RF96PIRBMS - Z-WAVE PLUS MOTION SENSOR
The Motion Sensor is a Z-WaveTM enabled device which is fully compatible with any Z-WaveTM enabled network. The device can be set up in a Z-Wave network to communicate directly with other end devices such as switches or dimmers, or to connect to a Z-Wave controller such as Eaton’s Home Automation Hub or other Z-Wave certified controllers.
This product supports the S2 security protocol that uses encrypted Z-Wave Plus messages to communicate to other security-enabled Z-Wave Plus products. A security-enabled Z-Wave Plus Controller must be used in order to fully utilize the security features of this product.
The Motion Sensor is designed with two detecting sensors, Passive Infra-Red (PIR) sensor and ambient light sensor, in order to optimize its performance for both security and home automation applications. For security applications, the sensor will transmit a signal to a controller when any motion is detected within the device’s field of view which could trigger an alarm or some other notification. For home automation, the sensor can be used turn lights ON or OFF as someone enters or leaves a room or area. It includes a timeout timer that can automatically turn lights OFF when it no longer detects motion after a configurable amount of time. The light sensor allows the system to be configured to implement different actions based on the ambient light level (such day vs. night).
The Motion Sensor uses a CR123 3.0V Lithium battery, which under normal conditions, will have a battery life of up to 2 years. When the battery level drops to an unacceptable level, the sensor will emit a low battery message to the Z-Wave controller. When this occurs the batteries should be replaced as soon as possible
Product Overview
Quick Test
Prior to mounting the device, it is recommended that device is placed in test mode to find the optimal positioning of the sensor
1. If the rear cover is attached, remove the rear cover using a screwdriver.
2. With the rear cover detached, the tamper switch will be in the open position, and the unit will enter Test Mode.
3. During Test Mode, if movement is detected, the LED on the sensor will light up once implying the unit is working properly, and it will retrigger about every 5 seconds if motion is detected. During this mode, you can also test the range and positioning to make sure it is placed in an optimal location (see Choosing the Location section).
4. To exit the Test mode, simply press the Tamper switch for more than 10 seconds or simply replace the rear cover which causes the Tamper switch to be depressed.
5. During normal mode, when PIR is triggered, the red LED will not light up and retrigger time is based on set up value.
Mounting the Sensor
Choosing the location
The PIR Sensor is suitable for mounting in dry indoor locations only. The recommended position for a PIR Sensor is in the corner of a room mounted at a height between
5.9ft and 6.6ft. At this height, the sensor will have a maximum range of up to 30ft with a field of view of 120°, subject to the position for the sensor being set in position 5. (see FIGURES 1 & 2) The position of the PCB inside the sensor can be set to 5 different positions to adjust the range of the sensor. Setting the PCB in position 3 will reduce the range to approximately 20ft, with position 1 providing a range of approximately 10ft. The recommended position setting for the sensor is in position 5. The position should be set based on the desired range of the user.
30ft
Figure 1
Installing and Adding to Z-WaveTM Network
Auto Inclusion
The sensor supports Auto Inclusion feature where it will automatically enter Inclusion mode when first powered up after a factory reset.
1. Use a screwdriver to detach the rear cover.
Rear Cover
Fixing Screw
2. Put a Z-Wave Controller into inclusion mode.
3. Insert 1 CR123 3V battery to the battery compartment with the correct polarity. The LED on the device should turn ON.
The Inclusion process should be completed when the LED stops blinking.
4.
5. Do not refit the rear cover yet and proceed to the Testing section before mounting.
If Auto Inclusion fails, refer to the Troubleshooting section regarding Manual Inclusion.
Note:
Testing
Warm-Up
It will take approximately 2 minutes for the sensor to warm up after a battery is inserted. During this period the LED behind the lens will turn ON. When the red LED turns OFF, it implies that the warm-up procedure is completed and the sensor is ready for detection.
Note: This will not affect the Inclusion/Exclusion process. Note: After removing batteries, wait for 5 seconds to refit batteries.
