INSTALLATION INSTRUCTIONS WARNING:
Turn OFF circuit breaker or remove fuse(s)
and test that power is off before wiring.
Never wire any electrical device with power turned on. Wiring
Switch with power on may cause permanent damage to Switch and void warranty.
If you are not sure about any part of these
instructions, please contact a licensed electrician.
IMPORTANT:
RF Switch will not work or will become damaged if wired incorrectly, and warranty will be voided. Refer to wiring instructions provided on reverse side.
CAUTION:
1. Use only with 120V AC 60 Hz.
2. Do not exceed maximum rating of the switch as indicated on the device.
3. Must be installed and used in accordance with electrical codes.
4. If a bare copper or green ground connection is not
available in the wallbox, contact a licensed electrician for installation.
5. Use only #14 or #12 copper wire rated for at least
75°C with these devices. Do not use with Aluminum wire.
NOTES:
1. The RF Master Switch is wired directly to the light fixture.
2. The RF Smart Switch is not compatible with standard 3-
way switches.
3. For Multi-location applications (3-Way or 4-Way) the RF
Smart Accessory Switch (RF9617) or a regular toggle switch could be used along with one RF Master Switch.
4. The RF Accessory Switch communicates via RF signals to
control the light from more than one location.
5. For multi-location control use RF Smart Dimmer Master
direct wired to the light along with RF Accessory (RF9642- Z). The RF Accessory does not require direct
connection to the light (use Association function).
Z-Wave Device Network Installation Instructions
1. This product may be added to a new or existing Z-Wave network. An Eaton Wiring Devices Z-Wave device has a blue LED, which will blink when the device is not included in a Z- Wave network. The LED stops blinking when the device is in a network.
2.To include this device in a Z-Wave network, select the command on your Z Wave controller for inclusion (Install, Add Device, Add Node, Include Device, etc.). Then press the device switch one time to include it in the network.
3.Based on the controller, the controller may ask to scan the QR code or manually enter 5 digit code under the QR code to install the device as a secured device
4. After the device is added to the network, the LED will stop blinking.
5.To exclude this device from a Z-Wave network, select the command on your Z-Wave controller for exclusion (Uninstall, Remove Device, Remove Node, Exclude Device, etc.). Then press the device switch one time to exclude it from the network. The LED will start blinking.
6. This product works with other Z-Wave products from different vendors and product categories as part of the same network.
OPERATION INSTRUCTIONS
RF9601 & RF9617
Parameter
Description
Value
1
Delayed Off Time
0 to 255
2
Panic On Time
0 to 255
3
Panic Off Time
0 to 255
5
Power Up State
1=OFF 2= ON 3 = Last State
6
Panic Mode Enable
0=Off 1=On
13
BLUE LED Brightness
Level while the switch
is ON
0-4
14
BLUE LED Brightness
Level while the switch
is OFF
0-4
Press once to turn lights ON
Press again to turn lights OFF.
When lights are ON, press and hold for 2 seconds until the blue
LED blinks. After the preset delay, the lights will turn OFF (up to 4 minutes).
Change LED Indicator brightness This feature allows the change of the brightness of the LED indicator. There are 5 levels (Off to Full brightness) to change the LED indicator brightness level either while the device is ON or OFF state.
Changing the LED indicator brightness when
the device is on ON state
o Turn the light on o Press and hold the On/Off button for
15 seconds till the LED indicator flashes for the second time.
o Release the button o Single tap the ON/OFF button to
change the LED indicator level (it will cycle between the five levels)
o Once the brightness level is chosen
then double tap on the On/Off button and this value will be saved
Changing the LED indicator brightness when
the device is on OFF state
Local Reset The device could be reset locally which means to be excluded from its network and restore the default. Before leaving the network the device will send a notification to the controller indicating its departure.
Turn on the device Press and hold for 20 second till the LED
flashes
Release the button LED will flash fast and then LED will blink
indicating the switch is not part of the network
o Turn the light Off o Press and hold the On/Off button for
15 seconds till the LED indicator flashes.
o Release the button o Use the dim button (UP/DOWN) to
change the LED indicator level (it will cycle between the five levels)
o Once the brightness level is chosen
then double tap on the On/Off button and this value will be saved
Configuration parameters
Loading...