80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
12 Amps
50/60 Hz
700 Watts
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 11.84%, 50% Load)
0.80 0.96 23.06% 10% 87.87 11.9/0.02 3.33/1.45 5.12/1.33 5.11/0.24 70.55 80.29%
1.49 0.96 25.85% 20% 164.30 11.89/0.05 3.32/2.9 5.11/2.63 5.1/0.49 141.08 85.86%
3.52 0.99 11.84% 50% 400.20 11.91/0.12 3.31/7.24 5.09/6.58 5.06/1.22 352.21 88.01%
7.27 0.99 8.54% 100% 830.00 12.02/0.24 3.27/14.49 5.05/13.14 5/2.45 699.15 84.23%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
800
900
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
-200
-100
0
100
200
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current