All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 1/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
115V
Average Efficiency87.413%
Efficiency With 10W (≤500W) or 2% (>500W)44.819
Average Efficiency 5VSB77.313%
Standby Power Consumption (W)0.0318090
Average PF0.990
Avg Noise Output16.48 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-A+
230V
Average Efficiency89.338%
Average Efficiency 5VSB77.139%
Standby Power Consumption (W)0.0472340
Average PF0.961
Avg Noise Output16.52 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-A+
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289, Keithley 2015 - THD
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)23
AC Loss to PWR_OK Hold Up Time (ms)20.7
PWR_OK Inactive to DC Loss Delay (ms)2.3
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Corsair RM550x (2018) (Sample #3)
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.227
70.717%
5.048V0.321115.17V
0.090A0.454
75.041%
5.046V0.605115.17V
0.550A2.766
78.781%
5.029V3.511115.17V
1.000A5.014
77.881%
5.014V6.438115.17V
1.500A7.499
77.381%
5.000V9.691115.17V
2.999A14.842
75.779%
4.949V19.586115.17V
0.037
0.069
0.276
0.358
0.403
0.462
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.227
65.043%
5.048V0.349230.32V
0.090A0.454
71.272%
5.046V0.637230.32V
0.550A2.766
77.176%
5.029V3.584230.32V
1.000A5.013
77.842%
5.014V6.440230.28V
1.500A7.498
77.443%
4.999V9.682230.32V
2.999A14.834
76.630%
4.946V19.358230.32V
0.012
0.022
0.115
0.186
0.243
0.334
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 115V
Corsair RM550x (2018) (Sample #3)
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 6/15
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -115V
Corsair RM550x (2018) (Sample #3)
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 7/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 115V
Test #12V5V3.3V5VSB
2.766A1.988A1.994A0.998A54.953
1
12.061V5.031V3.306V5.008V64.93840.68°C115.17V
6.565A2.986A2.999A1.200A110.011
2
12.050V5.025V3.300V5.001V124.31340.97°C115.17V
10.702A3.486A3.506A1.402A165.002
3
12.049V5.021V3.295V4.992V183.15041.65°C115.16V
14.852A3.988A4.013A1.606A220.001
4
12.038V5.017V3.290V4.983V243.03741.81°C115.17V
18.672A4.991A5.026A1.810A274.992
5
12.022V5.011V3.284V4.974V305.27549.45°C115.16V
DC/AC
(Watts)
Corsair RM550x (2018) (Sample #3)
Efficiency
84.624%0<6.0
88.495%0<6.0
90.091%0<6.0
90.522%0<6.0
90.080%62811.5
Fan Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
45.10°C0.968
46.07°C0.986
47.38°C0.990
48.23°C0.992
42.43°C0.994
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
22.503A5.996A6.041A2.000A329.916
89.799%62811.5
12.006V5.005V3.278V4.966V367.39350.28°C115.16V
26.341A7.003A7.063A2.218A385.056
89.250%62911.5
11.994V5.000V3.272V4.958V431.43451.96°C115.16V
30.178A8.003A8.083A2.424A439.926
88.560%73816.8
11.981V4.995V3.265V4.950V496.75553.26°C115.16V
34.428A8.516A8.585A2.425A494.478
87.980%84221.7
11.967V4.990V3.260V4.947V562.03254.95°C115.16V
38.485A9.037A9.132A3.049A549.676
87.236%98327.1
11.952V4.980V3.252V4.920V630.10355.81°C115.16V
43.141A9.046A9.144A3.051A604.892
86.601%109730.5
11.942V4.976V3.247V4.916V698.48458.12°C115.16V
0.101A16.001A15.998A0.000A133.838
81.525%63811.9
12.023V5.014V3.275V5.090V164.16849.60°C115.18V
45.830A1.001A1.002A1.000A562.098
88.203%98827.1
11.976V4.993V3.267V4.966V637.28155.21°C115.16V
42.56°C0.994
43.74°C0.993
44.67°C0.994
45.03°C0.994
45.28°C0.995
46.53°C0.996
42.04°C0.990
45.36°C0.995
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 9/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 10/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 230V
Corsair RM550x (2018) (Sample #3)
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 11/15
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -230V
Corsair RM550x (2018) (Sample #3)
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 12/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 230V
Test #12V5V3.3V5VSB
2.765A1.987A1.995A0.998A54.953
1
12.065V5.031V3.307V5.009V64.35640.19°C230.33V
6.563A2.986A2.999A1.200A110.016
2
12.054V5.026V3.300V5.001V122.35140.47°C230.33V
10.699A3.486A3.506A1.402A165.009
3
12.053V5.021V3.295V4.992V180.14541.45°C230.34V
14.848A3.988A4.011A1.606A220.007
4
12.042V5.017V3.290V4.983V238.76241.60°C230.34V
18.674A4.992A5.025A1.810A274.989
5
12.021V5.009V3.284V4.973V299.15649.74°C230.33V
DC/AC
(Watts)
Corsair RM550x (2018) (Sample #3)
Efficiency
85.389%0<6.0
89.918%0<6.0
91.598%0<6.0
92.145%0<6.0
91.922%63011.5
Fan Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
44.15°C0.803
45.54°C0.919
47.29°C0.953
48.25°C0.968
42.36°C0.976
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
22.506A6.006A6.054A2.000A329.901
91.736%62811.5
12.004V4.997V3.272V4.959V359.62150.58°C230.33V
26.348A7.016A7.080A2.222A385.056
91.421%62711.4
11.991V4.990V3.264V4.950V421.19051.83°C230.33V
30.178A8.003A8.102A2.428A439.773
90.947%79019.2
11.979V4.984V3.257V4.941V483.54753.51°C230.32V
34.422A8.536A8.610A2.430A494.410
90.585%89223.5
11.967V4.978V3.251V4.938V545.79954.88°C230.33V
38.477A9.052A9.150A3.052A549.612
90.106%100327.6
11.953V4.972V3.245V4.914V609.95956.38°C230.33V
43.132A9.060A9.165A3.055A604.818
89.725%113031.4
11.943V4.967V3.240V4.909V674.08358.17°C230.34V
0.103A16.001A15.998A0.000A133.701
82.890%63911.9
12.025V5.008V3.271V5.090V161.29949.43°C230.34V
45.826A1.000A0.998A1.000A561.923
91.123%97326.6
11.974V4.987V3.261V4.960V616.66456.45°C230.34V
42.47°C0.981
43.12°C0.984
44.33°C0.986
45.00°C0.988
45.73°C0.989
46.60°C0.990
42.28°C0.945
45.41°C0.989
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 14/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
CERTIFICATIONS 115V
CERTIFICATIONS 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 15/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.