Filac
3000 EZ/EZA Electronic Thermometer
™
I. About Body Temperature
It is a common myth that 98.6°F (37°C) is the “normal body temperature.” The truth is that 98.6°F (37°C) is an average body
temperature. Normal body temperature is actually a range that varies with age, gender, and measurement site. Body temperatures
also fluctuate through out the day, typically cooler temperatures in the morning, warmer in the afternoon, and cooling down again
in the evening. Other factors that can influence body temperature are: the patient’s recent level of activity, metabolism rate, or
medications. Normal body temperatures also tend to decrease with age.
Please see the chart below for normal temperature ranges by patient age and site. Readings from different body sites, even when
taken at the same time, should not be directly compared; body temperatures will vary by site.
Temperature
Site
Ear
Oral
Core
Rectal
Axillary
References:
Chamberlain, J, Terndrup, T., et al. (1995) Determination of Normal Ear Temperature with an Infrared Emission Detection Thermometer. Annals of Emergency
Medicine, Volume 25, Issue 1, Pages 15-20
Braim. S., Preston, P., and Smith, R. (1988) Getting a better read on thermometry. RN. 1998 Mar; 61(3):57-60
Munk, P, Woods, S, Leduc, D., et al Canadian Paediatric Society Statement; Temperature Measurement in Paediatrics; Paediatric Child Health Vol 5 No 5: July/
August, 2000
Brunner, L. and Suddarth, Dl, et al. (1982) The Lippincott Manual of Nursing Practice, Third Edition; J. B. Lippincott Company, Philadelphia, PA; 1982; p.1145
Houdas, Y. and Ring, E. F. J. Human Body Temperature, Its Measurement and Regulation; Plenum Press, NY, 1982; p.81-87.
Normal Body Temperatures by Patients Age
0-2 Years
97.5°- 100.4°F
36.3°- 38.0°C
-
-
97.5° - 100.0°F
36.3°- 37.7°C
97.9° - 100.4°F
36.6°- 38.0°C
94.5° - 99.1°F
34.7°- 37.2°C
3-10 Years
97.0°- 100.0°F
36.1°- 37.7°C
95.9° - 99.5°F
35.3°- 37.5°C
97.5° - 100.0°F
36.3°- 37.7°C
97.9°- 100.4°F
36.5°- 38.0°C
96.6° - 98.0°F
35.8°- 36.6°C
11-65 Years
96.6° - 99.7°F
35.8°- 37.6°C
97.6° - 99.6°F
36.7°- 37.8°C
98.2° - 100.2°F
36.7°- 37.8°C
98.6° - 100.6°F
37.0°- 38.1°C
95.3° - 98.4°F
35.1°- 36.8°C
> 65 Years
96.4° - 99.5°F
35.7°- 37.5°C
96.4° - 98.5°F
35.7°- 36.9°C
96.6° - 98.8°F
35.8°- 37.1°C
97.1° - 99.2°
36.1°- 37.3°C
96.0° - 97.4°F
35.5°- 36.3°C
II. General Information
1. The Filac 3000 EZ/EZA Electronic Thermometer is a fast, highly accurate, and easy to use clinical instrument for measuring
patient temperatures by Oral, Axillary or Rectal means.
2. The electromagnetic compatibility of this device has been verified by test according to the EN60601-1-2:2001requirements.
3. This device requires no user maintenance other than periodic cleaning and replacement of expired batteries.
Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.
1. Read this booklet thoroughly before using the Filac 3000 EZ/EZA Electronic Thermometer.
2. Do not use this device near flammable anesthetics. Not suitable for use in the presence of flammable anesthetic mixture with
air, oxygen or nitrous oxide, or an oxygen rich environment.
3. Do not use this thermometer without first installing a new Filac 3000 EZ/EZA Electronic Thermometer probe cover.
4. Use only Filac 3000 EZ/EZA Electronic Thermometer probe covers with this device.
Use of any other probe cover will result in erroneous temperature readings.
5. The device and probe covers are Non-sterile. Do not use on abraded tissue.
6. To limit cross contamination, use Blue devices for Oral and Axillary temperature taking only.
7. Use
8. Thoroughly dry all electrical contacts on both probe and thermometer after washing, or device may fail to functionproperly.
9. For re-calibration, service or integrity checks, refer to a qualified Biomedical Technician or return to manufacturer.
10.
11. Disposal of used probe covers must be performed in accordance with current medical practices or local regulations regarding
12. Do not use lithium batteries with this device.
13. Do not mix alkaline and rechargeable batteries.
14. Removal of the batteries is recommended if the unit is not going to be used for an extended period of time.
15. Dispose of batteries in a manner consistent with local environmental and institutional policy for Alkaline batterydisposal.
16. Dispose of old battery-powered electronic equipment in a manner consistent with institutional policy for expired
17. Cleaning frequency and practices must be consistent with institutional policy for cleaning of non-sterile devices.
18. Device to be used by trained personnel.
red
devices only for
Warning:
may affect calibration and voids warranty.
disposal of infectious, biological medical waste.
equipmentdisposal.
No modification of this equipment is allowed. Do not open unit. No user-serviceable parts inside. Opening of device
rectal
temperatures.
Note:
Even though this device has been designed to minimize the effects of electromagnetic interference, it does generate radio frequency
energy. If not used in accordance with the instructions, the device could cause interference in other equipment operating within its
vicinity. If the device is causing interference, the following actions may be taken in an attempt to correct the interference:
•Re-orientorre-locatethereceivingdevice.
•Increasetheseparationbetweenthedevices.
•Consultacustomerservicerepresentative.
Filac
3000 EZ/EZA Electronic Thermometer
™
Table of Contents
2
IV. Icon Identification
ORAL
Temperature Mode
Works only with BLUE probe
and isolation chamber
AXILLARY
Temperature Mode
Works only with BLUE probe
and isolation chamber
RECTAL
Temperature Mode
Works only with RED probe
and isolation chamber
Site Button
Use to change
measurementlocation
°C/°F Button
Use to change
temperaturescale
Direct Mode
Non-predictive temperature
measurement mode
Out of Range - High
Temperature measurement
is above 109°F (43°C)
Out of Range - Low
Temperature measurement
is below 86°F (30°C)
Non-Sterile
Latex-free
Single use
By prescription only
Keep away from sunlight
Keep dry
EN 50419
Dispose of as Electrical and
Electronic waste
Type BF Equipment
Degree of protection against
electrical shock – no
conductive connection
to the patient
Non-ionizing
electromagnetic radiation
Medical Electrical
Equipment
Install/Remove Probe Cover
Flashing probe cover reminder
to install probe cover prior to
use and remove cover after use
Low Battery
Battery voltage is low – replace
batteries as soon as possible
Dead Battery
Unit will not operate until
new batteries are installed
Progress Bar
Temperature measurement
status indication
10%
-13°F
-25°C
DEHP-free
Follow instructions for use -
This manual must be read prior
to use of the thermometer
(Symbol appears blue
ondevice)
95%
Humidity limitations
131°F
55°C
Temperature limitations
CE mark
0123
Manufacturer
Serial Number
Date of Manufacture
Manufacturer
Authorized
representative in the
European Community
Filac
3000 EZ/EZA Electronic Thermometer
™