Figure 2
When determining the mounting position for the sensor the following points should be considered to ensure trouble-free operation:
1. Do not locate the sensor facing a window or where it is exposed to or facing direct sunlight.
2. Do not locate the sensor near air vents.
3. Do not locate the sensor directly above a heat source, (e.g. fire, radiator, boiler, etc).
4. Do not locate the detector in a position where it is subject to excessive vibration
5. Where possible, mount the sensor in the corner of the room so that the logical path of a person would cut across the fan detection pattern. PIR sensors respond more effectively to movement across the device than to movement directly towards it. (FIGURE 3).
Less Sensitive More Sensitive
Figure 3
6. Ensure that the position selected for the PIR sensor is within effective range of the system, (refer to System Installation and Operating Manual).
Installation
Before mounting, ensure that the sensor PCB position is set to the correct position to provide the desired detection range. To adjust the range, simply slide the PCB up or down ensuring the position legs are aligned with the required position number marked on the board. The Motion Sensor can be mounted using either the provided dual-sided adhesive or screws.
For installation using dual-sided adhesive:
1. Remove one side of the adhesive cover and attach appropriately to the rear of the device. For corner mounting, it is recommended to cut the adhesive into two pieces and place on each angled side to ensure a better fit.
2. Remove the other side of the adhesive cover, place the device in its desired location, and apply pressure until the device is secure.
20ft
10ft
PCB Position Range
6.6 ft
1 10ft (3m)
3 20ft (6m)
5 30ft (9m)
For installation using screws:
1. Carefully drill out the required mounting holes in the rear cover using 3mm drill according to whether the unit is being mounted in a corner or against a flat wall. Note: Use the 1st mounting hole positions for corner mounting installation, and use the 2nd mounting hole positions for flat wall installation. (see FIGURE 4a & 4b)
2nd Mounting Hole Positions
1st Mounting Hole Positions
Corner Mounting
Figure 4a Figure 4b
2. Using the rear cover as a template, mark the positions of the fixing holes on the wall.
3. Fix the rear cover to the wall using the two 18mm No.4 screws and 25mm wall anchors, (a 5mm hole will be required for the wall anchors). Do not over-tighten the fixing screws as this may distort or damage the cover.
4. Fit the sensor onto the rear cover by placing the clips on the top edge into the rear cover. Push the lower edge of the sensor into place and refit the fixing screw in the bottom edge of the sensor to secure in position. Do not over-tighten the fixing screws as this may damage the casing. Once the device is mounted and installed in a Z-Wave network, ensure that motion is properly detected and the associated devices and/or controller are activated appropriately.
Programming Z-Wave Group
The sensor supports either one of two Z-Wave Association Groups:
Group 1: Association with 1 Controller node. Group 2: Association with 4 nodes (i.e. end devices such as switches or dimmers). This allows the
sensor to transfer commands directly to end devices without having to go through the controller. Group 1 commands:
• When the unit is powered up and is already a part of a Z-Wave network, the unit will send a Notification Report to the node in Group 1.
• When the unit senses motion, the unit will send a Notification Report to the nodes of Group 1. Once the movement is stopped, a Notification Report will be sent again to Group 1.
• When the sensor status changes, the unit will check its battery status simultaneously. When the battery level of the unit is low, the unit will emit a Battery report to the nodes of Group 1
• When performing Factory Reset the unit will send Device Reset Locally Notification to the node of Group 1. Group 2 commands:
• When the sensor is triggered, the unit will send BASIC_SET command which contains a value to the nodes of Group 2.
