EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM750x (2018) (Sample #3)
General Data
Manufacturer (OEM)CWT
Primary Side
Transient Filter4x Y caps, 2x X caps, 2x CM chokes, 1x MOV
Inrush ProtectionNTC Thermistor & Relay
Bridge Rectifier(s)2xGBU1506(600V, 15A @ 100°C)
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM750x (2018) (Sample #3)
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
115V
Average Efficiency87.630%
Efficiency With 10W (≤500W) or 2% (>500W)58.028
Average Efficiency 5VSB77.622%
Standby Power Consumption (W)0.0314856
Average PF0.990
Avg Noise Output18.86 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-A+
230V
Average Efficiency89.391%
Average Efficiency 5VSB77.613%
Standby Power Consumption (W)0.0471742
Average PF0.966
Avg Noise Output17.00 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-A+
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289, Keithley 2015 - THD
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)22.7
AC Loss to PWR_OK Hold Up Time (ms)19.8
PWR_OK Inactive to DC Loss Delay (ms)2.9
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Corsair RM750x (2018) (Sample #3)
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM750x (2018) (Sample #3)
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.227
70.717%
5.050V0.321115.17V
0.090A0.454
75.041%
5.048V0.605115.13V
0.550A2.768
78.905%
5.032V3.508115.18V
1.000A5.018
78.101%
5.018V6.425115.18V
1.500A7.503
77.663%
5.002V9.661115.18V
3.000A14.870
76.050%
4.957V19.553115.19V
0.032
0.059
0.255
0.343
0.392
0.454
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.227
64.672%
5.049V0.351230.24V
0.090A0.454
71.160%
5.048V0.638230.24V
0.550A2.767
77.334%
5.033V3.578230.24V
1.000A5.018
77.968%
5.019V6.436230.24V
1.500A7.505
77.788%
5.004V9.648230.24V
2.998A14.865
77.025%
4.959V19.299230.24V
0.010
0.019
0.100
0.165
0.221
0.319
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM750x (2018) (Sample #3)
115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 6/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 115V
Corsair RM750x (2018) (Sample #3)
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 7/16
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -115V
Corsair RM750x (2018) (Sample #3)
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 115V
Test #12V5V3.3V5VSB
4.381A1.990A2.000A0.998A74.952
1
12.178V5.027V3.299V5.008V88.12540.23°C115.17V
9.792A2.986A3.006A1.200A150.004
2
12.164V5.022V3.293V5.000V167.64540.96°C115.16V
15.540A3.488A3.515A1.402A225.003
3
12.159V5.017V3.287V4.992V248.19941.00°C115.16V
21.310A3.992A4.024A1.606A299.998
4
12.144V5.011V3.281V4.983V329.86541.35°C115.16V
26.708A4.995A5.040A1.809A374.372
5
12.126V5.006V3.275V4.975V413.76348.66°C115.16V
DC/AC
(Watts)
Corsair RM750x (2018) (Sample #3)
Efficiency
85.052%0<6.0
89.477%0<6.0
90.654%0<6.0
90.946%0<6.0
90.480%62211.1
Fan Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
44.30°C0.976
45.46°C0.989
46.22°C0.993
47.13°C0.993
42.21°C0.991
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
32.170A6.003A6.059A2.000A449.238
90.016%62311.1
12.107V5.000V3.269V4.967V499.06250.34°C115.15V
37.673A7.011A7.083A2.217A524.618
89.383%62311.1
12.091V4.994V3.262V4.960V586.93151.74°C115.15V
43.190A8.002A8.105A2.423A599.830
88.637%80319.8
12.075V4.989V3.256V4.952V676.72552.57°C115.14V
49.092A8.530A8.612A2.425A674.444
87.928%96826.4
12.058V4.983V3.250V4.948V767.04353.80°C115.14V
54.806A9.042A9.153A3.044A749.662
87.078%119833.1
12.042V4.977V3.244V4.926V860.91355.01°C115.13V
61.129A9.051A9.169A3.048A824.889
86.302%140137.7
12.027V4.971V3.239V4.921V955.81658.39°C115.13V
0.100A17.999A17.999A0.000A150.229
80.512%74917.5
12.151V5.010V3.269V5.083V186.59249.79°C115.17V
62.496A1.000A1.001A1.000A766.157
87.790%111831.1
12.048V4.985V3.256V4.960V872.71658.01°C115.13V
42.71°C0.992
43.45°C0.993
43.81°C0.994
44.63°C0.994
44.86°C0.995
46.51°C0.996
43.01°C0.992
46.77°C0.995
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 10/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM750x (2018) (Sample #3)
230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 11/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 230V
Corsair RM750x (2018) (Sample #3)
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 12/16
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -230V
Corsair RM750x (2018) (Sample #3)
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 13/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 230V
Test #12V5V3.3V5VSB
4.380A1.989A2.002A0.998A74.951
1
12.180V5.028V3.299V5.008V87.00140.02°C230.32V
9.791A2.987A3.006A1.200A150.004
2
12.165V5.022V3.292V5.001V165.75640.07°C230.31V
15.540A3.489A3.515A1.402A225.004
3
12.159V5.016V3.287V4.992V244.25741.50°C230.32V
21.313A3.992A4.024A1.605A300.007
4
12.143V5.011V3.281V4.983V324.25941.83°C230.32V
26.713A4.996A5.039A1.809A374.371
5
12.124V5.005V3.274V4.975V405.64349.27°C230.32V
DC/AC
(Watts)
Corsair RM750x (2018) (Sample #3)
Efficiency
86.150%0<6.0
90.497%0<6.0
92.118%0<6.0
92.521%0<6.0
92.291%62211.1
Fan Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
44.24°C0.839
44.84°C0.936
46.97°C0.964
48.22°C0.975
42.05°C0.981
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
32.172A6.003A6.060A2.000A449.224
92.031%62311.1
12.106V4.999V3.268V4.968V488.12250.24°C230.32V
37.679A7.011A7.084A2.217A524.613
91.639%62411.2
12.089V4.994V3.261V4.960V572.47951.60°C230.32V
43.197A8.002A8.110A2.422A599.817
91.132%75617.6
12.073V4.988V3.254V4.953V658.18553.05°C230.33V
49.101A8.530A8.618A2.424A674.446
90.679%91224.2
12.056V4.982V3.248V4.949V743.77355.18°C230.33V
54.815A9.043A9.159A3.044A749.662
90.108%116632.4
12.040V4.976V3.242V4.927V831.95956.70°C230.33V
61.144A9.053A9.173A3.047A824.885
89.588%139337.6
12.024V4.971V3.237V4.921V920.75158.37°C230.33V
0.100A17.999A17.998A0.000A150.208
81.131%75017.5
12.151V5.010V3.268V5.087V185.14350.70°C230.35V
62.500A1.000A1.000A1.000A765.947
90.817%111330.9
12.044V4.984V3.255V4.959V843.39654.51°C230.33V
42.34°C0.984
43.01°C0.986
43.85°C0.987
45.36°C0.989
46.15°C0.990
46.68°C0.990
43.62°C0.946
43.83°C0.990
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 15/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
Anex
Corsair RM750x (2018) (Sample #3)
CERTIFICATIONS 115V
CERTIFICATIONS 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 16/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.