RULES FOR SAFE INSTALLATION AND OPERATION
Carefully read and follow all safety instructions ill this
manual or on pump.
WARNING
_L Pump is supplied with
3-conductor grounding
type cord. Connect only to
_This is the safety alert symbol. WJlcll yotl scc this
sylnI_oJ Oll }our punll_ or in this inantlal, look for one
of tile ti)llowing signal words and be alert to the potential
ior personal injut3'!
_=_'_ DANGER warns ahout hazards that will cause
serious personal injury, death or major prop-
erty damage if ignored.
I&WARNING1WARNING warns about hazards that can
z cause serious personal injury, death or major
property dalnage if ignored.
_k CAUTION ]CAUTION warns about hazards that will or
can canse minor personal injury or property
damage if ignored.
The word NOTICE indicates special instructions which are
important but not related to hazards.
1. To avoid risk of serious bodily injury and property dam-
Hazardous voltage.
Can shock, burn,
or cause death.
Ground pump before
connecting to
power supply.
allow any part of cord or receptacle ends to sit in
water or damp locations.
_IL Unplug pump before servicing.
properly grounded, GFCI
protected outlet. Do not lilt
pump by electrical cord.
_Pump is non-sub-
mersible. Keep motor
dry at all times. Do not wash
motor. Do not inlmerse. Pro-
tect motor from wet weather.
_usingextension cord,
use only UL approved
indoor/outdoor, 3-wire,
grounding typecord. Do not
age, read safety instructions carefully before installing
pump.
2. Follow local and/or national plumbing and electrical
codes when installing pump.
3. _]To avoid fatal shocks, proceed as fol-
lows if pump needs servicing:
A Disconnect power to pump outlet box before
pulling pump cord plug. After plug is pulled, let
pump cool for 20 minutes before attempting to work
on it.
B. Take extreme care when changing fuses. To re-
duce chance of fatal electrical shocks, DO NOT stand
in water or put your finger in the fuse socket.
C. Ground electrical outlet box.
D.Use only Ground Fault Circuit Interrupter (GFCI)
protected grounded outlet for cord plug.
4. Never run pump dry. To do so can damage internal
parts, overheat pump (which can cause burns to people
handling or servicing pump), and will void warranty!
5. [_ WARNING ]Risk of fire or explosion. Do not pump
gasoline or any other flammable liquids with pump. Do
not use pump in atmosphere that might contain
flammable fumes or vapors.
6. Do not pump chemicals or corrosive liquids witb pump.
FULL ONE YEAR WARRANTY ON CRAFTSMAN ® 112-HP UTILITY/SPRINKLER PUMP
For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective in material or
workmanship.
SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL LOSS OR
EXPENSE FROM PROPERTY DAMAGE DUE DIRECTLY OR IND1RECTL Y FROM THE USE OF THIS PRODUCT
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion
may not apply to you.
WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPARTMENT IN THE
UNITED STATES.
This warranty applies only while this product is in the United States.
This warranty gives you specific legal rights, and you may also have other fights which vary from state to state.
Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179
LIMITATION OF LIABILITY
_,WARNING ] Hazardous pressure. Pump body may ex-
plode if used as a booster pump unless re-
lief valve capable of passing full pump flow at 75 PSi
(517 kPa) is installed.
_WARNING1 Explosion hazard. Never run pump with
Joutlet shut off or blocked. If water is
trapped in pump during operation, it may turn to
steam, leading to explosion and burns.
NOTICE
Pump clean water only with pump. To avoid clogging
pump and damage to shaft seal, do not pump water con-
taining solids, foreign material, sand, silt, or abrasives.
Always have suction strainer installed when pump is oper-
ating. Failure to use strainer may cause pump failure and
void warrant3'.
Clean strainer and flush out pump after each use.
Make sure all hose and pipe connections in suction line are
tight. An air leak in suction line will prevent proper priming
and reduce performance
To prevent damage to pump materials, do not use pipe joint
compounds on pump ports. Use only teflon tape or Plasto-
Joint-Stik* to seal threads.
Tighten all piping joints to pump hand tight +1-1/2 tums only.
Overtightening may break pump and will void warranty.
This unit is not designed for applications involving salt water
or brine! Use with salt water or brine will void warranty.
*Lake Chemical Co., Chicago, Illinois
INSTALLATION
Pumping From Lakes, Streams, and Ponds
Locate pump as near as possible (vertically) to water source,
fn kee l) suction lilt (distance from water to punlp) as low as
possible. Place punq_ on level Sul_port. I'rotecl against ex-
cess moisture and Ilooding
lxmg pipe runs ;rod many litting_ increase friction and re-
duce flow. Use the smallest possible number of fittings and
the shortest possible nm for piping.
Support weight of pipe
[k" sure water is clear of debris wllieh can dog ptmlp, such
as sand, dirt, or scale, l:_esure fl)ot valve and hose are clean
and in good condition; scale or dirt in f_)ot valve can cause
valve to leak. Valve leakage may cause pump to lose prime,
which can result in pump failure
Piping
Both snction and discharge ports arc tapped for 1" NPT
(National Pipe Thread) threads. If using hoses, use hose
adapters. When pumping from lakes, streams or ponds, use
reinforced hose supplied with pump. Ordinary garden hose
will collapse and cause pump failure. Keep strainer with l_)ot
valve on end of suction hose. Inspect and clean strainer fre-
quently (Figure 1).
NOTICE: An air leak in suction pipe may draw air in al-
though no water leaks ()tit. Make sure there arc no air leaks
or air pockets in suction pipe.
Boosting City Water Pressure
_l, CAUTION i Hazardous pressure. When using garden
lame as a disch3rgc line, do not rl.lllr*tlnlp with
]lose OtltJct or nozzle dosed Ilose or IIOZZ]e I11ay [_tlt'St frolll
cxcessi_ c presstlrc. Whcll tlsillg ptllllp its it high-pressure
washer, use only reinhn'ced high pressure hose or pipe for
disch:u\tge line. When using garden hose. install adapters to
pump suction and discharge. Suction hose will require two
h'male ends, Either I.ISC it standard washhlg machitle supply
hose or modify a short piece of standard 3/4" garden hose
as a suction line (see Figures 2A and 2B).
(AHIlleCt Stlction hose to tkttlCet on outside of house (see
Figure 3, Page 4) and to ptnllp sttction Use 3/4" standard
garden hose fi_r discharge. Pump can supply up to 3 sprin-
klers (depending on GPM output of sprinklers).
115 volt, GFClprote_ed,
grounded outlet box.
2374 0396
Foot valve with strainer
(Supplied - clean frequently)
Figure I - Typical Installation
Discharge Line
(Garden Hose or
Rigid Pipe)
plastic pipe adapter
Suction Line
supplied)
Figure 2A - When using pump as a booster pump
with hose-connected suction and discharge,
install adapters to pump suction and discharge
ports.
Hose adapter or
Priming Plug
2376 0396
Figure 2B - Connect pump to spigot for use
with sprinklers. Connect with adapters supplied
with pump.