Cornelius P-N 3626 User Manual

B
IMI CORNELIUS INC.
One Cornelius Place
Anoka MN 55303–6234
Telephone (800) 238–3600
Facsimile (612) 422–3246
UNIVERSAL 750 ICE BANK CONTROL
KIT P/N 3626
C
Step One
A. Remove the product lines and white washers.
Clip all poly ties.
B. Unscrew the control box. Disconnect the cord
and agitator motor electrical leads. Lay the control box over the side of the unit.
C
C. Remove the agitator motor. Unscrew the hex
nuts and screws holding the plate down. Re­move the plate.
D. Disconnect the tubes to the valves. Raise the
basket and remove the ice bank control holder by bending the top brackets.
P/N 18521100718/25/94
A
Step Two
B
P/N 3529
A. Snap the new ice bank control bulb holder
(P/N 3529) onto the second and third coil from the top.
B. Place the ice bank control bulb into the holder
and secure it with two poly ties (P/N 040056-000). Replace the basket and hook up the tubes to the valves.
B
Ice Bank Control P/N 33-5794-000
C
Red Lead P/N 3576
C. Connect the red and black wire leads to the ice
bank control as shown.
Black Lead P/N 3575
P/N 185211007 2 8/25/94