RBT2
Product Guide
Run-Back Timer
Overview
The RBT2 run back timer is a high output electronic timer which provides control
for a wide range of loads. The unit allows an appliance to be powered for a set
time period which can be adjusted by the user. A simple LED display shows the
user how much time is left to run, and its “Night Light” feature illuminates all the
LED’s when the unit is not in use, so the unit can be located in the dark. Pressing
the switch whilst the unit is operating allows the user to cancel the timing program,
and the memory function of the timer will remember the last time period selected.
To operate the unit, follow these steps:
1. Press the button to start the timing sequence - the last selected time
period will be used.
2. As the unit times out the position of the LED will change to show how
much time is left. The LED will give a warning flash when 2 minutes are
left on the timing sequence.
3. Pressing the button again during timing will turn the unit off.
4. Press and hold the button to set the desired time period (15 minutes; 30
minutes; 1 hour or 2 hours). The LED will illuminate next to the selected
time. After holding the button for a few seconds the timing will change to
the next time period available. Release the button when it illuminates next
to the desired time period — the LED will stay on the selected time.
5. When the unit has turned off, it is not necessary to select the time period
again, just press the button to repeat the previous time period.
LOAD 16 Amp resistive load
6 Amp fluorescent lighting
3 Amp compact fluorescent lighting
3 Amp low energy lighting
3 Amp low voltage lighting
Fluorescent lighting
SUPPLY VOLTAGE 220-240 Volts AC 50 Hz
TIME OUT PERIOD 15 minutes; 30 minutes; 1 hour or 2 hours
(selectable)
(including immersion heaters)
(switch primary of transformer)
(max 6 fittings recommended)
Installation
Warning. This device works at mains potential. Be sure to take care when working
with electricity.
1. Make sure the load is connected and in working order.
2. If fitting to a metal back box ensure that top and bottom lugs are removed.
3. Isolate the mains supply to the circuit at the main consumer unit.
4. Connect the controller via the terminal block. Live supply to the L terminal,
the load to the LIVE OUT terminal and neutral to the N terminal.
5. Screw the unit to the wall and switch the mains supply back on at the distribution board.
Specification
FIXING METHOD Surface fixing 16mm deep plastic surface mount
moulded box.
Flush fixing 16mm deep steel wall box or
20mm deep c avity wall box.
CONTACTS Microgap µ
TERMINAL CAPACITY 4.0mm2
MATERIAL Flame retardant ABS
TYPE Class 2
TEMPERATURE -10°C to 35°C
CONFORMITY EMC-2004/108/EC
LVD-2006/95/EC
IMPORTANT NOTICE!
This device should be installed by a qualified electrician in
accordance with the latest edition of the IEE Wiring
Regulations and any applicable Building Regulations.
Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior notice.