AGI (Association Group Information) Table
Group Profile
1 General
2 Control Basic Set PIR Control
Command Class & Command (List) N bytes
Battery Report, Notification Report Device Reset Locally Notification
Group Name
Lifeline
Notification
Event Type Event
The power is applied for the first time
PIR Trigger ON 0x07 0x08 0x00
PIR Trigger OFF 0x07 0x00 0x01 0x08
Tamper switch being pressed more than 10 seconds
Tamper switch being pressed more than 10 seconds and released
0x08 0x01 0x00
0x07 0x00 0x01 0x03
0x07 0x03 0x01
Event Parameters Length
Event Parameters
Battery
Battery Report (value) Description
20 ~ 100 Battery Level (%)
0xFF Low Battery
Wakeup Command Class
After it has been included into a Z-Wave network, the sensor will go to sleep but will send a Wakeup Notification Command periodically at preset interval to the controller. The Motion sensor will stay awake for at least 10 seconds and then go back to sleep to conserve battery life. The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class based on the range values below:
Minimum Wake Up Interval 600s (10 minutes)
Maximum Wake Up Interval 86400s (1 day)
Default Wake Up Interval 14400s (4 hours)
Wake Up Interval Step Seconds 600s (10 minutes)
Z-Wave’s Configuration Parameters
The following information is for someone that has some experience in setting up a Z-Wave system or someone that has computer software running a Z-Wave controller. Please get familiar with software of Z-Wave controller before getting started.
To save power for the battery, the motion sensor is normally in sleep mode. In order to wake the device up, press the tamper switch once. This will keep the device awake for 30 seconds indicated by the LED blinking every second. During this time, the user can change configuration parameters from the controller software. If more time is needed, continue pressing the tamper switch every 30 seconds.
1. Basic Set Level
1 of 2
The Basic Set Level determines the value that will be sent from the Basic Set command for
devices associated with Group 2. For a Binary Switch Device (e.g., receptacle or appliance module), it will be a simple ON command. For a Multilevel Switch Device (e.g., a dimmer), it will be set to the level set by this parameter.
Example: 1-99: ON (Binary Switch Device) Dim Level (Multilevel Switch Device)
Function Parameter Number Size Range Default
Basic Set level 1 1 1 ~ 99 99
Sensitivity Level (PIR sensor only)
2. In order to provide the best efficiency of the sensor, it is recommended to test the sensor with
movements from the farthest end of the coverage area at first time of use. If movements cannot be detected consistently parameter can be configured with the value of 1 through 10, where 1 means low sensitivity and 10 means high sensitivity.
Function Parameter Number Size Range Default
Sensitivity Level 3 1 1 ~ 10 6
3. Re-trigger Interval Setting (PIR sensor only) The Re-trigger Interval Setting determines the amount of time between when the sensor will re-
trigger a signal that motion has been detected. During this time, the sensor will not report motion even though motion may be detected. The time interval can be set between 5 secs to 3600 secs.
Function Parameter Number Size Range Default
Re-trigger Interval 4 2 5~3600 (sec) 180
movement
4. Lux Level The user can set a lux level percentage which determines when the light sensor will be activated.
If the lux level of ambient illumination falls below this percentage, and motion is detected, the sensor will emit a Z-Wave ON Command to the controller 100%.
Function Parameter Number Size Range Default
Lux Level 5 1 1 ~ 100% 20
On-Off
5.
Duration
The function of on-off duration setting will be useful if the detector is connected with a module
or lighting. The duration determines how long the module/lighting should stay ON. For instance, Lamp Module turns OFF 100 secs after it has been turned ON. This parameter can be configured with the value of 5 through 3600, where 5 means 5 second delay and 3600 means 3600 seconds of delay.
Function Parameter Number Size Range Default
ON-OFF Duration 6 2 5-3600 (sec) 15
triggered
Troubleshooting Guides
The table below lists the several steps involved when adding or removing the unit from the Z-Wave network.
Action/Status
No node ID The Z-Wave Controller does not allocate a node ID
Auto Inclusion The power is applied for the first time and no node
Manual Inclusion 1. Put the Z-Wave Controller into Inclusion mode
Exclusion 1. Put the Z-Wave Controller into Exclusion mode
Factory Reset (This procedure should only be used when the controller is inoperable)
* Failed or successful results in including/excluding the ID can be viewed on the Z-Wave Controller.
