All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 1/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
115V
Average Efficiency87.413%
Efficiency With 10W (≤500W) or 2% (>500W)44.819
Average Efficiency 5VSB77.313%
Standby Power Consumption (W)0.0318090
Average PF0.990
Avg Noise Output16.48 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-A+
230V
Average Efficiency89.338%
Average Efficiency 5VSB77.139%
Standby Power Consumption (W)0.0472340
Average PF0.961
Avg Noise Output16.52 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-A+
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289, Keithley 2015 - THD
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)23
AC Loss to PWR_OK Hold Up Time (ms)20.7
PWR_OK Inactive to DC Loss Delay (ms)2.3
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Corsair RM550x (2018) (Sample #3)
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.227
70.717%
5.048V0.321115.17V
0.090A0.454
75.041%
5.046V0.605115.17V
0.550A2.766
78.781%
5.029V3.511115.17V
1.000A5.014
77.881%
5.014V6.438115.17V
1.500A7.499
77.381%
5.000V9.691115.17V
2.999A14.842
75.779%
4.949V19.586115.17V
0.037
0.069
0.276
0.358
0.403
0.462
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.227
65.043%
5.048V0.349230.32V
0.090A0.454
71.272%
5.046V0.637230.32V
0.550A2.766
77.176%
5.029V3.584230.32V
1.000A5.013
77.842%
5.014V6.440230.28V
1.500A7.498
77.443%
4.999V9.682230.32V
2.999A14.834
76.630%
4.946V19.358230.32V
0.012
0.022
0.115
0.186
0.243
0.334
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...