The RBT1 run back timer is a high output electronic timer which provides control for
a wide range of loads. Its powerful 20A output makes it particularly suitable for the
control of immersion heaters. The unit allows an appliance to be powered for a set
time period which can be adjusted by the user. A simple display shows the user
how much time is left to run. An ON/OFF switch allows the user to cancel the timing
program whilst a memory remembers the last timing sequence selected.
To operate the unit, follow these steps:
1. Press and release the TIME button to select the desired time period. The
LED will flash next to the selected time.
2. Press the ON/OFF button to start—the LED will stay on next to the selected time.
3. As the unit times out the position of the LED will drop down to show how
much time is left.
4. Pressing the ON/OFF button during timing will turn the unit off.
5. At any stage during timing, pressing the TIME button will set a new time
period.
6. When the unit has turned off, it is not necessary to select the time period
again, just press the ON/OFF to repeat the previous time period.
Warning. This device works at mains potential. Be sure to take care when working
with electricity.
1. Make sure the load is connected and in working order.
2. If fitting to a metal back box ensure that top and bottom lugs are removed.
3. Isolate the mains supply to the circuit at the main consumer unit.
4. Connect the controller via the terminal block. Live supply to the L terminal,
5. Screw the unit to the wall and switch the mains supply back on at the distri-
LOAD 20 Amp resistive load
(including immersion heaters)
6 Amp fluorescent lighting
3 Amp compact fluorescent lighting
3 Amp low energy lighting
3 Amp low voltage lighting
(switch primary of transformer)
Fluorescent lighting (max 6 fittings recommended)
SUPPLY VOLTAGE 220-240 Volts AC 50 Hz
TIME OUT PERIOD 15 minutes to 2 hours in 15 minute increments
FIXING METHOD Surface fixing 25mm deep plastic surface mount
Installation
the load to the LIVE OUT terminal and neutral to the N terminal.
bution board.
Specification
moulded box.
Flush fixing 25mm steel wall box or 32mm
deep cavity wall box.
CONTACTS Microgap µ
TERMINAL CAPACITY 4.0mm2
MATERIAL Flame retardant ABS
TYPE Class 2
TEMPERATURE -10°C to 35°C
CONFORMITY EMC-2004/108/EC
LVD-2006/95/EC
IMPORTANT NOTICE!
This device should be installed by a qualified electrician in
accordance with the latest edition of the IEE Wiring
Regulations and any applicable Building Regulations.
Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior notice.
C.P. Electronics Ltd
Brent Crescent
London
NW10 7XR
United Kingdom
Tel: + 44 (0) 333 900 0671
Fax: + 44 (0) 333 900 0674
www.green-iswitches.co.uk
enquiry@green-iswitches.co.uk
Ref: #WD142 Issue 4