Note: If you are connecting this unit to a Z-wave Controller that utilizes the S2 security protocol, you may
be asked to enter a 5 digit Device Specific Key (DSK) that is unique to each unit by your controller. This can be found in one of two places:
• on the QR code label on the back of the unit
• on the insert card inside the packaging
, simply adjust the sensitivity level with Configuration Parameter #3. This
180
movement
(no response)
movement
. Percentage can be set between 1% to
turns on
Description LED indication
to the unit
ID has been stored in the module, or after execut­ing reset
2. Press the tamper switch 3 times within 1.5 seconds to put the unit into inclusion mode
2. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode
1. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode
2. Within 1 second of step 1, press the tamper switch again and hold until LED is off (about 5 seconds)
3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes
turns off
2-second ON, 2-second OFF for 2 minutes
2-second ON, 2-second OFF for 2 minutes
www.eaton.com/wiringdevices
www.eaton.com
EIS-0246-EFS (REV. B)
The table below lists typical problems encountered:
"FOR REFERENCE ONLY"
Symptoms
Cannot carry out inclusion and association
Cannot control the connected modules
The sensor is not working
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1: This device may not cause harmful interference, and 2: This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help. FCC CAUTION: Any changes or modifications not expressly approved by Eaton Wiring Devices could void the user’s authority to operate the equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage;
2. Ll’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
RADIATION EXPOSURE STATEMENT: This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with greater than 20cm between the radiator & your body.
EATON WIRING DEVICES LIMITED 2 YEAR WARRANTY
Eaton Wiring Devices warrants its switch to be free of defects in materials and workmanship in normal use and service for a period of two years from date of original purchase. THIS TWO (2) YEAR LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS IN DURATION IN EXCESS OF TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF EATON HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF EATON UNDER THIS WARRANTY.
To obtain warranty service for any properly installed Eaton switch that proves defective in normal use send the defective switch prepaid and insured to Quality Control Dept., Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; in Canada: Eaton Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. Eaton will repair or replace the defective unit, at its option. Eaton will not be responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse, abuse, improper installation, alteration, improper maintenance or repair of damage in shipment to Eaton. EATON SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE SWITCH, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL, CONTINGENT, OR CONSEQUENTIAL DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE SWITCH OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. THE EXCLUSIVE REMEDY FOR BREACH OF THE LIMITED WARRANTY CONTAINED HEREIN IS THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT AT EATON’S OPTION. IMPLIED WARRANTIES (IF ANY) INCLUDING, BUT NOT LIMITED TO IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABIITY, ARE LIMITED IN DURATION TO A PERIOD ENDING TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE. IN NO CASE SHALL EATON’S LIABILITY UNDER ANY OTHER REMEDY PRESCRIBED BY LAW EXCEED THE PURCHASE PRICE. Some states do not allow the exclusion or limitation of incidental or consequential damages or allow disclaimers or modifications of or limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Some Canadian provinces do not allow exclusion or variance of implied warranties so that some or all of the above limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state and province to province. Read enclosed instructions carefully. If you have any questions concerning use or care of this product, please write: Consumer Service Division, Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269.
Possible Cause Solution
1. Run out of battery power
2. Reverse battery polarity
3. Sensor is out of order
1. Run out of battery power
2. Sensor is out of order
1. Run out of battery power
2. Check if the mounting location is proper
3. Check if the sensor is mounted above a radiator or heater
4. Sensor is out of order
1. Replace a new battery
2. Refit the battery with correct polarity
3. Ensure the sensor is working properly
1. Replace a new battery
2. Ensure the sensor is working properly
1. Replace a new battery
2. Reposition its mounting location
3. Remove the source of interference or reposition its mounting location
4. Ensure the sensor is working properly
Specifications
Battery CR123 3.0V 1700mAh Lithium Battery
Battery Life 2 year*
RF Range Up to 100 ft line of sight
Warm Up Time About 2 minutes
PIR Detection Coverage Up to 30 ft x 120° (at 71 ft mounting height & 25°C)
Operating Frequency 908.42 MHz
FCC ID UH2-RF96PIRBMS
IC 4706C-RF96PIRBMS
* Specifications are subject to change without notice * measured at 10 triggers per day
FRANÇAIS
RF96PIRBMS– DÉTECTEUR DE MOUVEMENT Z-WAVE
Le détecteur de mouvement est un appareil utilisant la technologie Z-WaveMC entièrement compatible avec tout réseau Z-Wave directement avec d’autres dispositifs terminaux, comme un interrupteur ou un gradateur, ou se connecter directement à un contrôleur Z-Wave tel qu’un concentrateur de domotique domestique d’Eaton ou tout autre contrôleur certifié Z-Wave.
