C1PB INSTALL GUIDE
DIMENSIONAL RENDERINGS
24 7/8"
22 3/4"
11"
Overall Product Dimensions
Model No. Height Width Depth
24 7/8"
60,000 60,000
24"
24 1/4"
22 3/4"
1/2" Female Pipe
C1PB
CJAKTC1PB
Model No. Gas Supply BTU's Regulator WC Pressure Max PSI Electrical Requirements
C1PBLP Propane C1PBNG Natural Gas
13"
11"
22 1/8"
11"
Cutout Dimensions for Island
Model No. Height Width Depth
C1PB
CJAKTC1PB
11" .5 PSI No Electrical Connections Required 4" .5 PSI No Electrical Connections Required
10 1/4"
11"
21"
22 1/8"
21"
21 7/8"
Important Note to Installer: This file is not intended to replace your Owners' Manual which contains specific safety requirements
and consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in side burner.
www.coyoteoutdoor.com
C1PB INSTALL GUIDE
NON-COMBUSTIBLE CONSTRUCTION ONLY
Insulated Jacket NOT Required
3
/4
"
SIDE
BURNER
OPENING
4"
COUNTERTOP
OVERHANG
4"
24"
1 1/2" MIN
4"
INCLUDING
COUNTERTOP
10 1/4"
OPENING
HEIGHT
24"
24"
21"
TOP VIEW
21"
CUTOUT WIDTH
21"
CUTOUT WIDTH
COMBUSTIBLE CONSTRUCTION
Insulated Jacket Required
24"
21 7/8"
CUTOUT WIDTH
24"
INCLUDING
COUNTERTOP
11"
OPENING
HEIGHT
CUTOUT WIDTH
Model # CJAKTC1PB
SIDE
BURNER
TOP VIEW
22 1/8"
22 1/8"
OPENING
4"
4"
4"
7/8"
COUNTERTOP
OVERHANG
24"
1 1/2" MIN
DOORS / DRAWERS
OPENING WIDTH
OPENING
HEIGHT
FRONT VIEW
Combustible material can not be within 24" of the grills
frame
This applies to
all directions - horizontal & vertical
Shaded area above on "TOP VIEW" illustrates the 24"
minimum requirement (not to scale for rendering purposes)
DOORS / DRAWERS
OPENING WIDTH
FRONT VIEW
If using combustible material within 24" of the grill frame,
you MUST use the corresponding
Coyote Insulated Jacket
Using a insulated jacket, does not waive any other standard
installation procedure (ventilation, connections, etc)
The jacket is designed to hang from the counter top with no
support underneath
OPENING
HEIGHT
The grill is designed to hang from the counter top with no
support underneath
Ventilation Requirements:
Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within the island.These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.For a propane setup, the vents should be installed lower as propane is heavier than air.For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.Do not locate
the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped gas to dissipate.