Corsair RM550x User Manual

EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
Anex
Lab ID#: CR55001668 Receipt Date: Feb 14, 2018
Corsair RM550x (2018) (Sample #3)
Report: 20PS1668A
Test Date: Jun 22, 2020 Report Date: Jun 30, 2020
DUT INFORMATION
Brand Corsair Manufacturer (OEM) Channel Well Technology Series RMx Model Number RPS0107 Serial Number 17477135000034420109 DUT Notes
DUT SPECIFICATIONS
Rated Voltage (Vrms) 100-240 Rated Current (Arms) 10-5 Rated Frequency (Hz) 47-63 Rated Power (W) 550 Type ATX12V
Cooling
Semi-Passive Operation Cable Design Fully Modular
135mm Rifle Bearing Fan (NR135L)
POWER SPECIFICATIONS
Rail 3.3V 5V 12V 5VSB -12V
Max. Power
Total Max. Power (W) 550
Amps 25 25 45.8 3 0.8 Watts 130 550 15 9.6
CABLES AND CONNECTORS
Modular Cables Description Cable Count Connector Count (Total) Gauge In Cable Capacitors ATX connector 20+4 pin (600mm) 1 1 18-20AWG Yes 4+4 pin EPS12V (650mm) 1 1 18AWG Yes 6+2 pin PCIe (600mm+150mm) 1 2 18AWG Yes SATA (520mm+110mm+110mm) 2 6 18AWG No 4 pin Molex (450mm+100mm+100mm+100mm) 1 4 18AWG No FDD Adapter (+100mm) 1 1 20AWG No AC Power Cord (1430mm) - C13 coupler 1 1 18AWG -
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 1/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
RESULTS
Temperature Range (°C /°F) 30-32 / 86-89.6 ErP Lot 3/6 Ready ✓ (EU) No 617/2013 Compliance
115V
Average Efficiency 87.413% Efficiency With 10W (≤500W) or 2% (>500W) 44.819 Average Efficiency 5VSB 77.313% Standby Power Consumption (W) 0.0318090 Average PF 0.990 Avg Noise Output 16.48 dB(A) Efficiency Rating (ETA) ETA-A- Noise Rating (LAMBDA) LAMBDA-A+
230V
Average Efficiency 89.338% Average Efficiency 5VSB 77.139% Standby Power Consumption (W) 0.0472340 Average PF 0.961 Avg Noise Output 16.52 dB(A) Efficiency Rating (ETA) ETA-A- Noise Rating (LAMBDA) LAMBDA-A+
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC Sources Chroma 6530, Keysight AC6804B Power Analyzers N4L PPA1530 x2 Sound Analyzer Bruel & Kjaer 2270 G4 Microphone Bruel & Kjaer Type 4955-A Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2 Tachometer UNI-T UT372 x2 Digital Multimeter Keysight U1273AX, Fluke 289, Keithley 2015 - THD UPS CyberPower OLS3000E 3kVA x2 Transformer 3kVA x2
Chroma 63600-2 x2 63640-80-80 x20 63610-80-20 x2
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms) 23 AC Loss to PWR_OK Hold Up Time (ms) 20.7 PWR_OK Inactive to DC Loss Delay (ms) 2.3
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 2/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Corsair RM550x (2018) (Sample #3)
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB EFFICIENCY
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 3/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts
1
2
3
4
5
6
0.045A 0.227
70.717%
5.048V 0.321 115.17V
0.090A 0.454
75.041%
5.046V 0.605 115.17V
0.550A 2.766
78.781%
5.029V 3.511 115.17V
1.000A 5.014
77.881%
5.014V 6.438 115.17V
1.500A 7.499
77.381%
5.000V 9.691 115.17V
2.999A 14.842
75.779%
4.949V 19.586 115.17V
0.037
0.069
0.276
0.358
0.403
0.462
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts
1
2
3
4
5
6
0.045A 0.227
65.043%
5.048V 0.349 230.32V
0.090A 0.454
71.272%
5.046V 0.637 230.32V
0.550A 2.766
77.176%
5.029V 3.584 230.32V
1.000A 5.013
77.842%
5.014V 6.440 230.28V
1.500A 7.498
77.443%
4.999V 9.682 230.32V
2.999A 14.834
76.630%
4.946V 19.358 230.32V
0.012
0.022
0.115
0.186
0.243
0.334
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 4/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
Anex
Corsair RM550x (2018) (Sample #3)
115V
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 5/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ 10 hidden pages