Ce produit prend en charge le protocole de sécuritéS2, qui se sert de messages chiffrés Z-Wave Plus pour communiquer avec les autres produits sécurisés de la gamme Z-Wave Plus. Pour profiter pleinement des fonctions de sécurité de ce produit, il faut utiliser un contrôleur sécurisé Z-Wave Plus.
Le détecteur de mouvement possède deux capteurs, un infrarouge passif et un de luminosité ambiant, ce qui améliore son efficacité pour les applications de sécurité et de domotique domestique. En tant qu’appareil de sécurité, le détecteur transmet un signal au contrôleur lorsqu’un mouvement pouvant déclencher une alarme ou une autre notification est détecté dans le champ de détection. En tant qu’appareil domotique domestique, le détecteur peut allumer ou éteindre les lumières si quelqu’un entre ou sort d’une pièce ou d’un périmètre. Une minuterie peut être réglée pour éteindre les lumières automatiquement après une certaine période de temps d’inactivité. Le capteur de luminosité du système donne accès à plusieurs configurations qui peuvent varier selon le niveau de luminosité (p.ex., jour ou nuit).
Le détecteur de mouvement est alimenté par une pile au lithium CR123A de 3V d’une durée de vie prévue de 2ans. Lorsque la pile est déchargée sous le seuil minimal, le détecteur transmet un avertissement au contrôleur. La pile doit être alors remplacée dès que possible.
MC
. Il peut être configuré dans un réseau Z-Wave afin de communiquer
Aperçu du produit
Mise en place du réseau et des appareils Z-Wave
Inclusion automatique
Ce détecteur prend en charge la fonction d’inclusion automatique, c’est-à-dire qu’il active automatiquement le mode d’inclusion à la première mise en marche suivant toute réinitialisation d’usine.
1. Utiliser un tournevis pour retirer le couvercle arrière.
Couvercle arrière
2. Mettre le contrôleur Z-Wave en mode d’inclusion.
3. Installer la pileCR123A de 3V dans le compartiment à pile en respectant la polarité. Le témoin à DEL de l’appareil devrait s’allumer.
4. Le processus d’inclusion devrait se terminer dès que le témoin à DEL cesse de clignoter.
5. Ne pas réinstaller le couvercle avant d’effectuer les essais décrits à la section suivante.
Remarque: Si l’inclusion automatique échoue, consulter la section de dépannage qui se rapporte àl’inclusion manuelle.
Essai
Mise en marche
Le détecteur sera fonctionnel environ 2minutes après qu’une pile est installée. Le témoin à DEL derrière la lentille s’allumera. Lorsque le témoin rouge s’éteint, la mise en marche est terminée et ledétecteur est prêt.
Remarque: Cela ne nuira pas au processus d’inclusion ou d’exclusion. Remarque: Attendre 5secondes après avoir enlevé la pile pour la remettre.
Vis de fixation
MC
Essai rapide
Avant d’installer l’appareil, il est conseillé de le configurer en mode d’essai pour trouver la position idéale du détecteur.
1. Retirer le couvercle arrière avec un tournevis s’il est fixé à l’appareil.
2. Si le couvercle arrière est enlevé, l’interrupteur de sécurité est allumé et l’appareil est en mode d’essai.
3. Si un mouvement est détecté en mode d’essai, le témoin à DEL du détecteur clignotera une fois pour indiquer que l’appareil fonctionne correctement. Il clignotera à nouveau toutes les 5secondes si un mouvement est détecté. Il est également possible de vérifier que l’appareil est installé à un endroit optimal en mettant sa portée et son positionnement à l’essai (voir la section Choisir l’emplacement).
4. Pour sortir du mode d’essai, appuyer 10secondes sur l’interrupteur de sécurité ou remettre lecouvercle.
5. En mode normal, lorsque le capteur infrarouge passif est en fonction, le témoin à DEL rouge n’est pas allumé et le délai entre les clignotements dépend du réglage de base.
Essai
Mise en marche
Le détecteur sera fonctionnel environ 2minutes après qu’une pile est installée. Le témoin à DEL derrière la lentille s’allumera. Lorsque le témoin rouge s’éteint, la mise en marche est terminée et ledétecteur est prêt.
Remarque: Cela ne nuira pas au processus d’inclusion ou d’exclusion. Remarque: Attendre 5secondes après avoir enlevé la pile pour la remettre.
Essai rapide
Avant d’installer l’appareil, il est conseillé de le configurer en mode d’essai pour trouver la position idéale du détecteur.
1. Retirer le couvercle arrière avec un tournevis s’il est fixé à l’appareil.
2. Si le couvercle arrière est enlevé, l’interrupteur de sécurité est allumé et l’appareil est en mode d’essai.
3. Si un mouvement est détecté en mode d’essai, le témoin à DEL du détecteur clignotera une fois pour indiquer que l’appareil fonctionne correctement. Il clignotera à nouveau toutes les 5secondes si un mouvement est détecté. Il est également possible de vérifier que l’appareil est installé à un endroit optimal en mettant sa portée et son positionnement à l’essai (voir la section Choisir l’emplacement).
4. Pour sortir du mode d’essai, appuyer 10secondes sur l’interrupteur de sécurité ou remettre lecouvercle.
5. En mode normal, lorsque le capteur infrarouge passif est en fonction, le témoin à DEL rouge n’est pas allumé et le délai entre les clignotements dépend du réglage de base.
Installation du détecteur
Choisir l’emplacement
Le détecteur est conçu pour être installé uniquement à l’intérieur et dans un endroit sec.
Il est conseillé d’installer le détecteur dans le coin d’une pièce à une hauteur entre 5,9pi et 6,6pi. Cette hauteur donne au détecteur une portée de détection de 30pi et un champ de détection de 120° en cinquième position (voir les figures1 et 2). La carte de circuit imprimé dans le détecteur peut être réglée selon cinq différentes positions pour ajuster la portée de détection. Latroisième position diminue la portée d’environ 20pi. En première position, la portée est d’environ 10pi. La position recommandée est la position 5. La position doit être réglée en fonctionde la portée désirée.
6,6pi
20 pi
Figure1
30 pi
Figure2
La position doit être réglée en suivant les directives ci-dessous pour que l’appareil fonctionne correctement:
1. Ne pas installer le détecteur devant une fenêtre ou à un endroit où il serait directement exposé aux rayons du soleil.
2. Ne pas installer le détecteur près des conduits d’aération.
3. Ne pas installer le détecteur directement au-dessus d’une source de chaleur comme un foyer, un radiateur ou une chaudière.
4. Ne pas installer le détecteur à un endroit où il serait sujet à des vibrations excessives.
5. Si possible, installer le détecteur dans le coin d’une pièce afin que le champ de détection soit traversé par une personne qui entrerait dans la pièce. Les mouvements qui traversent le champ de détection de l’appareil sont mieux détectés par les capteurs infrarouges passifs que ceux qui sont orientés directement vers l’appareil (FIGURE3).
Moins sensible Plus sensible
Figure3
6. Vérifier que la position du capteur infrarouge passif est à portée du système (consulter le guide d’utilisation et d’installation du système).
10 pi
Position de la carte
de circuit imprimé
1 10pi (3 m)
3 20pi (6 m)
5 30pi(9 m)
Portée
Installation
Avant d’installer l’appareil, vérifier que la carte de circuit imprimé est dans la position correspondant à la portée de détection désirée. Pour ajuster la portée, il suffit de déplacer la carte de circuit imprimé vers le haut ou le bas en s’assurant que les pattes de positionnement sont alignées avec le numéro indiqué sur la carte qui correspond à la position souhaitée. Le détecteur de mouvement peut être installé à l’aide des vis ou du ruban adhésif double-face fournis.
Installation avec le ruban adhésif double-face:
1. Retirer l’une des bandes de protection du ruban pour le fixer à l’arrière de l’appareil. Pour une installation dans un coin, couper le ruban en deux et le placer sur les côtés en angle pour installer correctement l’appareil.
2. Retirer l’autre bande de protection et installer l’appareil à l’emplacement désiré. Appuyer jusqu’à ce que l’appareil soit bien fixé.
Installation avec les vis:
1. Percer soigneusement les trous de montage requis dans le couvercle arrière à l’aide d’une mèche de 3mm, selon le type d’installation (dans un coin ou à plat au mur). Remarque: Utiliser la position n°1 des trous de montage pour une installation dans un coin et la position n°2 pour une installation à plat au mur (voir les FIGURES4a et 4b).
Position n°2 des trous de montage
Position n°1 des trous de montage
Installation en coin
Figure4a Figure4b
2. En utilisant le couvercle arrière comme modèle, marquer la position des trous de montage au mur.
3. Fixer le couvercle arrière au mur à l’aide des deux vis n°4 de 18mm et des deux ancrages au mur de 25mm (un trou de 5mm sera nécessaire pour la pose des ancrages). Ne pas trop serrer les vis de fixation, car cela pourrait déformer ou endommager le couvercle.
4. Poser le détecteur sur le couvercle arrière en veillant à y insérer les fixations supérieures. Pousser sur la partie inférieure du détecteur jusqu’à ce qu’il soit bien en place et visser la vis de fixation dans la partie inférieure du détecteur pour le fixer solidement. Ne pas trop serrer les vis de fixation, car cela pourrait endommager le boîtier. Une fois l’appareil fixé et installé dans un réseau Z-Wave, s’assurer que les mouvements sont bien détectés et que le contrôleur et les dispositifs connexes sont correctement activés.
Programmation Groupe Z-Wave
Le détecteur prend en charge l’un de ces deux groupes d’association Z-Wave:
Groupe1: association avec 1nœud du contrôleur. Groupe2: association avec 4nœuds (c.-à-d. avec des dispositifs terminaux, comme des
interrupteurs ou des gradateurs). Cela permet au détecteur de transférer des commandes directement aux dispositifs terminaux sans avoir à passer par le contrôleur. Commandes du groupe1:
•Lorsqu’elle est mise sous tension et qu’elle fait déjà partie d’un réseau Z-Wave, l’unité envoie un rapport de notification au nœud du groupe1.
•Lorsqu’elle détecte un mouvement, l’unité envoie un rapport de notification aux nœuds du groupe1. Lorsque le mouvement cesse, un autre rapport de notification est envoyé au groupe1.
•Lorsque l’état du détecteur change, l’unité vérifie l’état de la pile en même temps. Si le niveau de la pile est faible, l’unité envoie un rapport de pile aux nœuds du groupe1.
•Lorsqu’une réinitialisation d’usine est effectuée, l’unité envoie une notification de réinitialisation locale au nœud du groupe1. Commandes du groupe2:
•Lorsque le détecteur est activé, l’unité envoie une commande BASIC_SET contenant une valeur aux nœuds du groupe2.
Tableau d’information sur le groupe d’association (AGI)
Groupe Profil
1 Général
2 Contrôle Configuration de base
Classe de commandes et commandes (liste)– Noctets
Rapport de pile, rapport de notification de réinitialisation locale du dispositif
Nom du groupe
Câble de sécurité
Commande decapteur infrarouge passif
Notification
Événement Type Événement
Appareil mis sous tension pour la première fois
Déclenchement du capteur infrarouge passif activé
Déclenchement du capteur infrarouge passif désactivé
Interrupteur de sécurité enfoncé pendant plus de 10secondes
Interrupteur de sécurité enfoncé pendant plus de 10secondes, puis relâché
0x08 0x01 0x00
0x07 0x08 0x00
0x07 0x00 0x01 0x08
0x07 0x00 0x01 0x03
0x07 0x03 0x01
Durée des paramètres d’événement
Paramètres d’événement
Pile
Rapport de pile (valeur) Description
20 à 100 Niveau de charge de la pile (%)
0xFF Pile faible
www.eaton.com/wiringdevices
www.eaton.com
EIS-0246-EFS (REV. B)
Loading...
+ 2 hidden pages