Coway MHS-E5010X User Manual

Looks Good Easy Smart
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지1
EnglishEnglish
Website:http://www.coway-usa.com
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지2
Greetings / Precaution
Thanks for purchasing Coway humidifier. To use and maintain your product correctly, read and retain this manual carefully for future reference. Refer to this manual if any function of your product does not operate normally or if a problem occurs while using your product. Woongjin Cuchen is not liable for any damage caused by not following the instructions in this manual.
Dear Customers
Important safety instructions
22 23
02
09 10 11 16 19
Parts descriptions
Display LED / Control Panel
Direction for use
Control panel instruction
Maintenance
Troubleshooting guide
Appliance specifications
Precaution
How to use
Troubleshooting
Features
07
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지3
Precaution
How to use
Troubleshooting
Precaution
Instructions to protect owner’s safety and prevent property damage. Please read and save all instructions before use.
Warning
Caution
For the Power
Important safety instructions
Death or critical damage is possible if the instructions are not followed.
Danger
Considerable injury or property damage is possible if the instructions are not followed.
Minor injury or property damage is possible if the instructions are not followed.
Danger
This appliance is only
for 120 V~.
Danger of electric shock or fire.
Do not use a damaged power cord or loose outlet.
Do not move your appliance by pulling the power line.
Danger of electric shock or fire.
Do not touch power cord with wet hands.
Danger of electric shock or fire.
Remove foreign materials from the power cord.
Danger of failure,fire or electric shock.
Do not connect or alter the power cord on your own authority.
Danger of electric shock.
Danger of electric shock or fire.
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지4
Precaution
03/04
For the Power
Precaution
Instructions to protect owner’s safety and prevent property damage. Please read and save all instructions before use.
Danger
Do not plug and unplug the power cord continuously.
Danger of electric shock or fire.
If the power cord is damaged, have it replaced or repaired by its manufacturer, dealer or a qualified technician (service staff).
Danger of electric shock or fire.
Make sure that the power cord is unplugged when repairing, checking or cleaning the appliance replacing a part.
Danger of electric shock.
Unplug the power cord by pulling the cord.
If you unplug it by pulling the power cord,part of the core line may be disconnected and consequently heat or fire may be generated.
Do not plug several electric appliances in one outlet simultaneously. Use a dedicated outlet.
Danger of heating, ignition, electric shock or fire.
If water enters the power part, unplug the power cord and dry it completely before use.
Danger of electric shock or fire.
Do not bend the power cord by force or allow it to be crushed or damaged by heavy objects.
Danger of electric shock or fire.
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지5
Precaution
How to use
Troubleshooting
For installation
Warning
Keep the appliance out of reach of children.
Failure to do so may cause fire, electric shock or burning.
Do not use a damaged water tank.
Doing so may cause fire, electric shock or leakage.
Do not use the appliance on glass.
If the glass surface gets wet with water the appliance will slide on the glass and may be damaged or you may get burned.
Avoid direct sunlight and avoid installing the appliance near thermal appliances or putting candles or cigarettes on the appliance.
Doing so may cause fire.
Do not install the appliance in a humid, dusty or wet place.
Doing so may cause electric shock or fire.
Do not install on a slope and do not knock or bang the appliance.
Doing so may cause bodily injury, property damage or leakage.
Do not install the appliance close to a wall.
Keep a clear distance of 3.9”(10 cm) from a wall and
39.4”(100 cm) from the top.
Avoid humidifier's mist from directly contacting furniture, TV, gas range, etc.
According to water quality white powder may accumulate on surrounding furniture or TV due to calcium or magnesium dissolved in the water and the flame of the gas range may be affected.
Avoid your legs, hands or other objects from tripping on the power cord and the appliance from falling.
Doing so may cause bodily injury, property damage and leakage.
Do not install the appliance on a home appliance such as a TV.
The home appliance may be damaged by the mist.
Caution
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지6
Precaution
Precaution
05/06
In use
Instructions to protect owner’s safety and prevent property damage. Please read and save all instructions before use.
Danger
Do not put pins, needles or foreign objects into the mist outlet of the humidifier and the seam of the appliance.
Doing so may cause bodily injury by electronic shock or abnormal operation.
Do not disassemble the mist outlet, while operating and especially, prevent children from touching it with their hands or faces.
Doing so may cause injuries or burns.
Supply clean water with normal temperature (between 42.8 (6℃) and 95℉(35)) to the water tank.
Failure to do so may cause damage of the appliance or nebulizer.
Do not block the mist outlet with a towel or hand while operating the appliance.
Doing so may cause appliance failure, fire, burn orleakage.
Do not disassemble the tank or transport the appliance while operating.
Do not scratch the nebulizer surface with fingers or a sharp implement.
Do not apply strong impact while transporting the water tank for top-up or cleaning.
Doing so may cause appliance malfunction.
Doing so may cause appliance malfunction, electric shock, leakage, fire or burn.
Doing so may cause leakage or appliance damage by the impact and dropping the tank may cause injury on the instep of a foot or other body part.
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지7
Precaution
How to use
Troubleshooting
Do not directly inhale the humidity.
