Cornelius PR150, PR300, IP150 Installation Instructions Manual

PR150/300 and IP150 Separate Drain for Upper Drip Tray Installation Instructions
!
WAR NING:
INSTALLATION INSTRUCTIONS
PR150/300 & IP150 SEPARATE DRAIN FOR UPPER DRIP TRAY
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1. Raise and lock driptray assembly (see Figure 1).
Figure 1.
2. Clean out and dry driptray with a rag or paper towel, remove strainer if applicable (see Figure 2 and Figure 3).
Figure 2. Figure 3.
Revision Date: August 3, 2010 www.cornelius.com Revision: C © 2004-2010, IMI Cornelius Inc. - 1 - Publication Number: 629088497INS
PR150/300 and IP150 Separate Drain for Upper Drip Tray Installation Instructions
3. Remove insulation from driptray drain line assembly (see Figure 4).
Figure 4.
4. Cut PVC drain as shown in Figure 5. BE CAREFUL TO SECURELY HOLD DRAIN LINE TO AVOID DAMAGE TO UPPER DRIPTRAY!!!
5. Deburr edge of PVC and re-plumb and clamp with new flexible tube/clamp supplied in kit (see Figure 6). MAKE SURE THAT THE INSULATION COVERS ALL EXPOSED TUBING/CLAMP!
Figure 5.
6. Re-route new drain tube to floor drain. MAKE SURE THAT THERE ARE NO KINKS IN NEW DRAIN LINE!
7. Re-install driptray strainer if applicable.
8. Check driptray, fittings, and lines for leaks.
9. Lower upper driptray assembly.
Publication Number: 629088497INS - 2 - © 2004-2010, IMI Cornelius Inc.
Figure 6.
Loading...