All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
115V
Average Efficiency87.144%
Efficiency With 10W (≤500W) or 2% (>500W)61.692
Average Efficiency 5VSB78.614%
Standby Power Consumption (W)0.0555526
Average PF0.985
Avg Noise Output30.73 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-S++
230V
Average Efficiency89.172%
Average Efficiency 5VSB78.180%
Standby Power Consumption (W)0.0887277
Average PF0.948
Avg Noise Output30.43 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-S++
Corsair CX550F RGB
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289, Keithley 2015 - THD
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)16.4
AC Loss to PWR_OK Hold Up Time (ms)13.1
PWR_OK Inactive to DC Loss Delay (ms)3.3
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Corsair CX550F RGB
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair CX550F RGB
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.227
67.964%
5.048V0.334115.16V
0.090A0.454
73.821%
5.046V0.615115.16V
0.550A2.768
79.267%
5.034V3.492115.15V
1.000A5.022
79.917%
5.022V6.284115.16V
1.500A7.514
79.530%
5.010V9.448115.16V
2.999A14.912
77.116%
4.972V19.337115.16V
0.056
0.098
0.314
0.376
0.410
0.456
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.227
61.022%
5.048V0.372230.31V
0.090A0.454
68.997%
5.046V0.658230.31V
0.550A2.768
77.535%
5.034V3.570230.31V
1.000A5.022
78.604%
5.022V6.389230.31V
1.500A7.515
79.423%
5.010V9.462230.30V
2.999A14.913
78.461%
4.972V19.007230.31V
0.019
0.033
0.154
0.229
0.279
0.351
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair CX550F RGB
115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 6/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 115V
Corsair CX550F RGB
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 7/16
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -115V
Corsair CX550F RGB
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 115V
Test #12V5V3.3V5VSB
2.749A1.979A1.983A0.997A54.954
1
12.132V5.053V3.329V5.016V65.66045.53°C115.15V
6.535A2.978A2.981A1.199A110.012
2
12.106V5.038V3.320V5.003V124.95446.49°C115.15V
10.670A3.482A3.488A1.403A165.003
3
12.085V5.027V3.312V4.990V184.76547.88°C115.15V
14.821A3.988A3.993A1.607A220.001
4
12.064V5.016V3.305V4.978V245.64448.64°C115.15V
18.643A5.001A5.008A1.813A274.989
5
12.041V5.000V3.296V4.963V308.04350.44°C115.15V
DC/AC
(Watts)
Efficiency
83.695%61210.7
88.042%63211.9
89.304%67416.0
89.561%73317.0
89.270%81022.2
Fan Speed
(RPM)
PSU Noise
(dB[A])
Corsair CX550F RGB
Temps
(In/Out)
40.39°C0.976
40.59°C0.976
41.53°C0.979
41.68°C0.985
42.25°C0.989
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
22.480A6.021A6.026A2.000A329.879
88.670%92125.7
12.018V4.984V3.287V4.949V372.03052.24°C115.15V
26.346A7.048A7.051A2.229A385.052
87.836%104530.8
11.992V4.967V3.277V4.934V438.37853.65°C115.15V
30.211A8.003A8.081A2.439A439.550
86.802%121736.2
11.967V4.950V3.267V4.920V506.38254.85°C115.14V
34.497A8.608A8.589A2.443A494.460
85.775%141339.5
11.942V4.937V3.260V4.912V576.46156.34°C115.14V
38.603A9.137A9.133A3.069A549.683
84.415%166743.9
11.916V4.925V3.251V4.887V651.17058.08°C115.15V
43.332A9.150A9.150A3.073A604.871
83.177%189646.8
11.889V4.919V3.245V4.880V727.21359.28°C115.14V
0.100A14.001A13.999A0.000A116.082
83.017%102729.9
12.114V4.923V3.282V4.999V139.82950.02°C115.17V
45.830A1.000A1.001A1.000A558.730
84.924%168044.6
11.902V5.011V3.281V4.965V657.91858.61°C115.14V
43.06°C0.989
43.55°C0.989
43.72°C0.990
44.58°C0.991
45.88°C0.992
46.62°C0.993
42.34°C0.973
45.15°C0.992
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 10/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair CX550F RGB
230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 11/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 230V
Corsair CX550F RGB
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 12/16
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -230V
Corsair CX550F RGB
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 13/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 230V
Test #12V5V3.3V5VSB
2.749A1.980A1.983A0.997A54.955
1
12.133V5.052V3.328V5.015V64.73444.28°C230.31V
6.535A2.978A2.983A1.200A110.018
2
12.107V5.036V3.319V5.001V122.98145.97°C230.31V
10.670A3.483A3.488A1.403A165.010
3
12.086V5.025V3.312V4.988V181.66247.31°C230.31V
14.820A3.988A3.996A1.608A220.007
4
12.065V5.015V3.304V4.976V241.10148.55°C230.31V
18.642A5.003A5.008A1.814A274.998
5
12.042V4.999V3.295V4.961V301.76550.44°C230.31V
DC/AC
(Watts)
Efficiency
84.894%61511.0
89.459%65012.6
90.834%69015.4
91.251%73016.9
91.130%80722.0
Fan Speed
(RPM)
PSU Noise
(dB[A])
Corsair CX550F RGB
Temps
(In/Out)
40.00°C0.834
40.95°C0.901
41.49°C0.934
41.50°C0.956
42.39°C0.965
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
22.481A6.023A6.028A2.000A329.886
90.736%91925.6
12.018V4.982V3.286V4.947V363.56551.76°C230.31V
26.346A7.051A7.054A2.230A385.063
90.139%104430.8
11.992V4.966V3.276V4.932V427.18753.73°C230.31V
30.217A8.000A8.082A2.440A439.572
89.369%121035.2
11.966V4.950V3.266V4.918V491.86154.00°C230.32V
34.505A8.609A8.593A2.444A494.485
88.598%141139.5
11.940V4.937V3.258V4.909V558.11955.32°C230.32V
38.613A9.140A9.137A3.071A549.699
87.629%162643.4
11.913V4.924V3.250V4.885V627.30657.29°C230.32V
43.345A9.152A9.155A3.075A604.898
86.628%187946.2
11.886V4.917V3.244V4.878V698.27259.31°C230.33V
0.100A14.001A13.999A0.000A116.068
84.519%100929.2
12.112V4.922V3.282V4.997V137.32751.08°C230.33V
45.829A1.000A0.999A1.000A558.614
88.227%162443.4
11.900V5.010V3.280V4.963V633.15657.51°C230.33V
42.57°C0.966
43.79°C0.968
43.93°C0.970
44.35°C0.971
45.49°C0.973
46.54°C0.975
42.87°C0.899
45.43°C0.974
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 15/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
Anex
Corsair CX550F RGB
CERTIFICATIONS 115V
CERTIFICATIONS 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 16/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS