CP Electronics RBT1 User Manual

RBT1 Product Guide
Run-Back Timer
Overview
The RBT1 run back timer is a high output electronic timer which provides control for a wide range of loads. Its powerful 20A output makes it particularly suitable for the control of immersion heaters. The unit allows an appliance to be powered for a set time period which can be adjusted by the user. A simple display shows the user how much time is left to run. An ON/OFF switch allows the user to cancel the timing program whilst a memory remembers the last timing sequence selected.
To operate the unit, follow these steps:
1. Press and release the TIME button to select the desired time period. The LED will flash next to the selected time.
2. Press the ON/OFF button to startthe LED will stay on next to the se­lected time.
3. As the unit times out the position of the LED will drop down to show how much time is left.
4. Pressing the ON/OFF button during timing will turn the unit off.
5. At any stage during timing, pressing the TIME button will set a new time period.
6. When the unit has turned off, it is not necessary to select the time period again, just press the ON/OFF to repeat the previous time period.
Warning. This device works at mains potential. Be sure to take care when working with electricity.
1. Make sure the load is connected and in working order.
2. If fitting to a metal back box ensure that top and bottom lugs are removed.
3. Isolate the mains supply to the circuit at the main consumer unit.
4. Connect the controller via the terminal block. Live supply to the L terminal,
5. Screw the unit to the wall and switch the mains supply back on at the distri-
LOAD 20 Amp resistive load (including immersion heaters) 6 Amp fluorescent lighting 3 Amp compact fluorescent lighting 3 Amp low energy lighting 3 Amp low voltage lighting (switch primary of transformer) Fluorescent lighting (max 6 fittings recommended)
Installation
the load to the LIVE OUT terminal and neutral to the N terminal.
bution board.
Specification
moulded box.
Flush fixing 25mm steel wall box or 32mm
deep cavity wall box.
CONTACTS Microgap µ TERMINAL CAPACITY 4.0mm2 MATERIAL Flame retardant ABS TYPE Class 2 TEMPERATURE -10°C to 35°C CONFORMITY EMC-2004/108/EC
LVD-2006/95/EC
IMPORTANT NOTICE!
This device should be installed by a qualified electrician in accordance with the latest edition of the IEE Wiring Regulations and any applicable Building Regulations.
Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior notice.
C.P. Electronics Ltd
Brent Crescent London NW10 7XR United Kingdom Tel: + 44 (0) 333 900 0671 Fax: + 44 (0) 333 900 0674 www.green-iswitches.co.uk enquiry@green-iswitches.co.uk
Ref: #WD142 Issue 4