Corsair RM850 User Manual

EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
DUT INFORMATION
Brand Corsair Manufacturer (OEM) Channel Well Technology Series RM Model Number RM850 (2019) (Sample #2) Serial Number 19027122000038940012 DUT Notes CP-9020196
DUT SPECIFICATIONS
Rated Voltage (Vrms) 100-240 Rated Current (Arms) 10-5 Rated Frequency (Hz) 47-63 Rated Power (W) 850 Type ATX12V
Cooling
Semi-Passive Operation Cable Design Fully Modular
Corsair RM850 (2019) (Sample #2)
140mm Sleeve Bearing Fan (HA1425M12F-Z)
POWER SPECIFICATIONS
Rail 3.3V 5V 12V 5VSB -12V
Max. Power
Total Max. Power (W) 850
Amps 20 20 70.8 3 0.3 Watts 150 849.6 15 3.6
CABLES AND CONNECTORS
Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors ATX connector 20+4 pin (610mm) 1 1 18-20AWG No 4+4 pin EPS12V (650mm) 2 2 18AWG No 6+2 pin PCIe (600mm+150mm) 3 6 16-18AWG No SATA (460mm+110mm+110mm+110mm) 3 12 18AWG No 4 pin Molex (450mm+100mm+100mm+100mm) 1 4 18AWG No AC Power Cord (1420mm) - C13 coupler 1 1 16AWG -
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
PAGE 1/8
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
Corsair RM850 (2019) (Sample #2)
RESULTS
Test Date 04-03-2019 Cybenetics ID # 663 Temperature Range (°C /°F) 30-32 / 86-89.6 Average Efficiency 90.727 Efficiency With 10W (≤500W) or 2% (>500W) Load -115V 78.436 Average Efficiency 5VSB 76.773 Standby Power Consumption (W) -115V 0.0392914 Standby Power Consumption (W) -230V 0.0712672 Average PF 0.964 ErP Lot 3/6 Ready ✓ (EU) No 617/2013 Compliance ✓ Avg Noise Output 25.68 Efficiency Rating (ETA) ETA-A Noise Rating (LAMBDA) LAMBDA-A-
TEST EQUIPMENT
Chroma 6314A x2
Electronic Loads
AC Sources Chroma 6530, Chroma 61604, Keysight AC6804B Power Analyzers N4L PPA1530 x2, N4L PPA5530 Oscilloscopes Picoscope 4444 & 3424, Keysight DSOX3024A, Rigol DS2072A Voltmeter Keithley 2015 THD 6.5 Digit Sound Analyzer Bruel & Kjaer 2250-L G4 Microphone Bruel & Kjaer Type 4955-A, Bruel & Kjaer Type 4189 Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
63123A x6 63102A 63101A
Chroma 63601-5 x4 Chroma 63600-2 x2 63640-80-80 x20 63610-80-20 x2
PAGE 2/8
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY GRAPH
Corsair RM850 (2019) (Sample #2)
INFO
This graph depicts the PSU’s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 3/8
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test # 5VSB
0.045A 0.227
1
5.042V 0.325 115.13V
0.090A 0.454
2
5.042V 0.610 115.13V
0.550A 2.767
3
5.030V 3.532 115.13V
1.000A 5.019
4
5.019V 6.481 115.13V
1.500A 7.509
5
5.006V 9.710 115.13V
DC/AC (Watts)
Efficiency PF/AC Volts
69.846%
74.426%
78.341%
77.442%
77.333%
0.032
0.060
0.259
0.348
0.397
Corsair RM850 (2019) (Sample #2)
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test # 5VSB
0.045A 0.227
1
5.042V 0.363 230.27V
0.090A 0.454
2
5.041V 0.653 230.27V
0.550A 2.767
3
5.030V 3.622 230.27V
1.000A 5.018
4
5.018V 6.506 230.27V
1.500A 7.507
5
5.005V 9.731 230.27V
DC/AC (Watts)
Efficiency PF/AC Volts
0.011
62.534%
0.019
69.525%
0.101
76.394%
0.166
77.129%
0.222
77.145%
6
3.000A 14.902
4.967V 19.439 115.13V
VAMPIRE POWER -230V
76.660%
0.459
6
3.000A 14.895
77.072%
4.965V 19.326 230.26V
0.319
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 4/8
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Corsair RM850 (2019) (Sample #2)
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
PAGE 5/8
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