Doing so may damage your health.
Do not leave volatile materials (insecticide, gasoline, thinner, benzene, etc.) on top of or near the appliance.
Doing so may cause deterioration, discoloration and fire.
Warning
Danger
Caution
If the product is not to be used for a long time, remove the water in the reservoir or water tank thoroughly before storing.
The remaining water may cause nebulizer damage, malfunction or pollution.
The use of organic solvents may cause deterioration, discoloration or bodily injury.
Do not disassemble, repair or tamper with the appliance arbitrarily.
Doing so may cause electric shock, fire or
appliance damage.
Do not allow a child to use the appliance by itself. Keep the appliance out of the reach of children.
Doing so may cause electric shock, burn or bodily injury.
Do not open and close the water tank lid repeatedly.
The spray may become weak or stop due to the increased water level in the reservoir and water leakage may cause appliance failure or fire.
Do not intentionally press the load with a chopstick or other tools.
The spray may become weak or stop due to the increased water level in the reservoir and water leakage may cause appliance failure or fire.
Do not use organic solvents such as spray-type insecticide, gasoline, thinner and benzene to clean the appliance.
Failure to do so may cause electric shock or appliance damage.
When draining for appliance cleaning, incline the appliance in the drain direction to avoid the water from being entered the vent.Wait until the water gets cold before draining.
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지8
Precaution
Features
With 2-way mist outlet, bidirectional spray is available and minute water particles are sprayed to prevent the area near the humidifier from becoming wet.
Top Water
Pouring Structure
STERILIZE
PROGRAM
SLEEP
HEALTHHEALTHHEALTH
WA
TER
4-Step
CHILD
󱎷 2-Way Mist Outlet
By considering the top water pouring structure, water tank is not dispatched from the main body and the water is topped up through the upper water filter of the water tank for user convenience.
Top WaterTop Water
Pouring StructurePouring Structure
Top Water
Pouring Structure
󱎲 Top Water Pouring Structure
Using ion exchange resin removes hardness materials such as calcium and magnesium from water and using iodinated resin improves antibacterial activity.
Top Water
Pouring Structure
WA
TER
󱎳 Iodine Filter
The filter sucks the exterior air of the purifier and purifies it into clean air.
Top Water
Pouring Structure
WA
TER
󱎴 Air-Cleaning Filter
Selecting sterilized humidification maintains the water temperature in the heater at over 75to prevent propagation of psychrophilic bacteria for sanitary humidification.
Top Water
Pouring Structure
STERILIZESTERILIZE
WA
TER
4-Step
󱎵 Sterilized Humidification Function
The Nano-silver antibacterial tray inhibits the propagation of bacteria in water and can be dispatched from the main body to allow easy and convenient cleaning.
Top Water
Pouring Structure
WA
TER
4-Step
󱎶 Nano-Silver Antibacterial Tray for Cleaning
A silicon nebulizer cap is applied to the fitted to the nebulizer to prevent foreign materials from being generated.
󱎸 Silicon Nebulizer Cap
Top Water
Pouring Structure
STERILIZE
PROGRAM
SLEEP
HEALTHHEALTHHEALTH
WA
TER
4-Step
CHILD
Precaution
07/08
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지9
Precaution
How to use
Troubleshooting
A consumer can open/close the water tank cap using minimal force.
󱎹 Ez Water Tank Cap
If the water in the water tank is low, the water empty indicator on the display window is turned on along with no-water melody.
WA
TERWATER
󱎺 Empty Indicator Function
According to the consumer’s needs, the spray amount can be adjusted from Weak to Middle to Strong to Turbo.
WA
TER
4-Step4-Step
󱎻 4-Step Spray Adjustment Function
Desired humidity is maintained.
WA
TER
4-Step
SLEEP
CHILD
HEALTH
STERILIZE
CURRENT
HOUR
TIMER
CONT.
DESIRED
PROGRAM
WATER
CURRENT DESIRED
HOUR
TIMER
CONT.
󱎼 Humidity Adjustment
Humidity suitable for a baby is maintained. This mode is released when selecting Humid Adjustment or Spray Adjustment.
CHILDCHILD
󱎽 Child Care Mode
Optimal humidity is maintained to protect skin and avoid cold. This mode is released when selecting Humid Adjustment or Spray Adjustment.
HEALTHHEALTHHEALTHHEALTH
WA
TER
4-Step
CHILD
󱎾 Healthy Mode
Selecting the Artificial Intelligence button adjusts the indoor humidity with Mycom and selecting the Sleep mode changes to a low noise status to make a comfortable sleep environment.
󱎿 Artificial Intelligence Function and Sleep Function
PROGRAMPROGRAM
SLEEPSLEEP
HEALTHHEALTHHEALTH
WATER
4-Step
CHILD
Consumers can set the time for humidification. When the set time passes, humidification will stop.
󱏀 Humidification Time Reservation Function
CURRENT DESIRED
HOUR
TIMER
CONT.
