheres.
Pump water only with this pump.
Do not touch an operating motor. Modern motors arc de- signed m run at high temperatures.
[AWARNING]Risk of electric shock. Proceed as fol- lows if pump needs servicing: A. Disconnect power to pump outlet box before
pulling pump cord plug! After plug is pulled, let pump cool for 20 minutes before attempting to work
on it.
B. Take extreme care when changing fuses. To re-
duce the chance of fatal electrical shocks, DO NOT stand in water or put your finger in the fuse socket.
C. Ground the electrical outlet box.
D. Use only a grounded outlet for cord plug. E. Do not handle pump motor with wet hands or when
standing on wet or damp surface, or in water.
3,
Never run pump dry. To do so can damage internal parts, overheat the pump (which can cause burns to people han- dling or servicing the pump), and will w)id the warnmty!
WARNIN_ FIRE HAZARD- Do not store or rest ob-
jects on or near motor or switch linkage. Keep all flammable objects or liquids away from motor.
2
4 This punlp is reconlnl(-nded |])r use in permanent instal-
lations Ol__ly. Do not it_istal[ or1 clay, earth, or sand surfaces
J_.CAUTION i Punq) must bc level (column most be verti-
cal) when operating. If motor is tilted, internal start/run
switch lilly overheat and daluage i11otor.
ADDITIONAL INSTALLATION
MATERIALS
Sump/Utility Puml_ Hose Kit, SEARS Stock No. 27909, con- taioing 24' of 1-1/4" flexible plastic pipe, a 1-1/4" plastic
adapter and a stainless steel clamp. Cbeck Valve, SEARSStock No. 2789 or 2792.
THE SUMP
Tbe sump should be located at tile lowest place in tim base- ment or area to be drained. Floor drains from other areas in
the basement may bc tiled into tile sump. Drain tile around a house foundation can also be tiled into the sump, effec-
tively removing water and relieving pressure from this area. A suitable sump can be a 2(1" or 24" sewer tile. Sump must
be at least 12" in diameter.
A sump cover is desirable to exclude refuse from the sump. Consult local code for sump cover specifications.
SPECIFICATIONS
Power supply required .................................... 115V, 60 HZ.
Horsepower (390.303302) ............................................. 1/3
Horsepower (390.303491) ............................................. 1/2
Motor duty ......................................................... Intermittent
Liquid Temp. Range ........................ 32 ° F to 70 ° F (0°-21°C)
Individual Branch Circuit
Requirement GFCI Class A ...................................... 15 Amps
Motor full load (maximum - 390.3(13302) ............. 3.5 Amps
Motor full load (maximum - 390.303491) ............ 7.3 Amps
Discharge (390.303302) ...................................... 1-1/4" NPT
_iscbarge (390.303491) ...................................... 1-1/2" NPT
PUMP INSTALLATION
Check your local Electrical and Plumbing ('odes before in- stalling pump. You nlust comply with their rules.
Set tile pump on the bottom of the stlnlp, luakiug sure that
it sits solidly and is level. Be sure there is cnotlgh space
arottlld the punlp to allow tile s\vitc]l I'ree MOVelncnt as
tile stlnlp veater level cllallgCS I)o not Jllstall un clay,
earth, or salld
_" CAUTION Risk of flooding. If a flexible discharge
hose is used, pump may move around in sump
when motor starts. If it moves far enough so that the switcb bits the side of the sump, the switch may stick and
prevent pump fi'om starting. Make sure that pump is se-
cured so tbat it cannot "walk around" in sump.
NOTE: To avoid backflow into tile sump when the pump shuts off, install a Check Valve, SEARSStock No. 2789, in the
threaded discharge port of pump (390.303302) or l-1/2"xl-
1/4" reducer bushing (390.303491 ). Reducer bushing is in-
cluded with Model 390.303491. Be sure arrow on check valve body points away from the pump. This Check Valve is
equipped with an air bleed hole to prevent airlocking the pump. If using any other check valve, drill 1/8" (3.2 ram) hole in discharge pipe just above pump body but below check valve to prevent air locks.
Use 1-1/4" plastic pipe from Hose Kit No. 27909 for the dis- charge pipe. Run the discharge pipe to the nearest sewer outlet or other point of disposal. Use the most direct route with the fewest turns and elbows possible.
Use Teflon tape to seal threads in plastic pipe. Hand tighten only.
SumpCover
BasementFloor
1/4"
!
_ Sewer Tile
12'Min
' ' ' ';; Concrete
/
Figure I