DUT SPECIFICATIONS
Rated Voltage (Vrms)100-240
Rated Current (Arms)10-5
Rated Frequency (Hz)47-63
Rated Power (W)850
TypeATX12V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
PAGE 1/8
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
Corsair RM850 (2019) (Sample #2)
RESULTS
Test Date04-03-2019
Cybenetics ID #663
Temperature Range (°C /°F)30-32 / 86-89.6
Average Efficiency90.727
Efficiency With 10W (≤500W) or 2% (>500W) Load -115V78.436
Average Efficiency 5VSB76.773
Standby Power Consumption (W) -115V0.0392914
Standby Power Consumption (W) -230V0.0712672
Average PF0.964
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Avg Noise Output25.68
Efficiency Rating (ETA)ETA-A
Noise Rating (LAMBDA)LAMBDA-A-
TEST EQUIPMENT
Chroma 6314A x2
Electronic Loads
AC SourcesChroma 6530, Chroma 61604, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2, N4L PPA5530
OscilloscopesPicoscope 4444 & 3424, Keysight DSOX3024A, Rigol DS2072A
VoltmeterKeithley 2015 THD 6.5 Digit
Sound AnalyzerBruel & Kjaer 2250-L G4
MicrophoneBruel & Kjaer Type 4955-A, Bruel & Kjaer Type 4189
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY GRAPH
Corsair RM850 (2019) (Sample #2)
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/8
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.227
1
5.042V0.325115.13V
0.090A0.454
2
5.042V0.610115.13V
0.550A2.767
3
5.030V3.532115.13V
1.000A5.019
4
5.019V6.481115.13V
1.500A7.509
5
5.006V9.710115.13V
DC/AC
(Watts)
EfficiencyPF/AC Volts
69.846%
74.426%
78.341%
77.442%
77.333%
0.032
0.060
0.259
0.348
0.397
Corsair RM850 (2019) (Sample #2)
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.227
1
5.042V0.363230.27V
0.090A0.454
2
5.041V0.653230.27V
0.550A2.767
3
5.030V3.622230.27V
1.000A5.018
4
5.018V6.506230.27V
1.500A7.507
5
5.005V9.731230.27V
DC/AC
(Watts)
EfficiencyPF/AC Volts
0.011
62.534%
0.019
69.525%
0.101
76.394%
0.166
77.129%
0.222
77.145%
6
3.000A14.902
4.967V19.439115.13V
VAMPIRE POWER -230V
76.660%
0.459
6
3.000A14.895
77.072%
4.965V19.326230.26V
0.319
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/8
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Corsair RM850 (2019) (Sample #2)
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
PAGE 5/8
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
10-110% LOAD TESTS
Test
#
1
2
3
4
5
12V5V3.3V5VSB
5.221A1.983A1.994A0.996A84.880
12.119V5.045V3.309V5.023V96.14339.79°C230.26V
11.429A2.976A2.994A1.196A169.390
12.117V5.042V3.306V5.017V183.24240.26°C230.26V
18.055A3.475A3.480A1.397A254.493
12.101V5.040V3.303V5.011V272.38541.14°C230.26V
24.704A3.971A3.998A1.599A339.698
12.083V5.037V3.301V5.004V364.24447.72°C230.26V
31.036A4.967A5.002A1.801A424.999
12.066V5.035V3.300V4.999V456.87648.78°C230.25V
DC/AC
(Watts)
Corsair RM850 (2019) (Sample #2)
Fan
Efficiency
88.285%0<6.0
92.441%0<6.0
93.431%0<6.0
93.261%78316.1
93.023%78416.1
Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
44.14°C0.847
45.27°C0.937
46.86°C0.962
41.61°C0.974
42.13°C0.979
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
37.311A5.963A6.005A2.003A509.520
92.569%78516.2
12.053V5.032V3.298V4.993V550.42249.87°C230.26V
43.661A6.961A7.010A2.207A594.831
92.052%87719.6
12.041V5.029V3.295V4.986V646.19051.58°C230.26V
50.015A7.958A8.016A2.410A680.183
91.437%114228.7
12.032V5.027V3.293V4.980V743.88552.80°C230.27V
56.773A8.461A8.502A2.411A765.099
90.858%140834.8
12.023V5.025V3.293V4.979V842.08154.37°C230.26V
63.272A8.962A9.025A3.025A849.943
90.162%173440.6
12.015V5.023V3.292V4.960V942.68456.45°C230.26V
70.367A8.965A9.030A3.027A934.688
89.459%175340.8
12.008V5.021V3.289V4.958V1044.82757.85°C230.27V
0.136A18.005A18.000A0.000A151.487
84.474%104325.5
12.112V5.023V3.300V5.077V179.33048.91°C230.27V
70.838A1.002A1.000A1.000A864.800
90.608%172540.5
12.020V5.029V3.289V4.999V954.43956.54°C230.26V
42.62°C0.982
43.31°C0.984
43.58°C0.986
44.31°C0.987
45.66°C0.988
46.59°C0.988
42.60°C0.936
45.72°C0.988
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 7/8
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)20.5
AC Loss to PWR_OK Hold Up Time (ms)18.0
PWR_OK Inactive to DC Loss Delay (ms)2.5
Corsair RM850 (2019) (Sample #2)
CERTIFICATIONS
All dataand graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/8
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.