10-110% LOAD TESTS
Test #
1
2
3
4
5
12V 5V 3.3V 5VSB
5.221A 1.983A 1.994A 0.996A 84.880
12.119V 5.045V 3.309V 5.023V 96.143 39.79°C 230.26V
11.429A 2.976A 2.994A 1.196A 169.390
12.117V 5.042V 3.306V 5.017V 183.242 40.26°C 230.26V
18.055A 3.475A 3.480A 1.397A 254.493
12.101V 5.040V 3.303V 5.011V 272.385 41.14°C 230.26V
24.704A 3.971A 3.998A 1.599A 339.698
12.083V 5.037V 3.301V 5.004V 364.244 47.72°C 230.26V
31.036A 4.967A 5.002A 1.801A 424.999
12.066V 5.035V 3.300V 4.999V 456.876 48.78°C 230.25V
DC/AC (Watts)
Corsair RM850 (2019) (Sample #2)
Fan
Efficiency
88.285% 0 <6.0
92.441% 0 <6.0
93.431% 0 <6.0
93.261% 783 16.1
93.023% 784 16.1
Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
44.14°C 0.847
45.27°C 0.937
46.86°C 0.962
41.61°C 0.974
42.13°C 0.979
PF/AC Volts
6
7
8
9
10
11
CL1
CL2
37.311A 5.963A 6.005A 2.003A 509.520
92.569% 785 16.2
12.053V 5.032V 3.298V 4.993V 550.422 49.87°C 230.26V
43.661A 6.961A 7.010A 2.207A 594.831
92.052% 877 19.6
12.041V 5.029V 3.295V 4.986V 646.190 51.58°C 230.26V
50.015A 7.958A 8.016A 2.410A 680.183
91.437% 1142 28.7
12.032V 5.027V 3.293V 4.980V 743.885 52.80°C 230.27V
56.773A 8.461A 8.502A 2.411A 765.099
90.858% 1408 34.8
12.023V 5.025V 3.293V 4.979V 842.081 54.37°C 230.26V
63.272A 8.962A 9.025A 3.025A 849.943
90.162% 1734 40.6
12.015V 5.023V 3.292V 4.960V 942.684 56.45°C 230.26V
70.367A 8.965A 9.030A 3.027A 934.688
89.459% 1753 40.8
12.008V 5.021V 3.289V 4.958V 1044.827 57.85°C 230.27V
0.136A 18.005A 18.000A 0.000A 151.487
84.474% 1043 25.5
12.112V 5.023V 3.300V 5.077V 179.330 48.91°C 230.27V
70.838A 1.002A 1.000A 1.000A 864.800
90.608% 1725 40.5
12.020V 5.029V 3.289V 4.999V 954.439 56.54°C 230.26V
42.62°C 0.982
43.31°C 0.984
43.58°C 0.986
44.31°C 0.987
45.66°C 0.988
46.59°C 0.988
42.60°C 0.936
45.72°C 0.988
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 6/8
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
20-80W LOAD TESTS
Test # 12V 5V 3.3V 5VSB
1.196A 0.495A 0.483A 0.199A 19.538
1
12.075V 5.044V 3.305V 5.039V 24.717 230.25V
2.457A 0.990A 0.996A 0.397A 39.980
2
12.083V 5.045V 3.310V 5.037V 46.988 230.24V
3.647A 1.486A 1.481A 0.596A 59.460
3
12.082V 5.045V 3.309V 5.033V 68.190 230.25V
4.881A 1.982A 1.993A 0.796A 79.882
4
12.146V 5.045V 3.309V 5.029V 90.931 230.25V
RIPPLE MEASUREMENTS
DC/AC (Watts)
Corsair RM850 (2019) (Sample #2)
Efficiency
79.047% 0 <6.0
85.086% 0 <6.0
87.198% 0 <6.0
87.849% 0 <6.0
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
0.427
0.649
0.762
0.835
Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 5.3 mV 6.6 mV 9.2 mV 7.9 mV Pass 20% Load 10.9 mV 7.2 mV 10.3 mV 7.8 mV Pass 30% Load 8.6 mV 8.0 mV 10.6 mV 8.3 mV Pass 40% Load 8.3 mV 9.8 mV 12.9 mV 9.7 mV Pass 50% Load 8.2 mV 9.6 mV 11.8 mV 8.5 mV Pass 60% Load 9.9 mV 9.9 mV 12.4 mV 8.7 mV Pass 70% Load 9.3 mV 10.7 mV 14.2 mV 8.2 mV Pass 80% Load 9.8 mV 12.1 mV 16.5 mV 8.7 mV Pass 90% Load 10.9 mV 12.8 mV 16.9 mV 9.0 mV Pass 100% Load 15.9 mV 13.9 mV 17.4 mV 9.9 mV Pass 110% Load 16.9 mV 14.4 mV 18.8 mV 9.7 mV Pass Crossload 1 18.2 mV 10.6 mV 15.6 mV 8.9 mV Pass Crossload 2 15.1 mV 11.7 mV 15.2 mV 9.4 mV Pass
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 7/8
info@cybenetics.com
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms) 20.5 AC Loss to PWR_OK Hold Up Time (ms) 18.0 PWR_OK Inactive to DC Loss Delay (ms) 2.5
Corsair RM850 (2019) (Sample #2)
CERTIFICATIONS
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 8/8
info@cybenetics.com