Cornelius WCC700 User Manual

Page 1
IMI CORNELIUS INC.
One Cornelius Place Anoka. MN 55303-6234 Telephone (800) 238–3600 Facsimile (763) 422–3246
DUAL DF/ED 2XX LID KIT FOR THE FOLLOWING ICE
MAKERS: Cornelius Extreme 522 and Wilshire WCC 700
Dispenser DF/ED 2XX Kit Number 629087947
Components Qty
1. Cover 620043547 2
2. Lid Assembly (XAC 522 Icemaker) 620046064 1
3. Lid Assembly (WCC 700 Icemaker) 620046060 1
4. Mounting Bracket 22127 4
5. Screw, #8 SM 70217 20
6. RTV 50904 1
7. Label 91957 2
8. Instructions 620919550 1
9. Nut, Nylon 620701902 4
10. Washer, Nylon 620701903 4
11. Washer, Sealing 620701901 4
12. Ice Baffle 620037003 2
13. Gasket Strip 620505802 2
14. Binstat Kit 631500109 1
15. Plate, Top Cover 620044644 1
1. Unpack kit. Refer to Figures 1 & 2 for component detail.
2. Attach the ice baffles (item 12) to the lid assemblies (items 2 & 3) using the gasket strips, washers and acorn nuts provided (figure 1).
3. Replace the center–mounting bracket supplied with the dual merchandiser kit with the top cover plate sup­plied with this kit (item 15). Failure to do this will prevent the adapter kit from functioning properly.
4. Set the lid assembly onto the dispenser. Using the slotted holes on the side of the lid as a template, drill four (4) 9/64” diameter holes at the bottom of the slots (Figure 2).
Note: Use extreme care not to drill into the hopper. Use a drill stop to ensure that the drill bit does not penetrate deeper than ¼” past the sheet metal. Failure to do so could result in a hole in the hopper, great­ly reducing the efficiency of both the dispenser and ice maker.
5. Fasten the lid to the dispenser with four (4) #8 sheet metal screws (item 5), two on each side.
6. Seal the ice maker to the top of the dispenser as follows: A. Run beads of RTV (item 7) around the opening in the lid assembly and the inside of the perimeter of the
ice maker outline so that the ice maker will set on the RTV. Make sure that some RTV is applied inside
the nutserts on the lid assembly. B. Set the ice maker onto the lid and position it as required. C. Insert the thumbscrews (item 5) into the lid to attach the icemaker to the lid (Figure 3). D. Wipe away the excess RTV.
EIMI Cornelius Inc; 2001
November 30, 2001
Revision A
620919550
Page 2
7. Attach the mounting brackets (item 4) to the to the ice makers and lid assemblies with the the #8 sheet metal screws (item 5) (figure 2).
8. Follow the ice maker manufacturers instructions to complete the installation of the ice maker.
9. Install the bin–stat (item 14) per the instructions provided with that kit.
10. Install the covers (item 1) into the slots on the lid assemblies (figure 3).
11. Apply the label (item 6) on the front of the cover.
EIMI Cornelius Inc; 2001
November 30, 2001
Revision A
620919550
Page 3
13
10
11
9
SECTION W–W
SCALE 0.625
9
4X
10
4X
12
4X
11
2X
2X
13
12
EIMI Cornelius Inc; 2001
FIGURE 1. PARTS
November 30, 2001
Revision A
620919550
Page 4
DRILL ø 9/64 (.140) HOLES
USING BOTTOM OF SLOTTED HOLES AS A TEMPLA TE.
WCC700 ICEMAKER
EXTREME 522 ICEMAKER
VIEW X
SCALE 0.250
2X
1
2X
SEE FIGURE(S) 3a & 3b
4X
4
5
16X
7
3
SEAL ICEMAKER(S) TO
2
ITEM 2 AND 3 WITH ITEM 6 (RTV)
4X
5
REPLACE ITEM 5–ED2XX DUAL–LIGHTED
MERCHANDISER KIT WITH
P/N 620044644
EIMI Cornelius Inc; 2001
FIGURE 2. DISPENSER ASSEMBLY
November 30, 2001
SEE VIEW ”X”
Revision A
620919550
Page 5
WCC700 ICEMAKER
1
FIGURE 3a. CLOSED POSITION
SCALE 0.250
EXTREME 522 ICEMAKER
LID ASSEMBLY
WCC700 ICEMAKER
1
EXTREME 522 ICEMAKER
LID ASSEMBLY
EIMI Cornelius Inc; 2001
FIGURE 3b. OPEN POSITION
SCALE 0.250
November 30, 2001
Revision A
620919550
Loading...