PACKAGING CONTENTS/CONTENIDO DEL PAQUETE

A. Motion detector

B. Coverplate gasket

C. (2)

Lampholder gaskets

and light fixture

Junta de la placa

(2)

Juntas obturadoras

 

Detector de

de cubierta

del receptáculo

movimiento y

 

 

 

artefacto de luz

 

 

 

E. (3) Wire nuts

F. Color-matched

(3) Conectores

center hole plug

 

de cable

Tapón para agujero

 

central de color

 

coincidente

CMS185D (Bronze)

CMS185DW (White)

D.(2) #6 and (2) #8 mounting screws (use the size that fits your junction box)

(2) Tornillos #6 y (2) tornillos #8 de montaje (utilice el tamaño que mejor se adecue a su caja de conexión)

G. Mounting plate

H. Mounting bracket

screw

Soporte de montaje

Tornillo para la

 

placa de montaje

 

ENGLISH

ITEMS REQUIRED

(Purchase separately)

Phillips screwdriver

Outdoor weatherproof silicone caulking

(2) 100 watt (MAX) PAR 38 floodlight bulbs

NOTE: This fixture was designed to work with up to 150 watt maximum PAR halogen flood bulbs. For improved energy efficiency, lower wattage PAR halogen flood bulbs may be used. Compact Fluorescent (CFL) bulbs contain electronics which may interfere with the motion sensing function of your fixture and are not recommended. To meet ENERGY STAR® requirements, maximum total lamp wattage can not exceed 250 watts.

HOW IT WORKS

PIR does a good job of detecting lateral motion across the 180° range of detection. Precision Plus Doppler Radar™ does an excellent job detecting motion towards and away from the unit.

Both systems combined provide enhanced accuracy and complete coverage within the detection range. Motion from any direction will

trigger your floodlight—even during hot or cold temperature extremes.

IMPORTANT SAFETY INSTRUCTIONS

Up to 70 feet

180 degrees

When using product, basic precautions should always be followed, including the following:

Read and follow these instructions.

Heed all warnings, including below warnings AND those included on product.

Save these instructions and warnings.

For outdoor use only.

cETLus LISTED for wet location.

Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.

Disassembling your fixture will void the warranty.

Your fixture is prewired and preassembled for easy installation.

WARNING

Bulb gets HOT quickly!

The bulb and fixture get extremely hot during use. Disconnect power and allow fixture to cool before changing bulb or handling fixture.

Fixture should be installed by persons with experience in household wiring or by a qualified electrician. The electrical system, and the method of electrically connecting the fixture to it, must be in accordance with the National Electrical Code and local building codes.

Always replace bulb with the same wattage or lower wattage than marked. Installing a bulb of a higher wattage could create a fire hazard. Use of a higher wattage bulb will void the warranty. (Maximum 150 watt PAR halogen bulb.)

CAUTION

Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids the warranty.

Fixture must be mounted to a grounded recessed junction box marked for use in wet locations.

Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.

Do not allow sensor head to touch light housing – maintain at least 1 inch space between fixture and sensor.

Keep away from flammable objects. Do not position fixture within 2 inches of any combustible materials.

• For proper operation and protection against damage, the motion sensor head adjustment knobs must be facing the ground.

MINIMUM 90° C SUPPLY CONDUCTORS.

Do not use this apparatus near water.

Clean only with a dry cloth.

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.

Only use attachments/accessories specified by the manufacturer.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and

(2) this device must accept any interference received, including interference that

may cause undesired operation. Under Part 15­of the FCC Rules, any changes or modifications to the motion detector described in this instruction sheet that are not expressly approved by Cooper Lighting, LLC could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio

frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna.

-Increase the separation between the equipment and receiver.

-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

-Consult the dealer or an experienced radio/TV technician for help.

WARNING: FCC Regulations state that any unauthorized changes or

modifications to this equipment not expressly approved by the manufacturer could void the user’s authorization to operate this equipment.