PROGRAM
SLEEP
HEALTHHEALTHHEALTH
WA
TER
4-Step
CHILD
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지10
Parts descriptions
Parts Description / Display LED / Control Panel
09/10
Water tank lid
2-way mist outlet
Fine spray nozzle
Iodine filter
Nano-silver antibacterial tray for cleaning
Cleaning brush
Nebulizer
Control panel
Vent
Power cord
Spray guiding pipe
Water tank
Ez water
tank cap
Air-cleaning
filter
Main body
Water level
sensor
Load
Completely lock the
Water tank lid
while operating
the
appliance.
This is the passage
for water particles.
Do not push the
load intentionally.
After filling water
in the water tank,
firmly lock the
Ez water tank cap
to prevent leakage
of the water.
If the water in the water tank is low,
this
appliance will
detect it by itself
and stop the water spray.
Air flowing
into the
appliance is
purified
through this
filter
.
Refer to control panel
instruction
(see Page10)
Bidirectional spray is available while fine mist sprayed.
This allows fine water particles to be passed and large water particles to be removed.
Ion exchange resin and iodine resin purify the water.
Change this filter every three months.
This is used to clean the nebulizer surface.
Clean this after dispatching from the main body.
Wind comes in and out. Ensure that water does not enter the vent while cleaning the
appliance.
This makes water mist.
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지11
Precaution
How to use
Troubleshooting
Display LED / Control Panel
Sterilized
humidification
Sleep mode
Spray amount
Desired humidity
Reserved time
Reserve
Continue
AI mode
Child care mode
Health Mode
Power button
Customization button
Sterilized humidification button
Spray adjustment button
Humidity adjustment button
Time setting button
Current humidity
If the Program, Sleep, Cilde care, and Health modes are all turned off, the current
mode will be manual mode.
Empty indicator
This displays
sterilized
humidification.
When water is
low, this is
turned on
along with melody.
This displays the current humidity around the product.
This displays the desired humidity.
This indicates the product is continuously operating.
This indicates the operation time is set.
This displays the reserved time.
This sets the time of product operation.
This selects the desired humidity.
This selects Weak, Middle, Strong, and Turbo.
This selects sterilized humidification.
This selects Program Sleep Child Health Manual.
This turns the power on/off.
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지12
CURRENT
PROGRAM
DESIRED
CONT.
TIMER
HOUR
SLEEP
CHILD
HEALTH
STERILIZE
WATER
Direction for use
Turn the water tank lid anti-clockwise to `OPEN’to dispatch it from the main body.
Fill the water by using containers such as kettles.
Use clean tap water.
Do not use coldwater under 42.8 (6℃) or
warm water over 95℉(35 ℃).
Doing so may cause nebulizer malfunction.
The use of undergrounse poor water spray or
appliance failure.
Fill water to more than half the water tank but less than the ‘MAX’level.
If water is lower than half the water
tank,
humidification may be delayed.
If water is supplied up to the‘MAXlevel, the
water will overflow.
Do not splash water around the water tank while supplying water.
After topping up the water, dry the water tank with a clean cloth.
Direction for use
11/12
Filling the water tank through the top water pouring.
Coins, nails and screws in the reservoir result in the malfunction of the nebulizer part. Please check before starting. In addition, disconnect the water tank, drain the water in the reservoir thoroughly and check if the air-cleaning filter is mounted on the bottom of the appliance.
After initially filling with the water, the humidification starts after approx. 20seconds~4minutes. Wash the water tank before initial use to spray more comfortable mist.
Fill with water before plugging the power cord. (No water may cause nebulizer malfunction.)
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지13
Precaution
How to use
Troubleshooting
Insert the water tank lid while aligning the upper protrusion with‘OPEN’and turn the cap clockwise until the protrusion reaches
CLOSEto close it.
If this appliance is used without the water tank lid, spray may not
work because water is not supplied.
Cautions for top water pouring
Do not intentionally press the load
with a chopstick or other tools.
The spray may become weak or stop due
to the increase in water level in the reservoir and water leakage may cause appliance failure or fire.
Do not open/close the water tank lid
more than 6 times consecutively.
The spray may become weak or stop due to
the increase in water level in the reservoir and water leakage may cause appliance failure or fire.
Clean the reservoir and the water tank once every two days.
Keep the appliance out of reach of children.
Change the water everyday.
Introduction
If there is no water tank lid,
the humidification does not start after approx. 10~20 minutes.
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지14
Direction for use
Turn the Ez water tank cap anti-clockwise to open the cap.
Remove the 2-way mist outlet and spray nozzle.
SLEEP
CHILD
HEALTH
STERILIZE
CURRENT
HOUR
TIMER
CONT.
DESIRED
PROGRAM
WATER
SLEEP
CHILD
HEALTH
STERILIZE
CURRENT
HOUR
TIMER
CONT.
DESIRED
PROGRAM
WATER
Lift the water tank.
Lift the water tank by using the handle on the upper water tank.
Do not lift and transport the main body and the
water tank together.
Direction for use
13/14
Filling the water tank through the lower water inlet
If the water tank is transported with
the 2-way mist outlet detached, mist outlet may be damaged.
ONIX-MHS-E5010X_eng_081029 2008.10.29 8:48 PM 페이지15
Loading...
+ 35 hidden pages