Coyote C1SBLP Installations Instructions

C1SB INSTALL GUIDE
DIMENSIONAL RENDERINGS
16 3/4"
11"
15 1/4"
Overall Product Dimensions
Model No. Height Width Depth
15,000 15,000
11 3/8"
15 1/4"
1/2" Female Pipe
17"
16 3/4"
11" .5 PSI No Electrical Connections Required 4" .5 PSI No Electrical Connections Required
C1SB
CJAKTC1SB
Model No. Gas Supply BTU's Regulator WC Pressure Max PSI Electrical Requirements
C1SBLP Propane C1SBNG Natural Gas
Important Note to Installer: This file is not intended to replace your Owners' Manual which contains specific safety requirements
and consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in side burner.
13"
11"
11"
13 3/4"
Cutout Dimensions for Island
Model No. Height Width Depth
C1SB
CJAKTC1DB
10 1/4"
11"
10 1/8"
13 3/4"
16"
13 5/8"
16"
www.coyoteoutdoor.com
C1SB INSTALL GUIDE
NON-COMBUSTIBLE CONSTRUCTION ONLY
Insulated Jacket NOT Required
3
/4
"
SIDE
BURNER
3"
OPENING
3"
3"
24"
COUNTERTOP
OVERHANG
1 1/2" MIN
24"
13 5/8"
24"
INCLUDING
COUNTERTOP
10 1/4"
OPENING
HEIGHT
TOP VIEW
10 1/8"
CUTOUT
WIDTH
COMBUSTIBLE CON
Insulated Jacket Required
TOP VIEW
16"
INCLUDING
COUNTERTOP
11"
OPENING
HEIGHT
13 3/4"
CUTOUT
WIDTH
STRUCTION
Model # CJAKTC1SB
7/8"
SIDE
BURNER
OPENING
COUNTERTOP
OVERHANG
3"
3"
3"
1 1/2" MIN
DOORS / DRAWERS
OPENING WIDTH
FRONT VIEW
OPENING
HEIGHT
Combustible material can not be within 24" of the side
burners
frame
This applies to all directions - horizontal & verticalShaded area above on "TOP VIEW" illustrates the 24"
minimum requirement (not to scale for rendering purposes)
The grill is designed
to hang from
the counter top with no
DOORS / DRAWERS
OPENING WIDTH
FRONT VIEW
If using combustible material within 24" of the grill frame,
you MUST use the corresponding Coyote Insulated Jacket
Using a insulated jacket, does not waive any other standard
installation procedure (ventilation, connections, etc)
The jacket is designed to hang from the counter top with no
support underneath
OPENING
HEIGHT
support underneath
Ventilation Requirements:
Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within the island.These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.For a propane setup, the vents should be installed lower as propane is heavier than air.For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.Do not locate the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped gas to dissipate.
Important Note to Installer: This file is not intended to replace your Owners' Manual which contains specific safety requirements and
consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in side burner.
www.coyoteoutdoor.com